Engineering Papers⌕ Search

Engineering topics

King, P.

Publications and source records attributed to King, P..

Quasielastic $\overrightarrow{^{3}He}$ $(\overrightarrow{e},e′)$ asymmetry in the threshold region with a longitudinally polarized target

We report on the measurements of the double-spin asymmetry from electron- 3 He scattering in the threshold region of two- and three-body breakup of 3 He for 4-momentum transfer values of 0.1 and 0.2 (GeV/c) 2 . The measurement was done at Jefferson Lab using a polarized 3 He target with its spin aligned parallel to the beam direction. This asymmetry is sensitive to a combination of spin-dependent response functions not previously measured and may highlight differences in two body forces, meson-exchange currents and final-state interactions. The results of this measurement serve as a test of our understanding of few-body systems. When compared with calculations from plane wave impulse approximation and Faddeev calculations, we found that the latter, which use modern nuclear potentials and prescriptions for meson-exchange currents, demonstrate an overall good agreement with data.

Few-body nuclei↗

The SparkPix-S ASIC for the sparsified readout of 1 MHz frame-rate X-ray cameras at LCLS-II: pixel design and simulation results

Exploiting the “sparse” nature of the information in XPCS (X-ray Photon Correlation Spectroscopy) and XSVS (Speckle Visibility Spectroscopy) experiments, we present the SparkPix-S, a 3-sides buttable Application Specific Integrated Circuit (ASIC) based on a sparsified readout strategy for large-format hybrid detectors. The SparkPix-S architecture, based on the successful ePix family, will be composed as follows: a front-end 2-D matrix of 384×352 square pixels with 50 µm pitch is arranged to match the dimensions of a PIN Si-sensor matrix; charge readout, signal shaping and amplitude discrimination is performed at pixel-level, by means of a low-power (<18 µW) analog processor, which, in case of an event, negotiates access to an analog bus placed every other column; on the chip periphery (balcony), the information on each bus is digitized by an array of successive approximation analog-to-digital converters (SAR-ADCs) running at 10 Msps; on the digital back-end the global logic will generate the output data stream using low-voltage differential signalling (LVDS). A first prototype of the SparkPix-S, with a reduced matrix size of 96×96 pixels, is currently under production on a 130 nm CMOS technology. Simulated performance results show an equivalent noise charge <60 el. r.m.s. at 1 MHz repetition rate, with a maximum input energy of 60 keV and capability to discriminate charge signals with equivalent energy as low as 900 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining the gluonic gravitational form factors of the proton

The proton is one of the main building blocks of all visible matter in the Universe. Among its intrinsic properties are its electric charge, mass and spin. These properties emerge from the complex dynamics of its fundamental constituents—quarks and gluons—described by the theory of quantum chromodynamics. The electric charge and spin of protons, which are shared among the quarks, have been investigated previously using electron scattering. An example is the highly precise measurement of the electric charge radius of the proton. By contrast, little is known about the inner mass density of the proton, which is dominated by the energy carried by gluons. Gluons are hard to access using electron scattering because they do not carry an electromagnetic charge. Here we investigated the gravitational density of gluons using a small colour dipole, through the threshold photoproduction of the J/ψ particle. We determined the gluonic gravitational form factors of the proton from our measurement. Here we used a variety of models and determined, in all cases, a mass radius that is notably smaller than the electric charge radius. In some, but not all cases, depending on the model, the determined radius agrees well with first-principle predictions from lattice quantum chromodynamics. This work paves the way for a deeper understanding of the salient role of gluons in providing gravitational mass to visible matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

KATRIN: status and prospects for the neutrino mass and beyond

Abstract The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T 2 β decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a sub-eV sensitivity. After 1000 days of data-taking, KATRIN’s design sensitivity is 0.2 eV at the 90% confidence level. In this white paper we describe the current status of KATRIN; explore prospects for measuring the neutrino mass and other physics observables, including sterile neutrinos and other beyond-Standard-Model hypotheses; and discuss research-and-development projects that may further improve the KATRIN sensitivity.

beyond standard model↗

Electron acceleration at oblique angles via stimulated Raman scattering at laser irradiance >10 16 W cm –2 μm 2

