Engineering PapersSearch

Engineering topics

Koch, D. G.

Publications and source records attributed to Koch, D. G..

A Performance Comparison for Two Versions of the Vulcan Photometer

Analysis of the images produced by the first version (V1) of the Vulcan photometer indicated that two major sources of noise were sky brightness and image motion. To reduce the effect of the sky brightness, a second version (V2) with a longer focal length and a larger format detector was developed and tested. The first version consisted of 15-centimeter (cm) focal length, F/1.5 Aerojet Delft reconnaissance lens, and a 2048 x 2048 format front-illuminated charged coupled device (CCD) with 9 microns micropixels (Mpixels). The second version used a 30-cm focal length, F/2.5 Kodak AeroEktar lens, and a 4096 x 4096 format CCD with 9 micro pixels. Both have a 49-square-degree field of view (FOV) but the area of the sky subtended by each pixel in the V2 version is one-fourth that of the V1 version. This modification substantially reduces the shot noise due to the sky background and allows fainter stars to be monitored for planetary transits. To remove the data gap and consequent signal-level change caused by flipping the photometer around the declination axis and to reduce image movement on the detector, several other modifications were incorporated. These include modifying the mount and stiffening the photometer and autoguider structures to reduce flexure. This paper compares the performance characteristics of each photometer and discusses tests to identify sources of systematic noise.

Borucki, W. J.

Scientific Issues Addressed by the Kepler Mission

The Kepler Mission uses a wide field-of-view telescope to photometrically monitor 100,000 main-sequence stars for evidence of planetary transits. Because of the large number of stars monitored and because the mission is designed with a precision (0.002%) sufficient to readily recognize Earth-size planets transiting solar-like stars, several hundred Earth-size planets should be found. Based on the the Dopper velocity observations that find 2% of the main-sequence stars have Jupiter-size planets in short-period orbits, the Kepler mission is also expected to detect about 2000 giant planets. Several questions about the association of planet types and stellar characteristics can be investigated. For example; Are small planets found when Jupiter-mass planets are also present in inner orbits? What is the frequency of small planets compared to Jupiter-mass planets? What is the frequency and distribution of planets intermediate in size and mass to that of Earth and Jupiter? What correlations exist between planet size, distribution, and frequency with the characteristics of the stars they orbit? A comparison between model predictions and observation should be a useful step in evolving better models of planetary system formation and help put the formation of our Solar System in perspective.

Bourcki, W. J.

The Submillimeter Wave Astronomy Satellite: Science objectives and instrument description

The submillimeter wave astronomy satellite (SWAS) mission is dedicated to the investigation of star formation and interstellar chemistry. In order to perform the mission, SWAS will survey dense molecular clouds within the Milky Way Galaxy in either the ground state or a low-lying transition of five astrophysically-significant species: H2O, H2(18)O, O2, C I and (13)CO. The observation of these lines will: test theories that predict that these species are dominant coolants of molecular clouds during early stages of their collapse to form stars and planets, and supply information concerning the abundance of species central to the chemical models of dense interstellar gas. The SWAS will use two independent Schottky barrier diode mixers and a 53 x 68 sq cm, off-axis Cassegrain antenna.

Melnick, G. J.

The Kepler Mission: A Mission to Determine the Frequency of Inner Planets Neat the Habitable Zone of a Wide Range of Stars

