Engineering PapersSearch

Engineering topics

Kittel, Peter

Publications and source records attributed to Kittel, Peter.

30 records · Page 2

Performance of all-metal demountable cryogenic seals at superfluid helium temperatures

Two all-metal demountable cryogenic seals with an outside diameter of 36.6 mm, inside diameter of 27.2 mm, and thickness of 0.51 mm were leak-tested at room temperature (300 K), liquid nitrogen temperature (21 cycles at 77 K), liquid helium temperature (9 cycles at 4.2 K), and superfluid helium temperature (4 cycles at 1.6 K). Each seal was mounted and demounted for 13 cycles. Thickness measurements at 90 deg intervals along the circumference showed a maximum seal compression of 0.038 mm. Leak-rate measurements at all temperatures showed no detectable leak above the helium background level, typically 0.1 x 10(-9) std-cc/sec, during testing.

Salerno, Louis J.

Performance of all-metal demountable cryogenic seals at superfluid helium temperatures

Two all-metal demountable cryogenic seals with an outside diameter of 36.6 mm, inside diameter of 27.2 mm, and thickness of 0.51 mm were leak-tested at room temperature (300 K), liquid nitrogen temperature (21 cycles at 77 K), liquid helium temperature (9 cycles at 4.2 K), and susperfluid helium temperature (4 cycles at 1.6 K). Each seal was mounted and demounted for 13 cycles. Thickness measurements at 90 deg intervals along the circumference showed a maximum seal compression of 0.038 mm. Leak-rate measurements at all temperatures showed no detectable leak above the helium background level, typically 0.1 x 10(-9) std-cc/sec, during testing.

Salerno, Louis J.

Superfluid helium orbital resupply - The status of the SHOOT flight experiment and preliminary user requirements

The Superfluid Helium On-Orbit Transfer (SHOOT) flight experiment is designed to demonstrate the components and techniques necessary to resupply superfluid helium to satellites or Space Station based facilities. A top level description as well as the development status of the critical components to be used in SHOOT are discussed. Some of these components include the thermomechanical pump, the fluid acquisition system, the normal helium and superfluid helium phase separators, Venturi flow meter, cryogenic valves, burst disks, and astronaut-compatible EVA coupler and transfer line. The requirements for the control electronics and software are given. A preliminary description of the requirements that must be met by a satellite requiring superfluid helium servicing is given. In particular, minimum and optimum plumbing arrangements are shown, transfer line flow impedance and heat input impacts are assessed, instrumentation is described, and performance parameters are considered.

Dipirro, Michael J.

Cryogenics for LDR

Three cryogenic questions of importance to Large Deployable Reflector (LDR) are discussed: the primary cooling requirement, the secondary cooling requirement, and the instrument changeout requirement.

Kittel, Peter

Temperature rise in superfluid helium pumps

The temperature rise of a fountain effect pump (FEP) and of a centrifugal pump (CP) are compared. Calculations and estimates presented here show that under the operating conditions expected during the resupply of superfluid helium in space, a centrifugal pump will produce a smaller temperature rise than will a fountain effect pump. The temperature rise for the FEP is calculated assuming an ideal pump, while the temperature rise of the CP is estimated from the measured performance of a prototype pump. As a result of this smaller temperature rise and of the different operating characteristics of the two types of pumps, transfers will be more effective using a centrifugal pump.

Kittel, Peter

Operating characteristics of isocaloric fountain-effect pumps

The governing equations of thermomechanical (fountain-effect) pumps are usually given for pumps operating at a constant temperature difference. These are the thermomechanical and mechanocaloric effects in which the pressure head and mass flow are independent of each other. Here, these equations are recast for a pump operating at a constant heat input (isocaloric). This form more closely represents how such pumps are likely to be used. Under these conditions, the pressure head and mass flow are shown to be related. For ideal pumps, the head and flow are related by a universal curve. For real pumps (those that have normal fluid leakage), a family of curves is developed. These curves approach the curve for an ideal pump at high flow rates. The isocaloric equations are also extended to multistage pumps.

Kittel, Peter

The superfluid helium on-orbit transfer (SHOOT) flight experiment

The SHOOT flight demonstration is being undertaken to verify component and system level technology necessary to resupply large superfluid helium dewars in space. The baseline configuration uses two identical 210 liter dewars connected by a transfer line which contains a quick disconnect coupling. The helium will be transferred back and forth between the dewars under various conditions of flow rate, parasitic heat load, and temperature. An astronaut Extra-vehicular Activity (EVA) is also planned to manually demate and mate the coupling. A number of components necessary for the flight are being developed. These components are described here.

Dipirro, Michael J.

Measuring Contact Thermal Conductances at Low Temperatures

Instrument measures thermal conductance of pressed contacts in liquid helium. Makes measurements automatically as function of force on pairs of brass samples having various surface finishes. Developed as part of effort to determine heat-transfer characteristics of bolted joints on cryogenically cooled focal planes in infrared equipment. Cylindrical chamber hangs from cover plate in bath of liquid helium. Inside chamber rocker arm applies controlled force to samples. Upper sample made slightly wider than lower one so two samples remain in complete contact even under slight lateral misalignment.

Salerno, Louis J.

Ames Research Center cryogenics program

Viewgraphs describe the Ames Research Center's cryogenics program. Diagrams are given of a fluid management system, a centrifugal pump, a flow meter, a liquid helium test facility, an extra-vehicular activity coupler concept, a dewar support with passive orbital disconnect, a pulse tube refrigerator, a dilution refrigerator, and an adiabatic demagnetization cooler.

Kittel, Peter

Helium technology issues

A number of future space missions require liquid helium for cooling scientific payloads. These missions will require the long term storage and resupply of liquid helium at temperatures of 1.4 - 2.1 Kelvin. In addition, some of the proposed instruments will require refrigeration to temperatures as low as 50 mK. A variety of liquid helium based refrigerator systems could provide this subkelvin cooling. The status of helium storage and refrigeration technologies and of several alternative technologies is presented here along with areas where further research and development are needed. (Helium resupply technologies are the topic of another presentation at this symposium). The technologies covered include passive and dynamic liquid helium storage, alternatives to liquid helium storage, He -3 refrigerators, He -3/He -4 dilution refrigerators, and alternative sub-kelvin coolers.

Kittel, Peter

Transferring superfluid helium in space

A simple thermodynamic model of a transfer system for resupplying liquid helium in space is presented, with application to NASA projects including the Space Infrared Telescope Facility, the Large Deployable Reflector, and the Hubble Space Telescope. The relations between different thermodynamic regimes that can be expected in the transfer line are used to study the relative efficiencies of various possible transfer techniques. Low heat leak into the transfer line, particularly at point sources such as the coupling, is necesssary for efficient transfer of liquid helium, and proper selection of supply tank temperature is important during helium resupply.

Kittel, Peter

System structural test results - Six PODS III supports

Passive orbital disconnect struts can potentially reduce the support conductance a factor of 10 over state-of-the-art tension band nondisconnect supports and cut helium dewar weights in half for the same lifetime. A series of thermal and structural tests were performed to verify that this performance improvement is real. Structural tests on a PODS-III support system (consisting of six struts) is reported here. The results show the predicted performance improvements can be achieved and the PODS-III supports are ready for flight applications. For large tankage systems requiring higher side load capability, a PODS-IV version is currently being developed.

Parmley, Richard T.