Improved efficiency and precise temperature control of low-frequency induction-heating pure iron vapor source on ECR ion source

Multiply charged ions to be used prospectively are produced from solid pure material in an electron cyclotron resonance ion source (ECRIS). Recently a pure iron source is also required for the production of caged iron ions in the fullerene in order to control cells in vivo in bio-nano science and technology. We adopt directly heating iron rod by induction heating (IH) because it has non-contact with insulated materials which are impurity gas sources. We choose molybdenum wire for the IH coils because it doesn't need water cooling. To improve power efficiency and temperature control, we propose to the new circuit without previously using the serial and parallel dummy coils (SPD) for matching and safety. We made the circuit consisted of inductively coupled coils which are thin-flat and helix shape, and which insulates the IH power source from the evaporator. This coupling coils circuit, i.e. insulated induction heating coil transformer (IHCT), can be move mechanically. The secondary current can be adjusted precisely and continuously. Heating efficiency by using the IHCT is much higher than those of previous experiments by using the SPD, because leakage flux is decreased and matching is improved simultaneously. We are able to adjust the temperature in heating the vapor source around melting point. And then the vapor pressure can be controlled precisely by using the IHCT. We can control {+-}10K around 1500 Degree-Sign C by this method, and also recognize to controlling iron vapor flux experimentally in the extreme low pressures. Now we come into next stage of developing induction heating vapor source for materials with furthermore high temperature melting points above 2000K with the IHCT, and then apply it in our ECRIS.

74 ATOMIC AND MOLECULAR PHYSICS↗

Improvement of efficiency and temperature control of induction heating vapor source on electron cyclotron resonance ion source

An electron cyclotron resonance ion source (ECRIS) is used to generate multicharged ions for many kinds of the fields. We have developed an evaporator by using induction heating method that can generate pure vapor from solid state materials in ECRIS. We develop the new matching and protecting circuit by which we can precisely control the temperature of the induction heating evaporator. We can control the temperature within {+-}15 deg. C around 1400 deg. C under the operation pressure about 10{sup -4} Pa. We are able to use this evaporator for experiment of synthesizing process to need pure vapor under enough low pressure, e.g., experiment of generation of endohedral Fe-fullerene at the ECRIS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study on the beam transport from the Bio-Nano ECRIS

The beam transport of N{sup +} ion and C{sub 60}{sup +} ion in the Bio-Nano ECRIS with min-B configuration was investigated based on the ion beam profiles. The N{sup +} beam could be focused under the low-beam current conditions. Also the C{sub 60}{sup +} beam could be focused in spite of the large space-charge effect which will lead the divergence of the beam. We confirmed that our beam transport system works well even for the C{sub 60}{sup +} ion beam. We estimated the highest C{sub 60}{sup +} beam current with the focused beam profile by comparing the N{sup +} ion beam.

43 PARTICLE ACCELERATORS↗

Status of ion sources at National Institute of Radiological Sciences

The National Institute of Radiological Sciences (NIRS) maintains various ion accelerators in order to study the effects of radiation of the human body and medical uses of radiation. Two electrostatic tandem accelerators and three cyclotrons delivered by commercial companies have offered various life science tools; these include proton-induced x-ray emission analysis (PIXE), micro beam irradiation, neutron exposure, and radioisotope tracers and probes. A duoplasmatron, a multicusp ion source, a penning ion source (PIG), and an electron cyclotron resonance ion source (ECRIS) are in operation for these purposes. The Heavy-Ion Medical Accelerator in Chiba (HIMAC) is an accelerator complex for heavy-ion radiotherapy, fully developed by NIRS. HIMAC is utilized not only for daily treatment with the carbon beam but also for fundamental experiments. Several ECRISs and a PIG at HIMAC satisfy various research and clinical requirements.

07 ISOTOPE AND RADIATION SOURCES↗

A review of ion sources for medical accelerators (invited)

There are two major medical applications of ion accelerators. One is a production of short-lived isotopes for radionuclide imaging with positron emission tomography and single photon emission computer tomography. Generally, a combination of a source for negative ions (usually H- and/or D-) and a cyclotron is used; this system is well established and distributed over the world. Other important medical application is charged-particle radiotherapy, where the accelerated ion beam itself is being used for patient treatment. Two distinctly different methods are being applied: either with protons or with heavy-ions (mostly carbon ions). Proton radiotherapy for deep-seated tumors has become widespread since the 1990s. The energy and intensity are typically over 200 MeV and several 10{sup 10} pps, respectively. Cyclotrons as well as synchrotrons are utilized. The ion source for the cyclotron is generally similar to the type for production of radioisotopes. For a synchrotron, one applies a positive ion source in combination with an injector linac. Carbon ion radiotherapy awakens a worldwide interest. About 6000 cancer patients have already been treated with carbon beams from the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan. These clinical results have clearly verified the advantages of carbon ions. Heidelberg Ion Therapy Center and Gunma University Heavy Ion Medical Center have been successfully launched. Several new facilities are under commissioning or construction. The beam energy is adjusted to the depth of tumors. It is usually between 140 and 430 MeV/u. Although the beam intensity depends on the irradiation method, it is typically several 10{sup 8} or 10{sup 9} pps. Synchrotrons are only utilized for carbon ion radiotherapy. An ECR ion source supplies multi-charged carbon ions for this requirement. Some other medical applications with ion beams attract developer's interests. For example, the several types of accelerators are under development for the boron neutron capture therapy. This treatment is conventionally demonstrated by a nuclear reactor, but it is strongly expected to replace the reactor by the accelerator. We report status of ion source for medical application and such scope for further developments.

