Engineering PapersSearch

Engineering topics

Komhyr, W. D.

Publications and source records attributed to Komhyr, W. D..

Stratospheric Ozone Intercomparison Campaign (STOIC) 1989: Overview

The NASA Upper Atmosphere Research Program organized a Stratospheric Ozone Intercomparison Campaign (STOIC) held in July-August 1989 at the Table Mountain Facility (TMF) of the Jet Propulsion Laboratory (JPL). The primary instruments participating in this campaign were several that had been developed by NASA for the Network for the Detection of Stratospheric Change: the JPL ozone lidar at TMF, the Goddard Space Flight Center trailer-mounted ozone lidar which was moved to TMF for this comparison, and the Millitech/LaRC microwave radiometer. To assess the performance of these new instruments, a validation/intercomparison campaign was undertaken using established techniques: balloon ozonesondes launched by personnel from the Wallops Flight Facility and from NOAA Geophysical Monitoring for Climate Change (GMCC) (now Climate Monitoring and Diagnostics Laboratory), a NOAA GMCC Dobson spectrophotometer, and a Brewer spectrometer from the Atmospheric Environment Service of Canada, both being used for column as well as Umkehr profile retrievals. All of these instruments were located at TMF and measurements were made as close together in time as possible to minimize atmospheric variability as a factor in the comparisons. Daytime rocket measurements of ozone were made by Wallops Flight Facility personnel using ROCOZ-A instruments launched from San Nicholas Island. The entire campaign was conducted as a blind intercomparison, with the investigators not seeing each others data until all data had been submitted to a referee and archived at the end of the 2-week period (July 20 to August 2, 1989). Satellite data were also obtained from the Stratospheric Aerosol and Gas Experiment (SAGE 2) aboard the Earth Radiation Budget Satellite and the Total Ozone Mapping Spectrometer (TOMS) aboard Nimbus 7. An examination of the data has found excellent agreement among the techniques, especially in the 20- to 40-km range. As expected, there was little atmospheric variability during the intercomparison, allowing for detailed statistical comparisons at a high level of precision. This overview paper summarizes the campaign and provides a 'road map' to subsequent papers in this issue by the individual instrument teams which will present more detailed analysis of the data and conclusions.

Margitan, J. J.

Results of international Dobson spectrophotometer calibrations at Arosa, Switzerland, 1990

An international comparison of Dobson ozone spectrophotometers, organized and partially funded by the World Meteorological Organization (WMO), was held at the Lichtklimatisches Observatorium (LKO) in Arosa, Switzerland, July-August 1990. Countries participating with a total of 18 Dobson instruments were Belgium, Czechoslovakia, Denmark, Germany, Greece, Hungary, Iceland, Norway, Poland, Portugal, Rumania, Spain, Switzerland, the United Kingdom, the United States, and the United Soviet Socialist Republics. The reference standard instrument for the comparison was U.S.A. Secondary Standard Dobson Spectrophotometer 65 maintained by the NOAA Climate and Monitoring and Diagnostics Laboratory, Boulder, Colorado. The mean difference in ozone obtained with the Dobson instruments relative to Dobson instrument 65, calculated from ADDSGQP observations in the air mass range 1.15-3.2, was minus 1.0 plus or minus 1.2 (1 sigma) percent. The WMO Standard Brewer Spectrometer 39 also participated. In the mean, the Brewer instrument measured 0.6 plus or minus 0.2 (1 sigma) percent more ozone than did Dobson instrument 65. Results are presented, also, of ozone vertical profile measurements made with the Dobson instruments, two Brewer spectrometers, a LIDAR, a balloon ozonesonde flown from Hohenpeissenberg, Germany, and balloon ozonesondes flown from Payerne, Switzerland.

Grass, R. D.

Ozone vertical profile changes over South Pole

Important changes in the ozone vertical profile over South Pole, Antarctica have occurred both during the recent period of measurements, 1986-1991, and since an earlier set of soundings was carried out from 1967-1971. From the onset of the 'ozone hole' over Antarctica in the early 1980s, there has been a tendency for years with lower spring ozone amounts to alternate with years with somewhat higher (although still depleted) ozone amounts. Beginning in 1989 there have been three consecutive years of strong depletion although the timing of the breakdown of the vortex has varied from year to year. Comparison of the vertical profiles between the two periods of study reveals the dramatic decreases in the ozone amounts in the stratosphere between 15-21 km during the spring. In addition, it appears that summer values are also now much lower in this altitude region.

Oltmans, S. J.

An automated optical wedge calibrator for Dobson ozone spectrophotometers

The Dobson ozone spectrophotometer measures the difference of intensity between selected wavelengths in the ultraviolet. The method uses an optical attenuator (the 'Wedge') in this measurement. The knowledge of the relationship of the wedge position to the attenuation is critical to the correct calculation of ozone from the measurement. The procedure to determine this relationship is time-consuming, and requires a highly skilled person to perform it correctly. The relationship has been found to change with time. For reliable ozone values, the procedure should be done on a Dobson instrument at regular intervals. Due to the skill and time necessary to perform this procedure, many instruments have gone as long as 15 years between procedures. This article describes an apparatus that performs the procedure under computer control, and is adaptable to the majority of existing Dobson instruments. Part of the apparatus is usable for normal operation of the Dobson instrument, and would allow computer collection of the data and real-time ozone measurements.

Evans, R. D.