The surprising discovery of giant planets in inner orbits around solar-like stars has brought into question our understanding of the development and evolution of planetary systems, including our solar system. To make further progress, it is critical to detect and obtain data on the frequency and characteristics of Earth-class planets. The Kepler Mission is designed to be a quick, low-cost approach to accomplish that objective. Transits by Earth-class planets produce a fractional change in stellar brightness of 5 x 10(exp -5) to 40 x 10(exp -5) lasting for 4 to 16 hours, From the period and depth of the transits, the orbit and size of the planets can be calculated. The proposed instrument is a one-meter aperture photometer with a 12 deg field-of-view (FOV). To obtain the required precision and to avoid interruptions caused by day-night and seasonal cycles, the photometer will be launched into a heliocentric orbit. It will continuously and simultaneously monitor the flux from 80,000 dwarf stars brighter than 14th magnitude in the Cygnus constellation. The mission tests the hypothesis that the formation of most stars produces Earth-class planets in inner orbits. Based on this assumption and the recent observations that 2% of the stars have giant planets in inner orbits, several types of results are expected from the mission: 1. From transits of Earth-class planets, about 480 planet detections and 60 cases where two or more planets are found in the same system. 2. From transits of giant planets, about 160 detections of inner-orbit planets and 24 detections of outer-orbit planets. 3. From the phase modulation of the reflected light from giant planets, about 1400 planet detections with periods less than a week, albedos for 160 of these giant planets, and densities for seven planets.

Borucki, W. J.

The Kepler Mission: A Mission to Determine the Frequency of Inner Planets Near the Habitable Zone of a Wide Range of Stars

The surprising discovery of giant planets in inner orbits around solar-like stars has brought into question our understanding of the development and evolution of planetary systems, including our solar system. To make further progress, it is critical to detect and obtain data on the frequency and characteristics of Earth-class planets. The Kepler Mission is designed to be a quick, low-cost approach to accomplish that objective. Transits by Earth-class planets produce a fractional change. in stellar brightness of 5 x 10(exp -5) to 40 x 10(exp -5) lasting for 4 to 16 hours. From the period and depth of the transits, the orbit and size of the planets can be calculated. The proposed instrument is a one-meter aperture photometer with a 12 deg. field-of-view (FOV). To obtain the required precision and to avoid interruptions caused by day-night and seasonal cycles, the photometer will be launched into a heliocentric orbit. It will continuously and simultaneously monitor the flux from 80,000 dwarf stars brighter than 14th magnitude in the Cygnus constellation. The mission tests the hypothesis that the formation of most stars produces Earth-class planets in inner orbits. Based on this assumption and the recent observations that 2% of the stars have giant planets in inner orbits, several types of results are expected from the mission: 1. From transits of Earth-class planets, about 480 planet detections and 60 cases where two or more planets are found in the same system. 2. From transits of giant planets, about 160 detections of inner-orbit planets and 24 detections of outer-orbit planets. 3. From the phase modulation of the reflected light from giant planets, about 1400 planet detections with periods less than a week, albedos for 160 of these giant planets, and densities for seven planets.

Borucki, W. J.

Excitation of the low lying vibrational levels of H2O by O(3P) as measured on Spacelab 2

The data from the infrared telescope (IRT), which was flown on space shuttle Challenger Spacelab 2 mission (July 1985), were originally reported by Koch et al. (1987) as originating from near orbital emissions, primarily H2O. In this study, analysis of this data was extended to determine the collisional cross sections for the excitation of the low lying vibrational levels of H2O, present in the orbiter cloud, by atmospheric O(3P). The evaluation of the contribution to the measured signal from solar excitation and ram O excitation of outgassing H2O permits the determination of the H2O column density and the excitation cross section of the (101) level at an O(3P) velocity of approximately 7.75 km/s. Contributions to the radiation in the 1.7-3.0 micron band by transitions from the (100), (001), and multiquantum excited levels are discussed. The findings of the study are (1) the IRT data for the 4.5-9.5 micron and the nighttime data for the 1.7-3.0 micron sensors are consistent with being explained by collision excitation of H2O by O(3P), (2) diurnal variations of 4.5-9.5 micron intensities follow the model predicted O density for a full orbit, (3) daytime increases in the H2O cloud density were not evident, (4) the cross sections for the collisional excitation process are derived and compared to values computated by Johnson (1986) and Redmon et al. (1986), (5) theoretical investigation suggests greater than 60% of the radiation from H2O is a result of multiphoton emission resulting from collisional multiquanta excitation, and (6) the large daytime increase in the 1.7-3.0 micron intensity data suggests that O(+) may likely be instrumental in producing excited H2O(+) through charge exchange.

