He-3 cooling systems for space

The development of a space-compatible He(3) refrigerator would provide a significant improvement in several areas of research in the 0.3 to 1 K temperature range. There are several methods of achieving these temperatures on Earth: He(3) refrigeration, dilution refrigeration, and adiabatic demagnetization refrigeration. The progress of adapting He(3) refrigeration for use in space is described. Various cycles and possible embodiments of He(3) refrigerators are described. Also included is an analysis of the liquid confinement and liquid-vapor phase-separation system. A possible configuration is then analyzed. Finally, the results of ground-based experiments will be discussed.

Kittel, P.

Bolometers operated at 0.1 K and 0.2 K cooled by adiabatic demagnetization

The construction of bolometers operating at temperatures of 0.1 K and 0.2 K and cooled by adiabatic demagnetization is reported. The electrical noise-equivalent power (NEP) of the bolometers was found to be 1.8 and 6.6 x 10 to the -16th W/sq rt Hz, respectively. These values are within a factor of two of the expected performance based upon bolometer theory. The thermistor material used was gallium-doped single-crystal germanium, for which a resistivity temperature dependence is found.

Lesyna, L.

Passive Module for Cryogenic Refrigeration

Refrigeration module with no moving parts attaches to cold plate of cryostat to reduce temperature. Module includes evaporation chamber, condenser and absorption pump.

Brooks, W.

Passive storage technologies

Advances in storage technology and how passive techniques could be applied to the storage of propellants at the space station are described. The devices considered are passive orbital disconnect struts, cooled shield optimization, liftweight shields and catalytic converters.

Kittel, P.

Temperature stability limits for an isothermal demagnetization refrigerator

It is pointed out that magnetic refrigeration can provide additional cooling for infrared detectors on space missions, taking into account the Shuttle Infrared Telescope Facility (SIRTF) and the Large Deployable Reflector (LDR). From a temperature of 2 K provided by the primary cryogens, magnetic refrigerators could cool bolometers or pumped photoconductors to 0.1 K or below. Such a reduction in operating temperature would increase the sensitivity for bolometers, while the response at longer wavelengths for pumped photoconductors would be improved. Two types of magnetic refrigeration cycles have been proposed. One type uses a complete demagnetization. The present investigation is concerned with the second type, which uses a feedback-controlled isothermal demagnetization, taking into account the temperature stability limits. Attention is given to control system resolution, thermometer noise, reaction time, and thermal time constants.

Kittel, P.

Long term cryogen storage in space - A feasibility study

The conduction of future space missions will require the long term storage of cryogens in space. Such missions will be performed in connection with the employment of the long life version of the Shuttle Infrared Telescope Facility (SIRTF), the Large Deployable Reflector (LDR), Gravity Probe B (GPB), Orbital Transfer Vehicles (OTVs), and the Space Station. The feasibility of building a long lifetime helium Dewar for space applications has been studied. A feasible concept was to be developed for a Shuttle-launchable 3-yr lifetime Dewar. The developed concept was to be used for the identification of key technology development areas. The desired long lifetime requires the minimization of the parasitic heat loads. It has been found that the majority of the parasitic heat load can be provided by the fiberglass-epoxy tension band supports. A new type of support system, the Passive Orbital Disconnect Strut (PODS), was developed to reduce the considered contribution to the heat load.

Kittel, P.

Passive orbital disconnect strut

The design and test results with a third generation passive orbital disconnect strut (PODS) for space-based cryogenic He dewars are presented. Three pairs of PODS struts support a tank and change lengths in response to gas and temperature changes. A thin wall fiberglass tube is used on the cold disconnect end, which can be operated on the ground or in space. Tests were performed to characterize heat flows across the cold end to a liquid He sink and subsequent vacuum pressure within the He tank. Heat transfer was lower than predicted, suggesting that longer dewar in-orbit lifetimes can be expected with the new PODS.

Parmley, R. T.

A helium-3 refrigerator employing capillary confinement of liquid cryogen

A condensation refrigerator suitable for operation in a zero gravity space environment was constructed. The condensed liquid refrigerant is confined by surface tension inside a porous metal matrix. Helium-4 and helium-3 gases were condensed and held in a copper matrix. Evaporative cooling of confined liquid helium-4 resulted in a temperature of 1.4K. Using a zeolite adsorption pump external to the cryostat, a temperature of 0.6 K was achieved through evaporative cooling of liquid helium-3. The amount of time required for complete evaporation of a controlled mass of liquid helium-4 contained in the copper matrix was measured as a function of the applied background power. For heating powers below 18 mW the measured times are consistent with the normal boiling of the confined volume of liquid refrigerant. At background powers above 18 mW the rapid rise in the temperature of the copper matrix the signature of the absence of confined liquid occurs in a time a factor of two shorter than that expected on the basis of an extrapolation of the low power data.

Ennis, D. J.

Thermal conductance measurements of pressed OFHC copper contacts at liquid helium temperatures

The thermal conductance of oxygen-free high conductivity (OFHC) copper sample pairs with surface finishes ranging from 0.1 to 1.6-micrometers rms roughness was investigated over the range of 1.6 to 6.0-K under applied contact forces up to 670 N. The thermal conductance increases with increasing contact force; however, no correlation can be drawn with respect to surface finish.

Salerno, L. J.

