Engineering Papers⌕ Search

Engineering topics

Kempe, Michael D

Publications and source records attributed to Kempe, Michael D.

At least 19 records

Using Meteorological Data to Evaluate Worldwide PV Degradation Rates

Here we automate the process to enable the creation of world maps for specific PV durability metrics. The end goal is to create a tool for the creation of world maps predicting the sensitivity of modules to degradation to inform the development and utilization of module testing standards and to provide information to module designers. TMY (Typical Meteorological Year) Data was aggregated from sites around the world to render insight into factors contributing to the degradation of solar modules. The focus of aggregating data was to create a single dataset to work with utilizing Solar Irradiance values combined with Ambient Temperature, Relative Humidity, Wind Speed and Dew-Point Temperature.

14 SOLAR ENERGY↗

Development of Testing Methods to Predict Cracking in Photovoltaic Backsheets

In recent years there have been some significant failures of photovoltaic backsheets resulting from inadequacies of design that are not detected in current versions of the qualification standards. In some cases, this has resulted in catastrophic failure in less than 5 y of deployment. In this work, we develop a test sample construction and evaluate accelerated exposure conditions necessary to duplicate the cracking field failure of backsheets using a small and manageable coupon. This sample uses a piece of solder wire to put some controlled topology and stress into the backsheet. Through exposure to different environmental stressors it was found that the application of thermal cycling stresses, after ultraviolet radiation exposure, is of primary importance to duplicate field failures.

14 SOLAR ENERGY↗

Reproducing the 'Framing' by a Sequential Stress Test

The 'Framing' (local discoloration along cell edges) was induced by a simple sequential accelerated stress test (consisting of hygrothermal- and UV-stressors) applied to the PV modules with high OTR (oxygen transmission rate) backsheet, irrespective of the inclusion of UV-absorber in poly(ethylene-co-vinyl acetate) (EVA) encapsulant. UV-fluorescence imaging of the PV modules suggests that the spatially-inhomogeneous degradation of EVA material under UV-irradiating conditions is correlated to this 'Framing' indicating an underlying common mechanism. These findings would contribute to the development of test procedures to broadly mimic the actual failures observed in fielded PV.

14 SOLAR ENERGY↗

Generalized Spatio-Temporal Model of Backsheet Degradation From Field Surveys of Photovoltaic Modules

Photovoltaic (PV) module backsheets degrade at different rates because of the specific polymeric materials and the local exposure environments of the installations. Studies of real-world backsheet degradation provide valuable information to understand backsheet degradation and failure. Field surveys of PV module backsheets were conducted on 1310 modules in four commercial PV power plant sites with different exposure times. The backsheet's local exposure environment is determined by its location along the rack length and depth, the modules' elevation above the ground, and the ground cover albedo. Backsheets that are installed at the ends of the module rack length exhibit larger degradation rates (with yellowness index difference of 1.14 $\pm$ 0.45 and 7.80 $\pm$ 1.3 for backsheets of poly (ethylene terephthalate) and poly (ethylene naphthalate) as the air-side layer, respectively) than backsheets in the center section of the rack. A generalized spatio-temporal model was developed to predict the large-scale backsheet degradation of different backsheet polymers across time/age and location in the PV power plant rack. The model utilizes a cubic-spline relationship between backsheet degradation and rack length, and a quadratic relationship between backsheet discoloration and rack depth. This generalized spatio-temporal model predicts the outdoor backsheet degradation with an adjusted- $R^2$ range between 0.31 to 0.89. The similarity between this model and the spatial variation of the rear-side irradiance, indicates that the irradiance plays a significant role in outdoor backsheet degradation. The generalized spatio-temporal model can be used to evaluate large scale PV backsheet performance, as well as a guidance for PV site designers and operations and maintenance crews.

14 SOLAR ENERGY↗

Chapter 11: Combined and Sequential Accelerated Stress Testing for Derisking Photovoltaic Modules

Application of stress factors in the combinations and sequences as they occur in the natural environment better reproduces failures seen in the field. Further, choice of sample type for testing that best represents the final product is most likely to yield relevant results. Tests meeting these criteria are more likely to discover potential weaknesses that are not a priori known in new module designs, reduce risk, accelerate time to market, achieve bankability and reduce costly overdesign.