Meyerott, R. E.

Particle sightings by the infrared telescope on Spacelab 2

Part of the objective of the cooled infrared telescope on Spacelab 2 was to determine the particle environment around the Space Shuttle. The telescope scanned the sky in six wavelength bands ranging from 2 to 100 microns with high time resolution. Dust particles could be identified from their particular signature in the data stream. Particle data from about 4 h early in the mission were analyzed in terms of size, color temperature, velocity, and time. The 1100 particles that were seen were slow moving and ranged in color temperature from 190 to 350 K with a few much hotter. The minimum detectable diameter is between 5 and 13 microns, depending on temperature. The size distribution resembles sample distributions collected at a Shuttle preparation facility. Although particle detection rates varied widely with time, no specific events were identified to be associated with particle production. It was not possible to determine the particle composition, although it was probably not ice.

Simpson, J. P.

The estimation of background production by cosmic rays in high-energy gamma ray telescopes

A calculational method of estimating instrumental background in high-energy gamma-ray telescopes, using the hadronic Monte Carlo code FLUKA87, is presented. The method is applied to the SAS-2 and EGRET telescope designs and is also used to explore the level of background to be expected for alternative configurations of the proposed GRITS telescope, which adapts the external fuel tank of a Space Shuttle as a gamma-ray telescope with a very large collecting area. The background produced in proton-beam tests of EGRET is much less than the predicted level. This discrepancy appears to be due to the FLUKA87 inability to transport evaporation nucleons. It is predicted that the background in EGRET will be no more than 4-10 percent of the extragalactic diffuse gamma radiation.

Edwards, H. L.

The submillimeter wave astronomy satellite

The Submillimeter Wave Astronomy Satellite (SWAS) selected for flight as part of the Small Explorer Program is described. SWAS consists of a 55 by 71 cm near optical quality off axis primary mirror, two heteorodyne radiometers with Schottky barrier diode mixers, and a single broadband (1.4 GHz) Acousto Optical Spectrometer (AOS). SWAS primary objective is to conduct a high spectral resolution survey of galactic molecular clouds in low lying transitions of water, molecular oxygen, atomic carbon and isotopic carbon monoxide. These species are crucial in gaining a better understanding of the chemistry and cooling of dense molecular clouds.

Melnick, Gary J.

Overview of measurements from the infrared telescope on Spacelab 2

A small helium cooled IR telescope flown on Spacelab-2 in July/August 1985 was used to make infrared measurements between 2 microns and 120 microns. New data were obtained on the structure of the Galaxy at 2 microns and 7 microns showing it to be much broader at these wavelengths than at longer wavelengths. The IR emission due to contamination from the Shuttle was found to be greater than anticipated, indicating the induced environment to be much higher than the planned limits. Aspects of superfluid helium management in zero-G and of a cryogenically cooled telescope design were also tested.

Koch, D. G.

Infrared observations of contaminants from Shuttle flight 51-F

A small helium-cooled infrared telescope, IRT, was flown on the Shuttle in July/August 1985. The principal astrophysical objectives were to measure the large scale structure of sources and the background radiation. A cold shutter was incorporated to permit absolute flux measurements. Additionally, the engineering objectives included setting upper limits on the infrared radiation from the local environment. Even though the local background overwhelmed the astrophysical background, astronomical sources were still detectable superimposed on this background radiation. Data are presented covering the spectral range from 2 microns to 120 microns. The spatial, spectral, and temporal variations are described. Based on the spectral character and variability in different wavelength bands, the background radiation does not appear to have a single origin. In this paper, the results on the Shuttle environment are presented.

Koch, D. G.

