Engineering Papers⌕ Search

Engineering topics

Kelly, Ryan T.

Publications and source records attributed to Kelly, Ryan T..

At least 37 records · Page 2

Automated Nanoflow Two-Dimensional Reversed-Phase Liquid Chromatography System Enables In-Depth Proteome and Phosphoproteome Profiling of Nanoscale Samples

Two-dimensional reversed-phase liquid chromatography (2D RPLC) separations have enabled near-comprehensive proteome profiling of biological systems. However, large samples containing milligram amounts of protein are usually required due to the significant sample losses incurred during offline fractionation. The large sample requirements preclude the application of 2D RPLC to biological systems having sample availability in the nanogram to low-microgram range. To achieve in-depth proteomic studies of trace samples, we have developed an automated nanoflow 2D RPLC platform in which the first dimension high-pH fractionation was performed at 300 nL/min on a 75-µm i.d. capillary column.Each fraction was then fully transferred to a second-dimension nanoLC separation using an autosampler equipped with a custom-machined syringe. In addition to optimizing fractionation conditions, we found that the use of a plastic 96-well plate as collection device and the adding of n-Dodecyl ß-D-Maltoside (0.01%) in the collection buffer can significantly improve sample recovery. We have demonstrated the nanoflow 2D RPLC platform can achieve confident identifications of ~37,000–69,000 unique peptides, corresponding to ~5300–6900 protein groups using only 100 to 1000 ng of HeLa tryptic digest. Furthermore, by integrating phosphopeptide enrichment, the platform can identify as many as ~20,000 phosphopeptides from 100 µg of MCF7 protein digest. Because this platform is assembled from commercially available components, our approach can be readily adapted in other proteomics laboratories.

Mass spectrometry, multidimensional separations, n↗

Nanowell-mediated multidimensional separations combining nanoLC with SLIM IM-MS for rapid, high-peak-capacity proteomic analyses

Mass spectrometry (MS)–based analysis of complex biological samples is essential for biomedical research and clinical diagnostics. The separation prior to MS plays a key role in the overall analysis, with separations having larger peak capacities often leading to more identified species and improved confidence in those identifications. High-resolution ion mobility (IM) separations enabled by Structures for Lossless Ion Manipulation (SLIM) can provide extremely rapid, high-resolution separations and are well suited as a second dimension of separation following nanoscale liquid chromatography (nanoLC). However, existing sample handling approaches for offline coupling of separation modes require microliter-fraction volumes and are thus not well suited for analysis of trace biological samples. We have developed a novel nanowell-mediated fractionation system that enables nanoLC-separated samples to be efficiently preconcentrated and directly infused at nanoelectrospray flow rates for downstream analysis. When coupled with SLIM IM-MS, the platform enables rapid and high-peak-capacity multidimensional separations of small biological samples. In this study, peptides eluting from a 100 nL/min nanoLC separation were fractionated into ~?60 nanowells on a microfluidic glass chip using an in-house–developed robotic system. The dried samples on the chip were individually reconstituted and ionized by nanoelectrospray for SLIM IM-MS analysis. Using model peptides for characterization of the nanowell platform, we found that at least 80% of the peptide components of the fractionated samples were recovered from the nanowells, providing up to ~tenfold preconcentration for SLIM IM-MS analysis. The combined LC-SLIM IM separation peak capacities exceeded 3600 with a measurement throughput that is similar to current one-dimensional (1D) LC-MS proteomic analyses.

Dou, Maowei↗

Ultrasmall sample biochemical analysis

Richard Feynman’s landmark lecture from 1959 titled BThere’s Plenty of Room at the Bottom: An Invitation to Enter a New Field of Physics^ is widely known for encouraging research into the field we now refer to as nanotechnology. In that same lecture, he also presciently recognized that many fundamental questions in biology could be answered through miniaturization, particularly using microscopy, noting that many knowledge gaps could be readily addressed if we could Bjust look at the thing!^ Indeed, increasing the resolution with which biological systems are investigated, whether it be through cryoelectron microscopy, flow cytometry, or singlecell RNA-Seq, has revolutionized many aspects of biological inquiry. In this themed topical collection of Analytical and Bioanalytical Chemistry, we emphasize that there is still Bplenty of room at the bottom^ when it comes to biochemical analysis. Great strides have been made in biology and medicine as chemical measurements that have historically been applied to bulk tissues are extended to the scale at which the biology is occurring, which is often at the cellular or subcellular level.