The latitudinal distribution of ozone to 35 km altitude from ECC ozonesonde observations, 1982-1990

Electrochemical concentration cell (ECC) ozone-sonde observations, made in recent years at ten stations whose locations range from the Arctic to Antarctica, have yielded a self-consistent ozone data base from which mean seasonal and annual latitudinal ozone vertical distributions to 35 km have been derived. Ozone measurement uncertainties are estimated, and results are presented in the Bass-Paur (1985) ozone absorption coefficient scale adopted for use with Dobson ozone spectrophotometers January 1, 1992. The data should be useful for comparison with model calculations of the global distribution of atmospheric ozone, for serving as apriori statistical information in deriving ozone vertical distributions from satellite and Umkehr observations, and for improving the satellite and Umkehr ozone inversion algorithms. Attention is drawn to similar results based on a less comprehensive data set published in Ozone in the Atmosphere, Proceedings of the 1988 Quadrennial Ozone Symposium where errors in data tabulations occurred for three of the stations due to inadvertent transposition of ozone partial pressure and air temperature values.

Komhyr, W. D.

Ozone loss in the lower stratosphere over the United States in 1992-1993: Evidence for heterogeneous chemistry on the Pinatubo aerosol

Ozone profiles obtained at Boulder, Colorado and Wallops Island, Virginia indicate that ozone was about 25% below normal during the winter and spring of 1992-93 in the 12-22 km region. This large ozone reduction in the lower stratosphere, though sometimes partially compensated by higher than normal ozone above 24 km, was responsible for the low total column ozone values observed across the United States during this period. Normal temperatures throughout the low ozone region suggest that transport-related effects are probably not the most important cause of the ozone deficits. This region of low ozone at Boulder corresponds closely with the location of the enhanced H2SO4/H2O aerosol from the Pinatubo eruption of 1991 as measured near Boulder and at Laramie, Wyoming. Trajectory analyses suggest that except at low altitudes in spring, air parcels on the days of the ozone measurements generally arrived at Boulder from higher latitude, although seldom higher than 60 deg N, and hence may have been subjected to heterogeneous chemical processing on the surface of Pinatubo aerosol droplets resulting in chlorine-catalyzed ozone destruction, a process which is believed to be more effective under the lower winter temperatures and sunlight levels of higher latitudes.

Hofmann, D. J.

Long-term changes in the total ozone mapping spectrometer relative to world primary standard Dobson spectrometer 83

The stability of the calibration of the Nimbus 7 solar backscatter UV (SBUV) and total ozone mapping spectrometer (TOMS) instruments by comparing their ozone measurements with those made by a single, very stable Dobson instrument: the world primary standard Dobson spectrometer number 83. Measurements of ozone made with instrument 83 at Mauna Loa observatory in eight summers between 1979 and 1989 were compared with coincident TOMS ozone measurements. The comparison shows that relative to instrument 83, ozone measured by TOMS (and SBUV) was stable between 1979 and approximately 1983, had decreased by 3 percent by 1986, and had decreased by almost 7 percent by 1989. A similar time dependence is seen when data from an ensemble of 39 Dobson stations throughout the world is compared with TOMS over the period 1979-1987. The most likely reason for the relative drift is that the diffuser plate used by both SBUV and TOMS to measure solar flux has suffered an uncorrected wavelength-dependent degradation, with most of the degradation occurring after 1983. The recently released version 6 TOMS data, corrected using the internal 'pair justification' technique, show almost no drift relative to Dobson instrument 83. Accurate measurements of long-term global ozone change will require a coherent system incorporating both ground-based and satellite-based ozone measurements.

Mcpeters, Richard D.

Atmospheric ozone at South Pole, Antarctica, in 1986

Results of NOAA's measurements of the ozone vertical distributions at the South Pole and of the annual course of total ozone, conducted in 1986 with balloon-borne electrochemical concentration cell (ECC) ozonesondes and a Dobson spectrophotometer, are described. The major finding was that the stratospheric ozone decreases abruptly between September 20 and October 15, with the bulk decrease occurring between 12 and 21 km. In this period, the column ozone and ozone volume mixing ratio at 16 km (the altitude of the normal ozone maximum at South Pole) decreased by 78 percent, and column ozone between 12 and 21 km decreased by 50 percent. The results of these measurements are compared with data obtained in 1971, and the changes observed in the ozone vertical distributions and in the temporal variations of atmospheric ozone are discussed.

Komhyr, W. D.

Total ozone, ozone vertical distributions, and stratospheric temperatures at South Pole, Antarctica, in 1986 and 1987

Seventy-six electrochemical cell (ECC) ozonesondes were flown at South Pole, Antarctica, during 1987 in a continuing program to document year-round changes in Antarctica ozone that are dynamically and photochemically induced. Dobson spectrophotometer total ozone observations were also made. For the twilight months of March and September when Dobson instrument observations cannot be made at South Pole, total ozone amounts were deduced from the ECC ozonesonde soundings. ECC sonde total ozone data obtained during the polar night (April to August), supplemented the sparse total ozone data obtained from Dobson instrument moon observations. Similar ozone profile and total ozone observations were made at South Pole in 1986.

Komhyr, W. D.

Dobson ozone spectrophotometer modification.

Description of a modified version of the Dobson ozone spectrophotometer in which several outdated electronic design features have been replaced by circuitry embodying more modern design concepts. The resulting improvement in performance characteristics has been obtained without changing the principle of operation of the original instrument.

Komhyr, W. D.