14 SOLAR ENERGY↗

Degradation in PV Encapsulant Transmittance: Results of the First PVQAT TG5 Study

Reduced optical transmittance of encapsulants resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of service in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. The latest versions of the safety and qualification apply ~40 - ~160 days cumulative dose of the AM1.5G total UV radiation. Essential information that might be used to screen encapsulation through product lifetime also remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding that will be used towards developing a higher fidelity, more rigorous UV weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens were examined at 10 institutions using a variety of indoor chambers (including Xenon, UVA-340, and high pressure mercury light sources). Specimens were artificially weathered for 180 cumulative days at pre-designated accelerated test conditions. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests.

14 SOLAR ENERGY↗

Activation Energy Determination for Photovoltaic Encapsulant Discoloration by Indoor Accelerated UV Testing

A novel methodology for determining the activation energy of photovoltaic encapsulant discoloration using an indoor accelerated ultraviolet (UV) stress test while simultaneously maintaining multiple module temperatures in a single weathering chamber is presented. The testing was performed on some fresh mini-modules with a glass/EVA/cell/EVA/backsheet construction. The short-circuit current degradation from individual cells was used to quantify transmittance losses due to discoloration. Activation energy determined using indoor accelerated UV test data and Modified Arrhenius model ranges from 26 to 44 kJ/mol (0.27 to 0.46 eV). Activation energy was also determined from the outdoor field degradation data by employing different physical models that consider the individual or combined effects of key environmental factors. The approach here is instrumental to evaluating the reliability studies on encapsulant degradation mechanisms using relatively less time and resources.

14 SOLAR ENERGY↗

Using Module Leakage Current Modeling to Understand Corrosion Chemistry

When fielded, modules are exposed to high voltages in the presence of moisture and/or elevated temperature this allows significant leakage currents to flow between the cell and ground. When current changes from an electronic to an ionic form, electrochemical reactions are promoted creating the potential for a wide variety of degradation reactions. This work investigates the nature of this current flow to gain a better understanding of the effect. At the cell surface, current preferentially flows to the metallization and under negative bias will split water to form OH - ions. It is found that transient effects occur in the leakage current as a result of some capacitive and electrochemical effects. This work seeks to provide important insight into the nature of the charge transfer species and the factors that most strongly affect leakage rates to provide better correlation to module performance.

14 SOLAR ENERGY↗

Decoupling Thin Film CdTe Growth from Packaging: Toward Record Specific Power in Low Cost Polycrystalline PV

There are critical material and scientific barriers to producing high efficiency, flexible, lightweight solar cells that maximize specific power in a cost-effective manner. III-V solar cells have produced the highest specific power of any photovoltaic technology due to their extremely high efficiency, however, they are also among the most expensive to produce. This work explores a novel lift-off approach with thin-film solar cells, particularly CdTe, to achieve high specific power at low costs. Thin-film devices can be delaminated from their heavy, glass growth substrates post-growth by exploiting a mismatch in coefficient of thermal expansion between the two. This allows thin-film PV to be decoupled from high temperature growth requirements and repackaged using lightweight materials. In this work we evaluate different materials and approaches for achieving large area delamination of CdTe films from their glass superstrates. It is found that epoxy bonded to a rigid handle provides robust and reproducible delamination at the TCO/CdS interface upon submersion in liquid nitrogen. Following delamination, a transparent front contact is re-deposited and selectively etched to expose the back contact to produce a functioning device. Effects of delamination and contributions to device functionality from CdCl 2 and CdS layers are discussed. Reproducible delamination of high efficiency, thin-film solar cells over large areas will enable work to further improve device efficiency through passivation and reconstruction of the previously buried interface between the transparent contact and CdS.