Kelly, Ryan T.↗

Microfluidic Sensors with Impregnated Fluorophores for Simultaneous Imaging of Spatial Structure and Chemical Oxygen Gradients

Inside surfaces of polystyrene microfluidic structures were impregnated with the oxygen sensing dye (PtTFPP) using a solvent-induced fluorophore impregnation (SIFI) method. By this technique, microfluidic oxygen sensors are obtained that enable simultaneous imaging of both chemical oxygen gradients and the physical structure of the microfluidic interior. A gentle method of fluorophore impregnation using acetonitrile solutions of PtTFPP at 50oC was developed leading to 10 micron deep region containing fluorophore. This region is localized at the surface to sense oxygen in the interior fluid during use. Regions of the device that do not contact the interior fluid pathways lack fluorophores and are dark in fluorescent imaging. The technique was demonstrated on straight microchannel and pore network devices, the latter having pillars of 300 µm diameter spaced center to center at 340 µm providing pore throats of 40 µm. Sensing within channels or pores, and imaging across the pore network devices were performed using a Lambert LIFA-P frequency domain fluorescence lifetime imaging system on a Leical microscope platform. Calibrations of different devices prepared by the SIFI method were indistinguishable. Gradient imaging showed fluorescent regions corresponding to the fluid pore network, dark pillars, and fluorescent lifetime varying across the gradient, thus providing both physical and chemical imaging. More generally, the SIFI technique can impregnate the interior surfaces of other polystyrene containers, such as cuvettes or cell and tissue culture containers, to enable sensing interior conditions.

microfluidic, sensor, imaging, oxygen↗

Benchtop-compatible sample processing workflow for proteome profiling of < 100 mammalian cells

Extending proteomics to smaller samples can enable the mapping of protein expression across tissues with high spatial resolution and can reveal sub-group heterogeneity. However, despite the continually improving sensitivity of LC-MS instrumentation, in-depth profiling of samples containing low-nanogram amounts of protein has remained challenging due to analyte losses incurred during preparation and analysis. To address this, we recently developed nanodroplet processing in one pot for trace samples (nanoPOTS), a robotic/microfluidic platform that generates ready-to-analyze peptides from cellular material in ~200 nL droplets with greatly reduced sample losses. In combination with ultrasensitive LC-MS, nanoPOTS has enabled >3000 proteins to be confidently identified from as few as 10 cultured human cells and ~700 proteins from single cells. However, the nanoPOTS platform requires a highly skilled operator and a costly in-house-built robotic nanopipetting instrument. In this work, we sought to evaluate the extent to which the benefits of nanodroplet processing could be preserved when upscaling reagent dispensing volumes by a factor of 10 to those addressable by commercial micropipette. We characterized the resulting platform, termed microdroplet processing in one pot for trace samples (µPOTS), for the analysis of as few as ~25 cultured HeLa cells (4 ng total protein) or 50 µm square mouse liver tissue thin sections and found that ~1800 and ~1200 unique proteins were respectively identified with high reproducibility. As such, the reduced equipment requirements should facilitate broad dissemination of nanoproteomics workflows by obviating the need for a capital-intensive custom liquid handling system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoproteomics Comes of Age

Substantial technological advances have been made towards making enabling a nanoproteomics capability, i.e., quantitative proteome profiling of small cell populations (<5000 cells). These advances include new technologies or approaches from all areas of the overall proteomics workflow ranging from sample isolation, sample processing, high resolution separations, MS detection, to informatics. Herein we present a brief review of the recent technological advances, the current state of nanoproteomics, and future perspectives on both the technological direction and potential enabling applications.

Nanoproteomics, small cell populations, single cel↗

Proteome Profiling of 1 to 5 Spiked Circulating Tumor Cells Isolated from Whole Blood Using Immunodensity Enrichment, Laser Capture Microdissection, Nanodroplet Sample Processing, and Ultrasensitive nanoLC–MS

Proteome profiling of circulating tumor cells (CTCs) can provide crucial insight into disease progression and the role of CTCs in tumor metastasis. We describe an integrated workflow to measure global protein expression in 1–5 spiked CTCs enriched from whole blood by immunodensity gradient centrifugation. Enriched CTCs were purified and collected by laser capture microdissection, prepared using a recently developed nanodroplet-based processing platform (nanoPOTS), and finally analyzed by ultrasensitive nanoLC–MS/MS. The workflow was capable of identifying an average of 164 and 607 protein groups from samples comprising 1 and 5 LNCaP cells, respectively, that were isolated from human whole blood. A panel of prostate cancer-specific proteins were identified and quantified, which was used to differentiate between spiked CTCs and white blood cells.