Wide field and diffraction limited array camera for SIRTF

The Infrared Array Camera for the space Infrared Telescope Facility (SIRTF/IRAC) is capable of two-dimensional photometry in either a wide field or diffraction-limited mode over the wavelength interval from 2 to 30 microns. Three different two-dimensional direct readout (DRO) array detectors will be used: Band 1-InSb or Si:In (2-5 microns) 128 x 128 pixels, Band 2-Si:Ga (5-18 microns) 64 x 64 pixels, and Band 3-Si:Sb (18-30 microns) 64 x 64 pixels. The hybrid DRO readout architecture has the advantages of low read noise, random pixel access with individual readout rates, and nondestructive readout. The scientific goals of IRAC are discussed, which are the basis for several important requirements and capabilities of the array camera: (1) diffraction-limited resolution from 2-30 microns, (2) use of the maximum unvignetted field of view of SIRTF, (3) simultaneous observations within the three infrared spectral bands, and (4) the capability for broad and narrow bandwidth spectral resolution. A strategy has been developed to minimize the total electronic and environmental noise sources to satisfy the scientific requirements.

Fazio, G. G.

Wide field and diffraction limited array camera for SIRTF

The Infrared Array Camera for the Space Infrared Telescope Facility (SIRTF/IRAC) is capable of two-dimensional photometry in either a wide field or diffraction-limited mode over the wavelength interval from 2 to 30 microns. Three different two-dimensional direct readout (DRO) array detectors are being considered: Band 1-InSb or Si:In (2-5 microns) 128 x 128 pixels, Band 2-Si:Ga (5-18 microns) 64 x 64 pixels, and Band 3-Si:Sb (18-30 microns) 64 x 64 pixels. The hybrid DRO readout architecture has the advantages of low read noise, random pixel access with individual readout rates, and nondestructive readout. The scientific goals of IRAC are discussed, which are the basis for several important requirements and capabilities of the array camera: (1) diffraction-limited resolution from 2-30 microns, (2) use of the maximum unvignetted field of view of SIRTF, (3) simultaneous observations within the three infrared spectral bands, and (4) the capability for broad and narrow bandwidth spectral resolution. A strategy has been developed to minimize the total electronic and environmental noise sources to satisfy the scientific requirements.

Fazio, G. G.

Infrared measurements of spacecraft glow planned for Spacelab 2

A liquid helium cooled infrared telescope (IRT) was to be flown in July 1985 on Spacelab 2. The instrument is designed to measure both diffuse and discrete infrared astronomical sources, including the zodiacal light, galactic, and extragalactic components, as well as to evaluate the induced Orbiter environment. The focal plane contains ten photoconductive detectors covering six broad bands from 2 to 120 microns. Each detector has a 0.5 by 1.0 deg field of view optimized for detection of extended sources of IR radiation. Except for the 2 micron detector, the system noise is limited by the sky background noise. The measurements planned for the IRT use the 1 meter base of the Plasma Diagnostic Package (PDP), an already existing SL 2 experiment, as the glow generating surface. The measurements are repeated changing the position of the PDP, the attitude of the Orbiter, and the ram direction in an effort to remove both the thermal component of the PDP emission and the cosmic background radiation.

Fazio, G. G.

A large-area gamma-ray imaging telescope system

The concept definition of using the External Tank (ET) of the Space Shuttle as the basis for constructing a large area gamma ray imaging telescope in space is detailed. The telescope will be used to locate and study cosmic sources of gamma rays of energy greater than 100 MeV. Both the telescope properties and the means whereby an ET is used for this purpose are described. A parallel is drawn between those systems that would be common to both a Space Station and this ET application. In addition, those systems necessary for support of the telescope can form the basis for using the ET as part of the Space Station. The major conclusions of this concept definition are that the ET is ideal for making into a gamma ray telescope, and that this telescope will provide a substantial increase in collecting area.

Koch, D. G.

The design of a multi-detector spectrometer for the infrared

A modified Ebert-Fastie spectrometer has been developed for atmospheric temperature sounding applications. The device is described with reference to its resolution, grating, focal-length mirror, mirror, equivalent f-number, and projected area of grating. The images of the entrance slit appear tilted backwards away from the concave mirror. Astigmatism and spherical aberration are reduced by asperizing the mirror. The resolution and f-number of the instrument are limited by the sagittal coma. The orientation and size of the exit slit are functions of wavelength.

Koch, D. G.