Ultimate temperature stability of a magnetic refrigerator

In recent years there has been an interest in using adiabatic demagnetization refrigeration in space to cool bolometers to the 0.1-0.3 K temperature range. Two different demagnetization schemes have been proposed for such refrigerators. Both methods start the same way: an isothermal magnetization followed by an adiabatic demagnetization. Once the operating temperature is reached, the two methods differ. The first method uses feedback control to perform an isothermal demagnetization. As reported, this system is limited by the resolution of the analog-to-digital converter used. While the stability of this system is the best reported to date (0.5 mK at 200 mK for 14 h), it is several orders of magnitude worse than the theoretical limit. The second method uses a complete demagnetization and allows the temperature to drift up uncontrolled. This system has the disadvantage that the responsivity and noise of a bolometer will also drift, and so will require continuous recalibration. There is some concern that fluctuations in the temperature control system of the first method would adversely affect the bolometer performance by increasing the system noise. The purpose of this note is to present the ultimate stability limit of an isothermal demagnetization feedback control system.

Kittel, P.

The 0.1K bolometers cooled by adiabatic demagnetization

The most straightforward way of reducing the noise equivalent power of bolometers is to lower their operating temperature. We have been exploring the possibility of using conventionally constructed bolometers at ultra-low temperatures to achieve NEP's suitable to the background environment of cooled space telescopes. We have chosen the technique of adiabatic demagnetization of a paramagnetic salt as a gravity independent, compact, and low power way to achieve temperatures below pumped He-3 (0.3 K). The demagnetization cryostat we used was capable of reaching temperatures below 0.08 K using Chromium Potassium Alum as a salt from a starting temperature of 1.5 K and a starting magnetic field of 30,000 gauss. Computer control of the magnetic field decay allowed a temperature of 0.2 K to be maintained to within 0.5 mK over a time period exceeding 14 hours. The refrigerator duty cycle was over 90 percent at this temperature. The success of these tests has motivated us to construct a more compact portable adiabatic demagnetization cryostat capable of bolometer optical tests and use at the 5m Hale telescope at 1mm wavelengths.

Roellig, T.

Thermal conductance of pressed contacts at liquid helium temperatures

It is pointed out that the optimum design of cryogenic instruments requires accurate thermal models. The present models are limited by a lack of knowledge of the low temperature thermal conductance of the bolted joints which are typically used in the instrument-to-system interface. In connection with studies of pressed contacts, it has been found that the thermal conductance does not obey the Wiedemann-Franz law. The present investigation is concerned with the characterization of the thermal conductance of pressed contacts at liquid helium-4 temperatures, taking into account the dependence of thermal contact conductance on applied force and temperature. It is shown that for the 0.4 micron OFHC copper pressed contact pair, the thermal conductance varies roughly as the second power of the temperature, and increases with increasing applied force.

Salerno, L. J.

Thermal conductance of pressed contacts at liquid helium temperatures

The thermal contact conductance of a 0.4 micrometer surface finish OFHC copper sample pair has been investigated from 1.6 to 3.8 K for a range of applied contact forces up to 670 N. Experimental data have been fitted to the relation Q = the integral alpha T to the nth power dt by assuming that the thermal contact conductance is a simple power function of the sample temperature. It has been found that the conductance is proportional to T squared and that conductance increases with an increase in applied contact force. These results confirm earlier work.

Salerno, L. J.

Single shot demountable self-contained He-3 refrigerator

The present investigation is concerned with the development of a self-contained demountable He-3 refrigerator which greatly increases the versatility of a cold-plate-style helium Dewar. The refrigerator is controlled by a single heater. The considered design makes it possible to achieve a temperature of 0.27 K without costly or time-consuming modifications to the Dewar. An example for an employment of a temperature of less than 1 K in space is related to the study of the critical behavior of He-3/He-4 mixtures in the absence of gravitational mixing. This requires a temperature of 0.87 K. Such low temperatures can also be utilized in the space operation of infrared telescopes. Attention is given to details of system design, the operating principles, and aspects of performance.

Kittel, P.

Sub-Kelvin temperatures in space

It is pointed out that the use of temperatures below 1 K in space would provide a significant improvement in several areas of research. The sensitivity of bolometers, for instance, can be improvead by as much as a factor of 50, if the operating temperature is lowered from 1.5 K to 0.3 K. A decrease in temperature to 0.1 K can provide even an improvement up to three orders of magnitude. Detectors based on the utilization of such improvements could be employed for far-infrared (100-1000 microns) photometry and spectroscopy in the low-background conditions of space. The study of critical phenomena in He-3/He-4 mixtures is also of interest, taking into account investigations at the tricritical point (0.87 K), which represents the junction of a first-order and a second-order transition. Tests in space are needed because gravity-related effects make adequate tests on earth impossible. He-3 refrigeration can be used to attain temperatures below 1 K. Adiabatic demagnetization can produuce temperatures below 0.3 K.

Kittel, P.

Magnetic refrigeration in space - Practical considerations

Various schemes of using adiabatic demagnetization to provide refrigeration in the 10-1000 mK range are discussed with particular reference to the requirements for use in space. The methods considered are complete demagnetization, isothermal demagnetization, moving magnet demagnetization, and continuous refrigeration. The requirements that are important for use in space are low mass, low power dissipation, high mechanical rigidity, modular design, and ease of use.

Kittel, P.

Steady-state vortex-line density in turbulent He II counterflow

We have measured the steady-state vortex-line density in turbulent counterflow using a second-sound-burst technique as a local probe. Contrary to the Vinen theory and previous assumptions, we find substantial line-density inhomogeneity and strong departures from the predicted heat-current dependence. Anomalous behavior of the line density at higher heat currents provides evidence for a new secondary flow state.

Ostermeier, R. M.

Portable He-3 detector cryostat for the far infrared

The design of a portable He-3 cryostat for far infrared detection applications is described, with a cutaway drawing of the cryostat, including bolometer and cooled optics, provided. Consideration is given to the selection and testing of various bolometer materials, including Ge:Ga and Ge:InSb; the resistance-temperature coefficients of the materials examined are presented. The absolute flux calibration of the detector system using a new temperature-modulated cold source method is described.

Radostitz, J. V.