43 PARTICLE ACCELERATORS↗

Low energy Fe{sup +} beam irradiation to C{sub 60} thin film

We have developed an electron cyclotron resonance ion source apparatus, which is designed for the production of endohedral fullerene. In this study, we irradiated the Fe{sup +} beam to the C{sub 60} thin film. We changed the experimental condition of the dose and the ion energy. We could observe the Fe + C{sub 60} peak by analysis of the time-of-flight mass spectrometry. The highest intensity of the Fe + C{sub 60} peak was observed at the ion energy of 200 eV. The Fe + C{sub 60} peak intensity tended to become high in the case of long irradiation time and large dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy-dependent charge-changing cross sections and proton distribution of {sup 28}Si

The charge-changing cross sections (sigma{sub cc}) of {sup 28}Si on a carbon target were measured with high precision at intermediate energies from 100 to 600 MeV/nucleon. The measured sigma{sub cc} decreases rapidly from low energies up to 200 MeV/nucleon, whereas at higher energies it appears almost constant. The energy dependence of sigma{sub cc} is compared with a Glauber-type model calculation where only the proton distribution of {sup 28}Si is taken into account. A phenomenological correction factor deduced from the present data satisfactorily reproduces the experimental sigma{sub cc} for other stable nuclei, whose charge distributions were determined by electron scattering and muon capture experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bio-Nano ECRIS: An electron cyclotron resonance ion source for new materials production

We developed an electron cyclotron resonance ion source (ECRIS) for new materials production on nanoscale. Our main target is the endohedral fullerenes, which have potential in medical care, biotechnology, and nanotechnology. In particular, iron-encapsulated fullerene can be applied as a contrast material for magnetic resonance imaging or microwave heat therapy. Thus, our new ECRIS is named the Bio-Nano ECRIS. In this article, the recent progress of the development of the Bio-Nano ECRIS is reported: (i) iron ion beam production using induction heating oven and (ii) optimization of singly charged C{sub 60} ion beam production.

36 MATERIALS SCIENCE↗

Isotopic anomaly for carbon ions in an electron cyclotron resonance ion source

In many experiments methods were applied to increase the highly charged ion output from an electron cyclotron resonance ion source; the gas-mixing method is still generally being applied. The dominant role of the masses of the ions in the gas-mixture was apparent. Two basically differing mechanisms could to first order explain most of the observations. A significant mass effect showed up in a mixture of oxygen isotopes, the so-called oxygen anomaly; so far that effect could be explained in zeroth order only. The anomaly was observed later for nitrogen isotopes as well. In the present experiment it is shown that the anomaly also exists for carbon isotopes, where the necessity of feeding the source with carbon-hydrogen compounds brings about an essential different experimental fact.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MIVOC method with temperature control

The Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences has been used for cancer therapy, physics, and biology experiments since 1994. Its ion sources produce carbon ion for cancer therapy. They also produce various ions (H{sup +}-Xe{sup 21+}) for physics and biology experiments. Most ion species are produced from gases by an 18 GHz electron cyclotron resonance ion source. However, some of ion species is difficult to produce from stable and secure gases. Such ion species are produced by the sputtering method. However, it is necessary to reduce material consumption rate as much as possible in the case of rare and expensive stable isotopes. We have selected ''metal ions from volatile compounds method'' as a means to solve this problem. We tested a variety of compounds. Since each compound has a suitable temperature to obtain the optimum vapor pressure, we have developed an accurate temperature control system. We have produced ions such as {sup 58}Fe{sup 9+}, Co{sup 9+}, Mg{sup 5+}, Ti{sup 10+}, Si{sup 5+}, and Ge{sup 12+} with the temperature control.

43 PARTICLE ACCELERATORS↗

Review on heavy ion radiotherapy facilities and related ion sources (invited)

Heavy ion radiotherapy awakens worldwide interest recently. The clinical results obtained by the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan have clearly demonstrated the advantages of carbon ion radiotherapy. Presently, there are four facilities for heavy ion radiotherapy in operation, and several new facilities are under construction or being planned. The most common requests for ion sources are a long lifetime and good stability and reproducibility. Sufficient intensity has been achieved by electron cyclotron resonance ion sources at the present facilities.

43 PARTICLE ACCELERATORS↗

The compact electron cyclotron resonance ion source KeiGM for the carbon ion therapy facility at Gunma University

A high-energy carbon-ion radiotherapy facility is under construction at Gunma University Heavy Ion Medical Centre (GHMC). Its design was based on a study of the heavy ion radiotherapy at the National Institute of Radiological Sciences (NIRS) in order to reduce the size and construction cost of the facility. A compact electron cyclotron resonance ion source (ECRIS) for Gunma University, called KeiGM, was installed in 2008. It is almost a copy of the prototype ECRIS Kei2 which was developed by NIRS; meanwhile this prototype produced over 1 e mA of C{sup 4+} using C{sub 2}H{sub 2} gas (660 W and 40 kV). The beam intensity of C{sup 4+} was 600 e {mu}A with CH{sub 4} gas (250 W and 30 kV). The beam intensity satisfies the required value of 300 e {mu}A.