Engineering Papers⌕ Search

Engineering topics

Kolodziejczak, Jeffery

Publications and source records attributed to Kolodziejczak, Jeffery.

Calibrating the IXPE Observatory from Ground to Space

The Imaging X-ray Polarimetry Explorer (IXPE) will be the next SMEX mission launched by NASA in 2021 in collaboration with the Italian Space Agency (ASI). IXPE will perform groundbreaking measurements of imaging polarization in X-rays for a number of different classes of sources with three identical telescopes, finally (re)opening a window in the high energy Universe after more than 40 years since the first pioneering results. The unprecedented sensitivity of IXPE to polarization poses peculiar requirements on the payload calibration, e.g. the use of polarized and completely unpolarized radiation, both on ground and in orbit, and can not rely on a systematic comparison with results obtained by previous observatories. In this paper, we will present the IXPE calibration plan, describing both calibrations which will be performed on the detectors at INAF-IAPS in Rome (Italy) and the calibration on the mirror and detector assemblies which will be carried out at Marshall Space Flight Center in Huntsville, Alabama. On orbit calibrations, performed with calibrations sources mounted on a filter wheel and placed in front of each detector when necessary, will be presented as well.

X-ray astronomy Polarimetry Calibratio↗

Active Full-Shell Grazing-Incidence Optics

MSFC has a long history of developing full-shell grazing-incidence x-ray optics for both narrow (pointed) and wide field (surveying) applications. The concept presented in this paper shows the potential to use active optics to switch between narrow and wide-field geometries, while maintaining large effective area and high angular resolution. In addition, active optics has the potential to reduce errors due to mounting and manufacturing lightweight optics. The design presented corrects low spatial frequency error and has significantly fewer actuators than other concepts presented thus far in the field of active x-ray optics. Using a finite element model, influence functions are calculated using active components on a full-shell grazing-incidence optic. Next, the ability of the active optic to effect a change of optical prescription and to correct for errors due to manufacturing and mounting is modeled.

Full-shell↗

The Imaging X-Ray Polarimetry Explorer (IXPE)

The Imaging X-ray Polarimetry Explorer (IXPE) is an exciting international collaboration for a scientific mission that dramatically brings together the unique talents of the partners to expand observation space by simultaneously adding polarization measurements to the array of source properties currently measured (energy, time, and location). IXPE uniquely brings to the table polarimetric imaging. IXPE will thus open new dimensions for understanding how X-ray emission is produced in astrophysical objects, especially systems under extreme physical conditions-such as neutron stars and black holes. Polarization singularly probes physical anisotropies-ordered magnetic fields, aspheric matter distributions, or general relativistic coupling to black-hole spin-that are not otherwise measurable. Hence, IXPE complements all other investigations in high-energy astrophysics by adding important and relatively unexplored information to the parameter space for studying cosmic X-ray sources and processes, as well as for using extreme astrophysical environments as laboratories for fundamental physics.

X-ray astronomy x-ray polarimetry↗

Mounting for Fabrication, Metrology, and Assembly of Full Shell Grazing Incidence Optics

Future x-ray telescopes will likely require lightweight mirrors to attain the large collecting areas needed to accomplish the science objectives. Understanding and demonstrating processes now is critical to achieving sub-arcsecond performance in the future. Consequently, designs not only of the mirrors but of fixtures for supporting them during fabrication, metrology, handling, assembly, and testing must be adequately modeled and verified. To this end, MSFC is using finite-element modeling to study the effects of mounting on full-shell grazing-incidence mirrors, during all processes leading to flight mirror assemblies. Here we report initial results of this study.