The generation of hot, directional electrons via laser-driven stimulated Raman scattering (SRS) is a topic of great importance in inertial confinement fusion (ICF) schemes. Little recent research has been dedicated to this process at high laser intensity, in which back, side, and forward scatter simultaneously occur in high energy density plasmas, of relevance to, for example, shock ignition ICF. In this paper, we present an experimental and particle-in-cell (PIC) investigation of hot electron production from SRS in the forward and near-forward directions from a single speckle laser of wavelength λ 0 = 1.053μm, peak laser intensities in the range I 0 = 0.2–1.0×10 17 Wcm –2 and target electron densities between ne = 0.3–1.6% n c , where n c is the plasma critical density. As the intensity and density are increased, the hot electron spectrum changes from a sharp cutoff to an extended spectrum with a slope temperature T = 34 ± 1 keV and maximum measured energy of 350 keV experimentally. Multidimensional PIC simulations indicate that the high energy electrons are primarily generated from SRS-driven electron plasma wave phase fronts with k vectors angled ~50° with respect to the laser axis. These results are consistent with analytical arguments that the spatial gain is maximized at an angle which balances the tendency for the growth rate to be larger for larger scattered light wave angles until the kinetic damping of the plasma wave becomes important. The efficiency of generated high energy electrons drops significantly with a reduction in either laser intensity or target electron density, which is a result of the rapid drop in growth rate of Raman scattering at angles in the forward direction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing the Deuteron at Very Large Internal Momenta

We measure H-2(e, e' p)n cross sections at 4-momentum transfers of Q(2) = 4.5 +/- 0.5 (GeV/c)(2) over a range of neutron recoil momenta p(r), reaching up to similar to 1.0 GeV/c. We obtain data at fixed neutron recoil angles theta(nq) = 35 degrees, 45 degrees, and 75 degrees with respect to the 3-momentum transfer (q)over-right-arrow. The new data agree well with previous data, which reached p(r) similar to 500 MeV/c. At theta(nq) = 35 degrees and 45 degrees, final state interactions, meson exchange currents, and isobar currents are suppressed and the plane wave impulse approximation provides the dominant cross section contribution. We compare the new data to recent theoretical calculations, where we observe a significant discrepancy for recoil momenta P-r > 700 MeV/c.

Yero, C.↗

Characterization of silicon drift detectors with electrons for the TRISTAN project

Sterile neutrinos are a minimal extension of the standard model of particle physics. A promising model-independent way to search for sterile neutrinos is via high-precision β-spectroscopy. The Karlsruhe tritium neutrino (KATRIN) experiment, equipped with a novel multi-pixel silicon drift detector focal plane array and read-out system, named the TRISTAN detector, has the potential to supersede the sensitivity of previous laboratory-based searches. In this work we present the characterization of the first silicon drift detector prototypes with electrons and we investigate the impact of uncertainties of the detector’s response to electrons on the final sterile neutrino sensitivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Probing Few-Body Nuclear Dynamics via H 3 and He 3 ( e , e ' p ) pn Cross-Section Measurements

Here, we report the first measurement of the (e, e' p) three-body breakup reaction cross sections in helium-3 ( 3 He) and tritium ( 3 H) at large momentum transfer ($\langle{Q^2}\rangle$ ≈ 1.9 (GeV/c) 2 ) and x B > 1 kinematics, where the cross section should be sensitive to quasielastic (QE) scattering from single nucleons. The data cover missing momenta 40 ≤ p miss ≤ 500 MeV/c that, in the QE limit with no rescattering, equals the initial momentum of the probed nucleon. The measured cross sections are compared with state-of-the-art ab-initio calculations. Overall good agreement, within ±20%, is observed between data and calculations for the full p miss range for 3 H and for 100 ≤ p miss ≤ 350 MeV/c for 3 He. Including the effects of rescattering of the outgoing nucleon improves agreement with the data at p miss > 250 MeV/c and suggests contributions from charge-exchange (SCX) rescattering. The isoscalar sum of 3 He plus 3 H, which is largely insensitive to SCX, is described by calculations to within the accuracy of the data over the entire pmiss range. This validates current models of the ground state of the three-nucleon system up to very high initial nucleon momenta of 500 MeV/c.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Erratum: Polarization transfer observables in elastic electron-proton scattering at Q 2 =2.5 , 5.2, 6.8, and 8.5GeV 2 [Phys. Rev. C 96 , 055203 (2017)]

