Engineering PapersSearch

Engineering topics

Koch, Timothy

Publications and source records attributed to Koch, Timothy.

The Advanced Microwave Radiometer – Climate Quality (AMR-C) Instrument for Sentinel-6

The Advanced Microwave Radiometer – Climate Quality (AMR-C) is designed to measure the path delay due to atmospheric water vapor along Sentinel-6 altimeter path over one decade. The AMR-C receiver is based on heritage from previous AMR instruments with the addition of a THz-frequency radiometer, the High Resolution Microwave Radiometer (HRMR), for improved coastal zone accuracy and a Supplemental Calibration System (SCS) to meet level 3 requirements that the path delay error due to the altimeter-derived sea surface height be less at 0.8 cm and the path delay stability be maintained to 0.7 mm averaged over a 1-year time period.

Maiwald, Frank

The Deep Space Atomic Clock Mission

The Deep Space Atomic Clock (DSAC) mission will demonstrate the space flight performance of a small, low-mass, high-stability mercury-ion atomic clock with long term stability and accuracy on par with that of the Deep Space Network. The timing stability introduced by DSAC allows for a 1-Way radiometric tracking paradigm for deep space navigation, with benefits including increased tracking via utilization of the DSN's Multiple Spacecraft Per Aperture (MSPA) capability and full ground station-spacecraft view periods, more accurate radio occultation signals, decreased single-frequency measurement noise, and the possibility for fully autonomous on-board navigation. Specific examples of navigation and radio science benefits to deep space missions are highlighted through simulations of Mars orbiter and Europa flyby missions. Additionally, this paper provides an overview of the mercury-ion trap technology behind DSAC, details of and options for the upcoming 2015/2016 space demonstration, and expected on-orbit clock performance.

autonomy

Cosmic background radiation anisotropy at degree angular scales - Further results from the South Pole

We report further results from the University of California at Santa Barbara program to measure anisotropy in the cosmic background radiation at angular scales near 1 deg, an angular range corresponding to the largest scales where structure is observed. A 30 GHz high electron mobility transistor amplifier-based detector was coupled to the Advanced Cosmic Microwave Explorer, a 1 m off-axis Gregorian telescope. We present data that represent 64 of the total of 500 hr acquired with this system during the 1990-1991 season. The data have a statistical error of 13.5/micro-K/pixel. These are the smallest error bars of any data set of this type published to date. The data contain a significant signal with a maximum likelihood Delta T/T roughly 1 x 10 exp -5. The spectrum of the signal seen in slightly less than 2 sigma away from the thermal spectrum expected of primordial fluctuations in the cosmic background radiation. If the source of the fluctuations is primordial, then the data are consistent with cold dark matter scenarios when normalized to the large-scale anisotropy observed by COBE, while if the origin of the signal is foreground emission or another form of contaminant then the data are marginally inconsistent with standard cold dark matter models. In either case, the data are sufficiently sensitive to provide a crucial test of many models.

Schuster, Jeffrey

A degree-scale measurement of anisotropy of the cosmic background radiation

We report on the preliminary result of a search for anisotropy in the cosmic background radiation (CBR) with a beam size of about 1.5 deg FWHM over a wavelength range of 8-12 mm. The system operated successfully for 500 hr at the South Pole during the 1990-1991 austral summer. The data from one region, representing 25 hr after editing, are presented here. A strong signal is present in the lower frequency channels with a spectrum unlike CBR fluctuations, and is probably due to foreground emission. The highest frequency channel has the smallest contribution from this signal and has been used to set a 95-percent confidence level upper limit of not greater than 1.4 x 10 exp -5 for fluctuations with a Gaussian autocorrelation function at a coherence angle of 1.2 deg. This is significantly more sensitive than previous experiments at this angle scale.

Gaier, Todd