Zhu, Ying↗

Spatially Resolved Proteome Profiling of <200 Cells from Tomato Fruit Pericarp by Integrating Laser-Capture Microdissection with Nanodroplet Sample Preparation

Due to sensitivity limitations, global proteome measurements generally require large amounts of biological starting material, which masks heterogeneity within the samples and differential protein expression among constituent cell types. Methods for spatially-resolved proteomics are being developed to resolve protein expression for distinct single cell types among highly heterogeneous tissues, but have primarily been applied to mammalian systems. Here we evaluate the performance of cell-type-specific proteome analysis of tomato fruit pericarp tissues by a platform integrating laser capture microdissection (LCM) and a recently developed automated sample preparation system (nanoPOTS, Nanodroplet processing in One pot for Trace Samples). Tomato fruits were cryosectioned prior to LCM, and tissues were dissected and captured directly into nanoPOTS chips for processing. Following processing, samples were analyzed by nanoLC-MS/MS. Approximately 1900 unique peptides and 422 proteins were identified on average from ~0.04 mm2 tissues comprising ~ 8-15 parenchyma cells. Spatially-resolved proteome analyses were performed using cells of outer epidermis, collenchyma, and parenchyma. Using =200 cells, a total of 1,870 protein groups were identified and the various tissues were easily resolved. The results provide spatial and tissue-specific insights into key enzymes and pathways involved in carbohydrate transport and source-sink relationships in tomato fruit. Of note, at the time of fruit ripening studied here, we identified differentially abundant proteins throughout the pericarp related to chlorophyll biogenesis, photosynthesis, and especially transport.

Liang, Yiran↗

Proteomic Analysis of Single Mammalian Cells Enabled by Microfluidic Nanodroplet Sample Preparation and Ultrasensitive NanoLC-MS

We report on the quantitative proteomic analysis of single mammalian cells. Fluorescence-activated cell sorting was used to deposit cells into a nanodroplet system for proteomic sample preparation. After processing, samples were analysed by ultrasensitive nanoLC-MS. Using this platform, an average of ~670 protein groups were identified from single HeLa cells and ~330 proteins were quantifiable. We demonstrated the single cell proteomics platform can be used to differentiate cell types from enzyme-dissociated primary cells from human lung and identify specific protein marker among them.

Zhu, Ying↗

The role of electron irradiation history in liquid cell transmission electron microscopy

In situ liquid cell transmission electron microscopy (LC-TEM) allows dynamic nanoscale characterization of systems in a hydrated state. Although powerful, this technique remains impaired by issues of repeatability that limit experimental fidelity and hinder the identification and control of some variables underlying observed dynamics. We detail new LC-TEM devices that improve experimental reproducibility by expanding available imaging area and providing a platform for investigating electron flux history on the sample. Irradiation history is an important factor influencing LC-TEM results that has, to this point, been largely qualitatively and not quantitatively described. We use these devices to highlight the role of cumulative electron flux history on samples from both nanoparticle growth and biological imaging experiments and demonstrate capture of time zero, low-dose images on beam-sensitive samples. In particular, the ability to capture pristine images of biological samples, where the acquired image is the first time that the cell experiences significant electron flux, allowed us to determine that nanoparticle movement compared to the cell membrane was a function of cell damage and therefore an artifact rather than visualizing cell dynamics in action. Lastly, these results highlight just a subset of the new science that is accessible with LC-TEM through the new multiwindow devices with patterned focusing aides.

59 BASIC BIOLOGICAL SCIENCES↗

Subnanogram proteomics: Impact of LC column selection, MS instrumentation and data analysis strategy on proteome coverage for trace samples

One of the greatest challenges for mass spectrometry (MS)-based proteomics is the limited ability to analyze small samples. Here we investigate the relative contributions of liquid chromatography (LC), MS instrumentation and data analysis methods with the aim of improving proteome coverage for sample sizes ranging from 0.5 ng to 50 ng. We show that the LC separations utilizing 30-µm-i.d. columns increase signal intensity by >3-fold relative to those using 75-µm-i.d. columns, leading to 32% increase in peptide identifications. The Orbitrap Fusion Lumos mass spectrometer significantly boosted both sensitivity and sequencing speed relative to earlier generation Orbitraps (e.g., LTQ-Orbitrap), leading to a ~3× increase in peptide identifications and 1.7× increase in identified protein groups for 2 ng tryptic digests of bacterial lysate. The Match Between Runs algorithm of open-source MaxQuant software further increased proteome coverage by ~ 95% for 0.5 ng samples and by ~42% for 2 ng samples. The present platform is capable of identifying >3000 protein groups from tryptic digestion of cell lysates equivalent to 50 HeLa cells and 100 THP-1 cells (~10 ng total proteins), respectively, and >950 proteins from subnanogram bacterial and archaeal cell lysates. The present ultrasensitive LC-MS platform is expected to enable deep proteome coverage for subnanogram samples, including single mammalian cells.

