Engineering Papers⌕ Search

Engineering topics

Ketusky, E. T.

Publications and source records attributed to Ketusky, E. T..

Recommendations for DOT 7A Type A Drum Closure and Drop Testing with Additional 49 CFR 173.465(c)(2) Testing and Analysis

The Savannah River National Laboratory (SRNL) is in the process of developing recommendation for the U S. Department of Energy contractors and vendors who want to qualify drums as U S. Department of Transportation (DOT) 7A Type A to meet 49 CFR 173.465 drop testing requirements for fissile and non-ftssile material to maintain containment. Based on the finite element analysis (FEA) models, the safety features suffering the maximum damage that result in loss of containment are identified as the closure ring mechanism (in entirety), the top (mouth area) of the drum, and the lid (including the gasket). The maximum damage is measured in terms of the collective ability of these combined three safety features to maintain containment. As such, both drop testing and FEA were performed to determine the sensitivities of these safety features to drop variations. As part of this effort, a series of physical drop tests and FEAs were conducted at SRNL. These tests used Skolnik drums, CQ5508L (see Attachment 1), which are open DOT 7A Type A open- head carbon steel 208-liter (55-gallon) drums with 12-gauge bolted closure rings. Variables studied were (1) stress relief methods during closure ring installation, (2) content configurations, and (3) drum orientations during a 4-foot free fall. It should be noted that the Skolnik CQ5508L drums have a closure ring with a "V shaped" cross section. (1) The closure testing with analysis confirmed that closure stress relief by rapping is necessary to distribute the closure ring tension around the perimeter and to maintain sufficient closure pre-load for lid retention during 4-foot drops of the heavier packages (500 to 1,000 lbs). It was concluded that no specific style of stress relief is preferred (e g., multi-step rapping/torqueing process, heavy hits vs. light hits, hitting near closure vs. away), as long as no additional change in bolt torque occurs with additional rapping. (2) (3) Modeling indicated that maximum damage is a result of both: (2) content configuration and (3) drop orientation. The worst-case content configuration is one with an eccentrically loaded concentrated content mass. FEA modeling showed that the center- of-gravity over top (CGoT) with the eccentric content on the high side was the orientation of maximum damage relative to drum lid retention. In this content configuration (i.e., CGoT), FEA modeling showed payloads over 500 lbs were required to contain a load distribution plate between content and lid. Both analysis and testing showed the drum with distribution plate can pass the 4-foot CGoT drop.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Test report dot7A type A liquid packaging

This section presents a general description of the DOT Specification 7A Type A liquid content packaging (HVYTAL), the liquid content evaluated as its payload, acceptable payload shipping configurations and features special to its use. This test report documents compliance with the regulatory safety requirements of 49 CFR Parts 173.24, 173.24a, 173.27, 173.410, 173.412, 173.461 – 173.466 and 178.350.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Test report dot 7A type a liquid packaging

This test report documents the performance of Savannah River National Laboratory’s (SRNL’s) U.S. Department of Transportation (DOT) Specification 7A; General Packaging, Type A shielded liquid shipping packaging and compliance with the regulatory requirements of Title 49 of the Code of Federal Regulations (CFR). The primary use of this packaging design is for the transport of radioactive liquids of up to 1.3 liters in an unshielded configuration and up to 113 mL of radioactive liquids in a shielded configuration, with no more than an A2 quantity in either configuration, over public highways and/or commercial aircraft. The contents are liquid radioactive materials sufficiently shielded and within the activity limits specified in173.435 or 173.433 for A2 (normal form) materials, as well as within the analyzed thermal heat limits. Any contents must be compatibly packaged and must be compatible with the packaging. The basic packaging design is based on the U.S. Department of Energy’s (DOE’s) Model 9979 Type A fissile shipping packaging designed and tested by SRNL. The shielded liquid configuration consists of the outer and inner drums of the 9979 package with additional low density polyethylene (LDPE) dunnage nesting a tungsten shielded cask assembly (WSCA) within the 30-gallon inner drum. The packaging model for the DOT Specification 7A, Type A liquids packaging is HVYTAL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Single Stage Contactor Testing Of The Next Generation Solvent Blend

The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility at the Savannah River Site (SRS) is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent to increase the cesium decontamination factor. To support this integration of NGS into the MCU facility the Savannah River National Laboratory (SRNL) performed testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing utilized a blend of BOBCalixC6 based solvent and the NGS with the new extractant, MaxCalix, as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 liquid-to-liquid centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. The results indicate that hydraulically, the NGS solvent performed hydraulically similar to the current solvent which was expected. For the organic carryover 93% of the solvent is predicted to be recovered from the stripping operation and 96% from the extraction operation. As for the mass transfer, the NGS solvent significantly improved the cesium DF by at least an order of magnitude when extrapolating the One-stage results to actual Seven-stage extraction operation with a stage efficiency of 95%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Actual-Waste Testing of Ultraviolet Light to Augment the Enhanced Chemical Cleaning of SRS Sludge

In support of Savannah River Site (SRS) tank closure efforts, the Savannah River National Laboratory (SRNL) conducted Real Waste Testing (RWT) to evaluate Enhanced Chemical Cleaning (ECC), an alternative to the baseline 8 wt% oxalic acid (OA) chemical cleaning technology for tank sludge heel removal. ECC utilizes a more dilute OA solution (2 wt%) and an oxalate destruction technology using ozonolysis with or without the application of ultraviolet (UV) light. SRNL conducted tests of the ECC process using actual SRS waste material from Tanks 5F and 12H. The previous phase of testing involved testing of all phases of the ECC process (sludge dissolution, OA decomposition, product evaporation, and deposition tank storage) but did not involve the use of UV light in OA decomposition. The new phase of testing documented in this report focused on the use of UV light to assist OA decomposition, but involved only the OA decomposition and deposition tank portions of the process. Compared with the previous testing at analogous conditions without UV light, OA decomposition with the use of UV light generally reduced time required to reach the target of <100 mg/L oxalate. This effect was the most pronounced during the initial part of the decomposition batches, when pH was <4. For the later stages of each OA decomposition batch, the increase in OA decomposition rate with use of the UV light appeared to be minimal. Testing of the deposition tank storage of the ECC product resulted in analogous soluble concentrations regardless of the use or non-use of UV light in the ECC reactor.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