Roche, Jacqueline M.↗

Methods for Detection and Correction of Sudden Pixel Sensitivity Drops

PDC 8.0 includes implementation of a new algorithm to detect and correct step discontinuities appearing in roughly one of every twenty stellar light curves during a given quarter. An example of such a discontinuity in an actual light curve is shown in fig. 1. The majority of such discontinuities are believed to result from high-energy particles (either cosmic or solar in origin) striking the photometer and causing permanent local changes (typically -0.5% in summed apertures) in quantum efficiency, though a partial exponential recovery is often observed. Since these features, dubbed sudden pixel sensitivity dropouts (SPSDs), are uncorrelated across targets they cannot be properly accounted for by the current detrending algorithm. PDC de-trending is based on the assumption that features in flux time series are due either to intrinsic stellar phenomena or to systematic errors and that systematics will exhibit measurable correlations across targets. SPSD events violate these assumptions and their successful removal not only rectifies the flux values of affected targets, but demonstrably improves the overall performance of PDC de-trending.

Kolodziejczak, Jeffery↗

Gravity Probe B Timing System and Roll Phase Determination

An oven-controlled crystal oscillator at 16.368 MHz provides clock signals to all GP-B components and synchronizes the data collection, transmission and processing. The sampled science data signals are stamped with the vehicle time, a counter of the 10Hz data strobe divided down from the clock. The GPS receiver supplies an external reference for time transfer between the vehicle time and coordinated universal time. Ground and space flight tests show the time transfer error is within 1 microsecond. The time latency between the effective sample time of science signals and the stamped vehicle time is verified to 1 ms in the ground tests. The GP-B satellite is controlled to roll with a period of 77.5 sec about an axis along the direction to the guide star to average out the disturbance torques fixed to the body of the satellite and reduce the gyroscope readout noise. The roll phase is determined on the ground to high accuracy with the telemetry data from two star trackers and used in the data analysis to separate the drifts of gyroscope spin axes in the orbital plane and perpendicular to the orbital plane. The flight data shows that the roll phase is controlled to within 40 arcsec with a measurement uncertainty of 7 arcsec.

Jie, Li↗

Satellite Test of the Equivalence Principle, Overview and Progress

An overview of STEP, the Satellite test of the Equivalence Principle will be presented. This space-based experiment will test the Universality of free fall and is designed to advance the present state of knowledge by over 5 orders of magnitude. The international STEP collaboration is pursuing a development plan to improve and verify the technology readiness of key systems. We will discuss recent advances with an emphasis on accelerometer fabrication and test. The transfer of critical technologies successfully demonstrated in flight by the Gravity Probe B mission will be described.

Kolodziejczak, Jeffery↗

Lessons from the GP-B Experience for Future Fundamental Physics Missions in Space

Gravity Probe B launched in April 2004 and completed its science data collection in September 2005, with the objective of sub-milliarcsec measurement of two General Relativistic effects on the spin axis orientation of orbiting gyroscopes. Much of the technology required by GP-B has potential application in future missions intended to make precision measurements. The philosophical approach and experiment design principles developed for GP-B are equally adaptable to these mission concepts. This talk will discuss GP-B's experimental approach and the technological and philosophical lessons learned that apply to future experiments in fundamental physics. Measurement of fundamental constants to high precision, probes of short-range forces, searches for equivalence principle violations, and detection of gravitational waves are examples of concepts and missions that will benefit kern GP-B's experience.

Kolodziejczak, Jeffery↗

AM03-AM121-115 Hard X-Ray Optics Development at MSFC

We have developed the electroformed-nickel replication process to enable us to fabricate light-weight hard-x-ray region. Two projects currently utilizing this technology are the production of over 250 r from 5 to 10 cm, for our HERO balloon payload, and 15- and 23-cm-diameter shells for a prototype module. The challenge for the former is to fabricate, mount, align and fly a large number of high-r constraints of a modest budget. For the latter, the challenge is to maintain high angular resolution shell thicknesses (100 micron) which make the shells extremely sensitive to electroforming stresses process does not degrade the ultra-smooth surface finish (approx. 3 A required for eventual multilayer c on these two programs.

Ramsey, Brian↗