Environmental Molecular Sciences Laboratory↗

Nanodroplet processing platform for deep and quantitative proteome profiling of 10–100 mammalian cells

Nanoscale or single cell technologies are critical for biomedical applications. However, current mass spectrometry (MS)-based proteomic approaches require samples comprising a minimum of thousands of cells to provide in-depth profiling. Here, we report the development of a nanoPOTS (Nanodroplet Processing in One pot for Trace Samples) platform as a major advance in overall sensitivity. NanoPOTS dramatically enhances the efficiency and recovery of sample processing by downscaling processing volumes to <200 nL to minimize surface losses. When combined with ultrasensitive LC-MS, nanoPOTS allows identification of ~1500 to ~3,000 proteins from ~10 to ~140 cells, respectively. By incorporating the Match Between Runs algorithm of MaxQuant, >3000 proteins were consistently identified from as few as 10 cells. Furthermore, we demonstrate robust quantification of ~2400 proteins from single human pancreatic islet thin sections from type 1 diabetic and control donors, illustrating the application of nanoPOTS for spatially resolved proteome measurements from clinical tissues.

Environmental Molecular Sciences Laboratory↗

A Customizable Flow Injection System for Automated, High Throughput, and Time Sensitive Ion Mobility Spectrometry and Mass Spectrometry Measurements

To better understand disease conditions and environmental perturbations, multi-omic studies (i.e. proteomic, lipidomic, metabolomic, etc. analyses) are vastly increasing in popularity. In a multi-omic study, a single sample is typically extracted in multiple ways and numerous analyses are performed using different instruments. Thus, one sample becomes many analyses, making high throughput and reproducible evaluations a necessity. One way to address the numerous samples and varying instrumental conditions is to utilize a flow injection analysis (FIA) system for rapid sample injection. While some FIA systems have been created to address these challenges, many have limitations such as high consumable costs, low pressure capabilities, limited pressure monitoring and fixed flow rates. To address these limitations, we created an automated, customizable FIA system capable of operating at diverse flow rates (~50 nL/min to 500 µL/min) to accommodate low- and high-flow instrument sources. This system can also operate at varying analytical throughputs from 24 to 1200 samples per day to enable different MS analysis approaches. Applications ranging from native protein analyses to molecular library construction were performed using the FIA system. The results from these studies showed a highly robust platform, providing consistent performance over many days without carryover as long as washing buffers specific to each molecular analysis were utilized.

Orton, Daniel J.↗

Multimodal microfluidic platform for controlled culture and analysis of unicellular organisms

Modern live-cell imaging approaches permit real-time visualization of biological processes, yet limitations exist for unicellular organism isolation, culturing and long-term imaging that preclude fully understanding how cells sense and respond to environmental perturbations and the link between single-cell variability and whole-population dynamics. Here we present a microfluidic platform that provides fine control over the local environment with the capacity to replace media components at any experimental time point, and provides both perfused and compartmentalized cultivation conditions depending on the valve configuration. In this work, the functionality and flexibility of the platform were validated using both bacteria and yeast having different sizes, motility and growth media. The demonstrated ability to track the growth and dynamics of both motile and non-motile prokaryotic and eukaryotic organisms emphasizes the versatility of the devices, which with further scale-up should enable studies in bioenergy and environmental research.

59 BASIC BIOLOGICAL SCIENCES↗

Direct Surface and Droplet Microsampling for Electrospray Ionization Mass Spectrometry Analysis with an Integrated Dual-Probe Microfluidic Chip

Ambient mass spectrometry (MS) has revolutionized the way of MS analysis and broadened its application in various fields. This paper describes the use of microfluidic techniques to simplify the setup and improve the functions of ambient MS by integrating the sampling probe, electrospray emitter probe, and online mixer on a single glass microchip. Two types of sampling probes, including a parallel-channel probe and a U-shaped channel probe, were designed for dryspot and liquid-phase droplet samples, respectively. We demonstrated that the microfabrication techniques not only enhanced the capability of ambient MS methods in analysis of dry-spot samples on various surfaces, but also enabled new applications in the analysis of nanoliter-scale chemical reactions in an array of droplets. The versatility of the microchip-based ambient MS method was demonstrated in multiple different applications including evaluation of residual pesticide on fruit surfaces, sensitive analysis of low-ionizable analytes using postsampling derivatization, and high-throughput screening of Ugi-type multicomponent reactions.

Huang, Cong-Min↗

Multimodal Microchannel and Nanowell-Based Microfluidic Platforms for Bioimaging

Modern live-cell imaging approaches permit real-time visualization of biological processes. However, limitations for unicellular organism trapping, culturing and long-term imaging can preclude complete understanding of how such microorganisms respond to perturbations in their local environment or linking single-cell variability to whole population dynamics. We have developed microfluidic platforms to overcome prior technical bottlenecks to allow both chemostat and compartmentalized cellular growth conditions using the same device. Additionally, a nanowell-based platform enables a high throughput approach to scale up compartmentalized imaging optimized within the microfluidic device. These channel and nanowell platforms are complementary, and both provide fine control over the local environment as well as the ability to add/replace media components at any experimental time point.

bioimaging↗