Subsequent to the release of our original paper, we discovered in the context of preparing our technical supplement [1] for journal publication that a typographical error had existed in the text file that the analysis program used to construct the beam polarization "database" for both the original analysis, published in Ref. [2], and our final analysis. The electron-beam polarization P e and the analyzing power A y cancel exactly in the ratio R, which is proportional to the ratio P t / P l of the transferred polarization components. On the other hand, the extraction of the relative e dependence of P l / P Born l relies on knowledge of the beam polarization. As such, data taking was interrupted roughly every two days during the GEp - 2γ experiment to perform invasive measurements of the beam polarization using the Hall C Moller polarimeter [3].

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessments of Potential Rock Coatings at Rocknest, Gale Crater with ChemCam

Many locations on Mars have low color contrast between the rocks and soils due to the rocks being "dusty"--basically having a surface that is spectrally similar to Martian soil. In general this has been interpreted as soil and/or dust clinging to the rock though either mechanical or electrostic processes. However, given the apparent mobility of thin films of water forming cemented soils on Mars and at Gale Crater, the possibility exists that some of these "dusty" surfaces may actually be coatings formed by thin films of water locally mobilizing soil/air fall material at the rock interface. This type of coating was observed by Spirit during an investigation of the rock Mazatzal which showed enhanced salts above "normal soil" and an enhancement of nano phase iron oxide that was ~ 10 micronmeters thick. We decided to use ChemCam to investigate the possibility of similar rock coatings forming at the Rocknest site at Gale Crater.

Gale Crater↗

Characterization of an advanced focal plane for multispectral linear array (MLA) application

It is pointed out that the MLA instrument represents the next generation in the Landsat series of earth resources satellites. The MLA sensor concept utilizes a pushbroom scan mode to eliminate electromechanical scan mirrors, and the lower reliabililty and higher power dissipation which accompany their employment. The pushbroom scanner makes use of a linear array which consists generally of thousands of detectors oriented perpendicular to the along-track direction of the satellite. Test techniques have been developed for the measurement of the module parameters which are critical to MLA focal plane performance. These measurements include the determination of infrared responsivity, linearity over the dynamic range, temporal noise, and fixed pattern effects on each detector element of each module tested. Tests related to spectral response, crosstalk, and spot scan profiles are also conducted. A description is provided of the test equipment involved.

King, P.↗

Vectorcardiographic changes during extended space flight (M093): Observations at rest and during exercise

The objectives of Skylab Experiment M093 were to measure electrocardiographic signals during space flight, to elucidate the electrophysiological basis for the changes observed, and to assess the effect of the change on the human cardiovascular system. Vectorcardiographic methods were used to quantitate changes, standardize data collection, and to facilitate reduction and statistical analysis of data. Since the Skylab missions provided a unique opportunity to study the effects of prolonged weightlessness on human subjects, an effort was made to construct a data base that contained measurements taken with precision and in adequate number to enable conclusions to be made with a high degree of confidence. Standardized exercise loads were incorporated into the experiment protocol to increase the sensitivity of the electrocardiogram for effects of deconditioning and to detect susceptability for arrhythmias.

Smith, R. F.↗

Vectorcardiographic changes during extended space flight

To assess the effects of space flight on cardiac electrical properties, vectorcardiograms were taken on the 9 Skylab astronauts during the flights of 28, 59, and 84 days. The Frank lead system was used and observations were made at rest; during 25%, 50% and 75% of maximum exercise; during a short pulse of exercise (150 watts, 2 minutes); and after exercise. Data from 131 in-flight tests were analyzed by computer and compared to preflight and postflight values. Statistically significant increase in QRS vector magnitude (six of nine crewmen); T vector magnitude (five of nine crewmen); and resting PR interval duration (six of nine crewmen) occurred. During exercise the PR interval did not differ from preflight. Exercise heart rates inflight were the same as preflight, but increased in the immediate postflight period. With the exception of the arrhythmias, no deleterious vectorcardiographic changes were observed during the Skylab missions.

Smith, R. F.↗