14 SOLAR ENERGY↗

Survey of Mechanical Durability of PV Backsheets

The ability to maintain mechanical properties after applied environmental stress is a good indicator for long term durability of a backsheet. This work surveys a set of 56 backsheet films, some of which are known to fail in the field and evaluates them utilizing the proposed photovoltaic weathering standard IEC 62788-7-2. While the complete study examined optical reflectance characterization, tensile testing, dielectric testing, and a mandrel bend test, this paper focuses on the mandrel bend test results. All seven of the transparent specimens failed. A polyamide based backsheet known to fail in the field did not fail the bend test. It is believed that the field failure is due to an interaction with the encapsulant and/or the cyclic mechanical exposure experienced in the field. When cracks occur, they happen predominantly in the polyethylene terephthalate for transparent backshees or the 'E' layer for opaque films, never in a fluoropolymer layer.

14 SOLAR ENERGY↗

Photovoltaic Array Differential Backside Exposure Conditions: Backsheet Degradation and Site Design

Backsheet exposure conditions and degradation are shown to vary significantly within an array. This is demonstrated by a survey of the NIST ground-mounted photovoltaic array, which is comprised of over 1000 modules of a single brand with a polyester-based backsheet. Site and array design factors are found to have significant effects on the exposure conditions, and thus degradation of the backsheets. Irradiance is found to be the most significant exposure factor which varies within the array.

14 SOLAR ENERGY↗

Decoupling Thin Film CdTe Growth from Packaging: Toward Record Specific Power in Low Cost Polycrystalline PV: Preprint

There are critical material and scientific barriers to producing high efficiency, flexible, lightweight solar cells that maximize specific power in a cost-effective manner. GaAs solar cells produce the highest specific power of any photovoltaic (PV) technology due to their low weight and extremely high efficiency, but they are also among the most expensive to produce. This work explores a novel lift-off approach with thin-film solar cells, particularly CdTe, to achieve high specific power at low costs. Thin-film devices can be delaminated from their heavy, glass growth substrates post-growth by exploiting a mismatch in coefficient of thermal expansion between the two. This allows thin-film PV to be decoupled from high temperature growth requirements and repackaged using lightweight materials. Currently, the most consistent method of achieving complete delamination of CdTe films is to apply a glass handle at the back contact of the device using epoxy and submerge it in liquid nitrogen. By Tthen re-depositing a transparent front contact but be re-deposited and selectively etcheding to expose the back contact to produce, a functioning lifted-off devices have been produced. Effects of delamination and contributions to device functionality from CdCl2 and CdS layers are discussed. Reproducible delamination of high efficiency, thin-film solar cells over large areas will enable work to further improve device efficiency through passivation and reconstruction of the previously buried interface between the transparent contact and CdS.

14 SOLAR ENERGY↗

Extended Pulse-Powered Humidity-Freeze Cycling for Testing Module-Level Power Electronics

An EMI suppression capacitor (polypropylene film type) failed by 'popcorning' due to vapor outgassing in the pulse powered humidity-freeze cycles. No shorts or shunts could be detected despite mildly corroded metallization visible in the failed capacitor. Humidity-freeze cycling is optimized to break into moisture barriers. However, further studies will done on additional MLPE devices to optimize the stress testing for condensation to precipitate any weakness to short circuiting and other humidity/bias failure modes.

14 SOLAR ENERGY↗

Potential-Induced Degradation-Delamination Mode in Crystalline Silicon Modules: Preprint

A test sequence producing potential-induced degradation-delamination (PID-d) in crystalline silicon modules has been tested and found comparable under visual inspection to cell/encapsulant delamination seen in some fielded modules. Four commercial modules were put through this sequence, 85 degrees C, 85%, 1000 h damp heat, followed by an intensive PID stress sequence of 72 degrees C, 95% RH, and -1000 V, with the module face grounded using a metal foil. The 60 cell c-Si modules exhibiting the highest current transfer (4.4 center dot 10-4 A) exhibited PID-d at the first inspection after 156 h of PID stress. Effects promoting PID-d are reduced adhesion caused by damp heat, sodium migration further reducing adhesion to the cells, and gaseous products of electrochemical reactions driven by the applied system voltage. A new work item proposal for an IEC test standard to evaluate for PID-d is anticipated.

