Cloud-Control of Legacy Building Automation System: A case study

As Internet of Things devices and cloud-based platforms become more mature, Energy Management and Information Systems (EMIS) are increasingly gaining momentum in the building industry. In large commercial buildings, Fault-Detection and Diagnostic (FDD) and energy information systems (EIS) are now established technologies with tens of providers and thousands of deployment sites across North America. The new frontier for the EMIS technology is now represented by control systems that use advanced system optimization (ASO) methods to improve the operations of the HVAC system. Given the complexity of the integration of such systems with the existing building automation systems (BAS) and the higher risk involved with direct control of the HVAC, these systems are still emerging in the market. This paper presents the results of a project in which a start-up company partnered with a research institution to develop a cloud-based software EMIS solution and deployed it in a university campus in California. The software system included advanced sensing, data acquisition, storage and advanced control and analytics applications developed on top of the native BAS. The new platform controls ten buildings on the campus and the FDD and the ASO applications deployed on this platform were able to generate energy savings of up to 35% and 25% in certain buildings for each functionality respectively. Where the platform did not save energy, it improved building service (air quality). Lessons learned include the importance of collaborating with and training the building operators and evaluating whether the legacy system can work reliably with the new technology.

Prakash, Anand Krishnan↗

Harvesting the low-hanging fruit of high energy savings -- Virtual Occupancy using Wi-Fi Data

Approximately 20% of primary energy consumed in the U.S. is attributed to HVAC use. Ideally, HVAC operation would be driven by actual building occupancy, but lack of reliable occupancy information often results in the use of conservative static schedules. This disparity is even more pronounced in a college campus, where the function of each space differs by building (classrooms, offices, libraries) and the class schedules change frequently -- every semester, day of week, and hour. While several research papers propose the use of counts of the Wi-Fi connections (e.g., phones, computers) as a proxy for occupancy, few real-world implementations exist. This paper describes the development and deployment of an open-source Wi-Fi-to-Occupancy software library in 65 buildings of a college campus, and the planned integration with the building energy management and control system at the building scale. Over a year of Wi-Fi data was gathered into distinct academic periods, including fall and spring semester, academic breaks, and summer sessions. Patterns such as students moving between classrooms, closing laptops before exams, etc., can be visualized from the data. Approximating occupancy from Wi-Fi data presents challenges which we address in this project -- for example, identifying static devices, or estimating the ratio of devices per person. Utilizing real-time occupancy data to inform optimal HVAC schedules and ventilation rates creates the potential to identify and reduce energy waste. Other potential applications include forecasting occupancy, and using Wi-Fi data to predict peak demands. Finally, the paper discusses how to easily scale these tools to other buildings.

Pritoni, Marco↗

Efficient and Zero Net Energy-Ready Plug Loads

Plug loads are the devices plugged into common electrical outlets. Modern buildings contain hundreds of these devices which, together, are responsible for at least 25 percent of the energy use in California buildings. Energy consumed by plug loads is increasing because the “Internet of Things” is, to a great extent, the “Internet of Plug Loads.” This project developed technologies that will reduce the energy use of plug loads. Two crosscutting strategies were investigated in detail: (1) technologies to reduce standby power use to near zero, and (2) methods to increase the use of direct current (DC) as a power source. Two new approaches to reduce standby to near zero were developed and have potential applicability to a wide range of devices. Prototype DC appliances were developed to demonstrate energy savings by bypassing power supplies and avoiding other losses. Networks of DC-powered devices can save even more energy and provide other benefits, such as resiliency during power outages. A unique category of energy-using devices was identified that provide life safety, health, and security to building occupants. Their installation or use is dictated by building codes, health providers, insurance companies, and other entities—none of whom would ordinarily prioritize energy efficiency. In the case of ground fault circuit interrupts (GFCIs), savings of 80 percent appear possible, simply by adopting the most efficient designs. Home medical equipment, particularly oxygen concentrators, are a rising category of energy use where significant savings are possible. This report also reviews the codes, standards, and other policies that affect energy use of plug loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Reporting: Device Demonstration, Communication Protocols, and Codes and Standards

Energy reporting is the principle that all energy-using devices in buildings should be able to track their own energy use and report this to the local network. Energy reporting can provide building owners with easy access to highly granular energy use data. This report makes the case that energy reporting should become a free basic feature of all devices, and reports on a project intended to move us towards that goal. The project collected a set of demonstration devices with energy reporting features, including products that were modified by the project team or the manufacturer, or are already available for sale. To show these devices operating live at meetings and conferences, the team created a management system that queries the energy reporting devices for their data, stores the data, and displays it in compelling visualizations. The devices covered a wide range, including heating, ventilation, and air conditioning (thermostat and air purifier); lighting (individual bulb, task light, and auto-dimming overhead light); a vehicle charger; a water heater; electronics (notebook personal computer and universal serial bus charger); and three external meters (one integral with a dimming light switch). The demonstration uses a variety of communication protocols. The report reviews existing communication protocols that support energy reporting and describes how to use them with a proposed reference data model for energy reporting. It also assesses ways that energy codes and standards processes can be leveraged to drive energy reporting technology into the market. Energy reporting could ultimately save California on the order of 2.5 terawatt-hours per year and about $0.8 billion per year. Energy reporting is a highly practical technology with minimal (sometimes no) cost to consumers and manufacturers. This report discusses creation of the energy reporting devices themselves, analysis and recommendations for data models and protocols for energy reporting, and energy codes and standards implications of energy reporting technology. While energy reporting does not directly save energy, it provides information for better decision-making to save energy in changing equipment operation, maintenance, and replacement.

devices↗

Direct Current as an Integrating Platform for ZNE Buildings with EVs and Storage: DC Direct Systems – A Bridge to a Low Carbon Future?

