Engineering Papers⌕ Search

Engineering topics

Kim, Junyoung

Publications and source records attributed to Kim, Junyoung.

Investigation of a high-temperature combination heat pump for lower-cost electrification in multifamily buildings

The development of space and water heating combination heat pumps capable of generating water temperatures high enough for convective heat emitters will enable more cost-effective and equitable decarbonization solutions for electrifying multifamily buildings. Here, in this paper, multifamily building models and a charge-sensitive mechanistic cycle model of a combination heat pump are developed, and the system performance is predicted based on the models. Unlike other state-of-the-art residential heat pumping equipment, the modeled combination heat pump using an economized, fluid-injected variable-speed compressor can achieve higher temperature lifts of 40° - 85°C, with lower installation costs and complexity. The model predicted heating coefficient of performance (COP h ) is 2.1 at an ambient temperature of -15°C with a high-temperature lift of nearly 85°C, and a seasonal coefficient of performance in heating mode (SCOP h ) ranges from 2 - 4 for different locations. The system shows 30% - 90% lower CO 2 eq emissions over a condensing gas boiler and 9% - 13% lower projected installation costs than two separate space and water heat pumping appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemically driven phase transformation for high-efficiency heat pumping

To reduce energy consumption and improve energy utilization in space conditioning, advanced heat pumping technologies are needed. The chemical looping heat pump (CLHP) is a promising thermodynamic cycle that has theoretically shown the potential to achieve a cooling coefficient of performance (COP c ) increase of over 20% relative to conventional vapor compression systems. In this paper, the key process of the CLHP is experimentally demonstrated, and the system performance and non-ideal behavior are predicted using the component-level models. The results show the feasibility of electrochemical phase change of a working fluid; the peak COP c was 7.64 with a cooling capacity of 3.6 mW (cooling density of 2.57 W m -2 ) at both sink and source temperature of 23°C based on laboratory experiments. The COP c can theoretically reach up to 13 at a temperature lift of 15°C as long as an electrochemical cell can achieve a greater degree of conversion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