Chemical sensing and imaging in microfluidic pore network structures relevant to natural carbon cycling and industrial carbon sequestration

Energy and climate change represent significant factors in global security. Atmospheric carbon dioxide levels, while global in scope, are influenced by pore-scale phenomena in the subsurface. We are developing tools to visualize and investigate processes in pore network microfluidic structures with transparent covers as representations of normally-opaque porous media. In situ fluorescent oxygen sensing methods and fluorescent cellulosic materials are being used to investigate processes related to terrestrial carbon cycling involving cellulytic respiring microorganisms. These structures also enable visualization of water displacement from pore spaces by hydrophobic fluids, including carbon dioxide, in studies related to carbon sequestration.

carbon sequestration↗

Microchip capillary electrophoresis absent electrokinetic injection

Microchip capillary electrophoresis (CE) utilizing a sample injector based on a mechanical valve rather than electrokinetic injection can provide improved sample injections, enhanced capabilities, and can eliminate the need for changing the electric field in the separation channel to induce sample injection. In one instance CE electrodes continuously apply an electric field for CE separation along a separation channel. A sample channel is connected to the separation channel at an intersection and has a sample pressure that is greater than that which is present in the separation channel near the intersection. The sample channel does not have electrodes that apply voltages for electrokinetic injection. A sample injector in the sample channel or at the intersection comprises a mechanical valve to control sample injection from the sample channel to the separation channel.

Sun, Xuefei↗

EMSL Pore Scale Modeling Challenge/Workshop

The design and implementation of cost-effective remediation strategies for subsurface contamination not only relies on descriptive models of contaminant distribution but predictive models of contaminant fate and transport. The development of such predictive models is of great importance to many government agencies including the Department of Energy (DOE), Department of Defense, and the Environmental Protection Agency. Accurate prediction of the fate and transport of environmental contaminants in the subsurface has driven development of increasingly sophisticated subsurface flow and transport models. Even without considering spatial and temporal scalability, contaminant transport at the field scale is complex, and this almost inevitably results in an especially sophisticated model being developed for a specific field site. Unfortunately, these models are not easily generalizable to other field sites or and can only be used by the model authors to generate meaningful results. Over time, this results in the existence of numerous specialized models that are not readily comparable to each other and difficult to cross-validate. There is a lack of fundamental experimental observations at the pore scale that can be used to support model development and validation at the field scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analytical Characterization of the Electrospray Ion Source in the Nanoflow Regime

We provide a thorough characterization of the low-flow electrospray as an ionization source for mass spectrometry (MS) using solutions typical for reversed-phase liquid chromatography. As expected, the electrospray operating regime strongly affects the MS signal; however, contrary to conventional wisdom, the pulsating regime consistently offers better performance than the cone-jet regime in these experimental conditions. We explain this observation by a highly efficient ionization achieved by the pulsating electrospray at low flow rates, rendering the increased charge generated by a cone-jet electrospray detrimental for transmission from atmospheric pressure to vacuum through a heated capillary interface. Over a wide range of voltages, the pulsating electrospray provides a relatively constant MS signal intensity, which depends significantly on the distance between the emitter and the MS inlet. For cone-jet electrosprays the MS signal decreases slightly with increasing voltage, but the signal is less affected by the emitter-inlet distance. At flow rates up to 100 nL/min the MS signal increases with increasing flow rate due to the larger number of ions supplied into the gas phase. At flow rates greater than 100 nL/min, the signal reaches a plateau due to increasingly unsatisfactory ionization efficiency at larger flow rates.

Environmental Molecular Sciences Laboratory↗

Nanoelectrospray Emitter Arrays Providing Interemitter Electric Field Uniformity

Arrays of electrospray ionization (ESI) emitters have been reported previously as a means of achieving the enhanced ionization efficiencies. A key challenge when working with multiple, closely spaced ESI emitters is overcoming the deleterious effects caused by electrical interference among neighboring emitters. Individual emitters experience different electric fields depending on their relative position in the array, such that it becomes difficult to operate all of the emitters optimally for a given applied potential. In this work, we have developed multi-nanoESI emitters arranged with a circular pattern, which enable the constituent emitters to experience a uniform electric field. The performance of the circular emitter array was compared to a single emitter and to a previously developed linear emitter array, which verified that improved electric field uniformity was achieved with the circular arrangement. The circular arrays were also interfaced with a mass spectrometer via a matching multi-capillary inlet, and the results were compared with those obtained using a single emitter. By minimizing inter-emitter electric field inhomogeneities, much larger arrays having closer emitter spacing should be feasible.

Kelly, Ryan T.↗

Elastomeric Microchip Electrospray Emitter for Stable Cone-Jet Mode Operation in the Nanoflow Regime.

Despite widespread interest in applying lab-on-a-chip technologies to mass spectrometry (MS)-based analyses, the coupling of microfluidics to electrospray ionization (ESI)-MS remains challenging. We report a robust, integrated poly(dimethylsiloxane) microchip interface for ESI-MS using simple and widely accessible microfabrication procedures. The interface uses an auxiliary channel to provide electrical contact in the Taylor cone of the electrospray without sample loss or dilution. The electric field at the channel terminus is enhanced by two vertical cuts that cause the interface to taper to a line rather than to a point, and the formation of small Taylor cones at the channel exit ensures sub-nL post-column dead volumes. While comparable ESI-MS sensitivities were achieved using both microchip and conventional fused silica capillary emitters, stable cone-jet mode electrospray could be established over a far broader range of flow rates (from 50–1000 nL/min) and applied potentials using the microchip emitters. This special feature of the microchip emitter should minimize the fine tuning required for electrospray optimization and make the stable electrospray more resistant to external perturbations.

Kelly, Ryan T.↗

A subambient pressure ionization with nanoelectrospray (SPIN) source and interface for improved sensitivity in mass spectrometry

Subambient Pressure Ionization with Nanoelectrospray (SPIN), an electrospray ionization source that operates at 30 Torr inside the first vacuum chamber of a mass spectrometer, has been demonstrated for reversed-phase liquid chromatography-mass spectrometry analysis of a protein tryptic digest solution. A 5–12-fold improvement in sensitivity relative to a standard atmospheric pressure ESI source was observed for a variety of detected peptides. The low liquid chromatographic flow rate (300 nL/min) allowed stable electrospray to be established before the onset of electrical discharge, and the higher operating pressure of the SPIN source relative to previous low-pressure ESI source designs prevented the solvents from freezing. The range of accessible flow rates for the SPIN source was also extended to 2.5 μL/min by using an array of electrospray emitters that divided the flow to 6 discrete electrosprays.

59 BASIC BIOLOGICAL SCIENCES↗