14 SOLAR ENERGY↗

Extended Pulse-Powered Humidity-Freeze Cycling for Testing Module-Level Power Electronics

An EMI suppression capacitor (polypropylene film type) failed by 'popcorning' due to vapor outgassing in pulse powered humidity-freeze cycles. No shorts or shunts could be detected despite mildly corroded metallization visible in the failed capacitor. Humidity-freeze cycling is optimized to break into moisture barriers. However, further studies will be required on additional module level power electronic (MLPE) devices to optimize the stress testing for condensation to precipitate any weakness to short circuiting and other humidity/bias failure modes.

14 SOLAR ENERGY↗

Qualification Testing Versus Quantitative Reliability Testing of PV - Gaining Confidence in a Rapidly Changing Technology: Preprint

Continued growth of PV system deployment would be enhanced by quantitative, low-uncertainty predictions of the degradation and failure rates of PV modules and systems. The intended product lifetime (decades) far exceeds the product development cycle (months), limiting our ability to reduce the uncertainty of the predictions for this rapidly changing technology. Yet, business decisions (setting insurance rates, analyzing return on investment, etc.) require quantitative risk assessment. Moving toward more quantitative assessments requires consideration of many factors, including the intended application, consequence of a possible failure, variability in the manufacturing, installation, and operation, as well as uncertainty in the measured acceleration factors, which provide the basis for predictions based on accelerated tests. As the industry matures, it is useful to periodically assess the overall strategy for standards development and prioritization of research to provide a technical basis both for the standards and the analysis related to the application of those. To this end, this paper suggests a tiered approach to creating risk assessments. Recent and planned potential improvements in international standards are also summarized.

14 SOLAR ENERGY↗

Degradation Analysis of Field-Exposed Photovoltaic Modules with Non-Fluoropolymer-Based Backsheets

The selection of polymeric materials utilized in photovoltaic (PV) modules has changed relatively little since the inception of the PV industry, with ethylene-vinyl acetate (EVA), polyethylene terephthalate (PET), and fluoropolymer-based laminates being the most widely adopted primary components of the encapsulant and backsheet materials. The backsheet must serve to electrically insulate the solar cells and protect them from the effects of weathering. Due to continued downward pressure on cost, other polymeric materials are being formulated to withstand outdoor exposure for use in backsheets to replace either the PET film, the fluoropoymer film, or both. Because of their relatively recent deployment, less is known about their reliability and if they are durable enough to fulfill the greater than or equal to 25 year warranties of current PV modules. This work presents a degradation analysis of field-exposed modules with polyamide- and polyester-based backsheets. Modules were exposed for up to five years in different geographic locations: USA (Maryland, Ohio), China, and Italy. Surface and cross-sectional analysis included visual inspection, colorimetry, glossimetry, and Fourier-transform infrared spectroscopy. Each module experienced different types of degradation depending on the exposure site, even for the same material and module brand. For instance, the polyamide-based backsheet experienced hairline cracking and greater yellowing and chemical changes in China (Changsu, humid subtropical climate), while in Italy (Rome, hot-summer Mediterranean climate) it underwent macroscopic cracking and greater losses in gloss. Spectroscopic studies have permitted identification of degradation products and changes in polymer structure over time. Comparisons are made to fielded modules with fluoropolymer-based backsheets, as well as backsheet materials in accelerated laboratory exposures. Implications for qualification testing and service life prediction of the non-fluoropolymer-based backsheets are discussed.

14 SOLAR ENERGY↗

Model Development of Degradation of PV Modules Backsheet with Locating Place of Module

Performance of a photovoltaic (PV) module is related to the micro-environment around the module. The position of photovoltaic modules in an array row have a large effect on the yellowing and gloss of PV module backsheet exposed in Dfa climatic zone (Gaithersburg, MD) with a polyethylene naphthalate (PEN) outer layer. Stress/Response models of yellowing and gloss-losing as function of location parameters of module, including the shed, row, measurement position in a same module and the distance of module location to the row center, are under development. The module installation height had the greatest influence on degradation of PEN PV backsheet in the Dfa climatic zone. The module backsheets at the end of an array have higher degradation rate (edge effect). The edge effect decreases with increasing of module installation heights.

14 SOLAR ENERGY↗