Cost effective zero net energy (ZNE) schemes exist for many types of residential and commercial buildings. Yet, today’s alternating current (AC) based ZNE designs may be as much as 10% to 20% less efficient, more costly, and more complicated than a design based on direct current (DC) technologies. An increasing number of research organizations and manufacturers are just starting the process of developing products and conducting research and development (R&D) efforts. These early R&D efforts indicate that the use of DC technologies may deliver many energy and non-energy benefits relative to AC-based typologies. DC ZNE schemes may provide for an ideal integrating platform for natively DC-based onsite generation, storage, electric vehicle (EV) charging and end-use loads. Emerging empirical data suggest that DC end-use appliances are more efficient, simpler, more durable, and lower cost. DC technologies appear to provide ratepayers a lower cost pathway to achieve resilient ZNE buildings, and simultaneously yield a plethora of benefits. This paper draws from the current research effort entitled "Direct Current as an Integrating and Enabling Platform," co-led by the Lawrence Berkeley National Laboratory (LBNL), the California Institute for Energy and the Environment (CIEE), the Electric Power Research Institute (EPRI) and funded under the California Energy Commission’s Energy Program Investment Charge (CEC EPIC). The first phase of this EPIC research is focused on assembling and summarizing known global performance information on DC and DC-AC hybrid end-use appliances and power systems. This paper summarizes the information and insights gained from this research effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Public Participation to Improve MELs Energy Data Collection

Miscellaneous and electronic loads (MELs) comprise an increasing share of building energy consumption. Large-scale data collection is needed to inform meaningful energy reduction strategies because of the diversity of MELs and our lack of understanding about how people use them. Traditional methods of data collection, however, usually incur high labor and metering equipment expenses. As an alternative, this paper investigates the feasibility of crowdsourcing data collection to satisfy at least part of the data collection needs with acceptable accuracy. We assessed the reliability and accuracy of crowd-sourced data by recruiting 18 volunteers and testing our crowdsourcing protocol. The protocol asked volunteers to perform measurement tasks for three MELs devices of increasing complexity 1) record power meter and MELs product characteristics, 2) identify and measure all power modes available, and 3) report the measured power. Volunteers performed reasonably well for devices with functionalities with which they were familiar, but many could not correctly identify all available power modes in complex devices. Accuracy may improve when participants measure the power used by familiar devices in their home, or by providing more specific instructions, e.g. videos. Furthermore, crowdsourcing data collection from individual homeowners has the potential to generate valuable information about MELs energy use in homes when integrated with existing programs such as Home Energy Saver and Building America.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Monitoring of Residential Hot Water Distribution Systems

Current water distribution systems are designed such that users need to run the water for some time to achieve the desired temperature, wasting energy and water in the process. We developed a wireless sensor network for large-scale, long time-series monitoring of residential water end use. Our system consists of flow meters connected to wireless motes transmitting data to a central manager mote, which in turn posts data to our server via the internet. This project also demonstrates a reliable and flexible data collection system that could be configured for various other forms of end use metering in buildings. The purpose of this study was to determine water and energy use and waste in hot water distribution systems in California residences. We installed meters at every end use point and the water heater in 20 homes and collected 1s flow and temperature data over an 8 month period. For a typical shower and dishwasher events, approximately half the energy is wasted. This relatively low efficiency highlights the importance of further examining the energy and water waste in hot water distribution systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Public Participation to Improve MELs Energy Data Collection

Miscellaneous Electric Loads (MELs) have proliferated in the last decade, and comprise an increasing share of building energy consumption. Because of the diversity of MELs and our lack of understanding about how people use them, large-scale data collection is needed to inform meaningful energy reduction strategies. Traditional methods of data collection, however, usually incur high labor and metering equipment expenses. As an alternative, this paper investigates the feasibility of crowdsourcing data collection to satisfy at least part of the data collection needs with acceptable accuracy. This study assessed the reliability and accuracy of crowdsourced data, by recruiting over 20 volunteers (from the 2012 Lawrence Berkeley Lab, Open House event) to test our crowdsourcing protocol. The protocol asked volunteers to perform the following tasks for three test products with increasing complexity - record power meter and product characteristics, identify all power settings available, and report the measured power. Based on our collected data and analysis, we concluded that volunteers performed reasonably well for devices with functionalities with which they are familiar, and might not produce highly accurate field measurements for complex devices. Accuracy will likely improve when participants are measuring the power used by devices in their home which they know how to operate, by providing more specific instructions including instructional videos. When integrated with existing programs such as the Home Energy Saver tool, crowdsourcing data collection from individual homeowners has the potential to generate a substantial amount of information about MELs energy use in homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation Models for Improved Water Heating Systems

This research improved the design of computer simulation models of water heaters and hot water distribution systems to increase their accuracy and flexibility, and to allow for future inclusion of new technologies. The models will be incorporated into the Buildings Library at Lawrence Berkeley National Laboratory to assist those performing whole-building energy simulations.