A Surveillance Program is in place to assess how nuclear material storage containers at LANL are aging in-service. This program is guided by the LANL Surveillance Plan which is required by DOE M441.1-1. The plan is modified as necessary to ensure that any issues identified during surveillance or laboratory studies are examined in future surveillances, and that any lifetime implications are taken into account. Under the plan, overall container integrity is evaluated by a combination of visual inspections and photographs. Multiple measurements are made to assess the SAVY 4000 performance, including, helium leakage rate, O-ring hardness (durometer), O-ring compression set, filter performance and filter water resistance. The containers for surveillance are chosen annually based on the previous surveillance program results and observations. The surveillance plan targets items believed to provide the greatest challenge to the SAVY 4000 container integrity.
Abstract not provided.
This document describes LANL Storage Program best practices when working with other User Sites to implement DOE M441.1-1 Manual requirements through the use of the SAVY nuclear material packaging system. It is a Manual directive for Field Element Managers to review and approve the SAVY-4000 container series design (with supporting technical basis) as a packaging system for use at their respective sites. This review and approval incorporates an evaluation of the User Site methodology for SAVY surveillance and the process for documenting its nuclear materials storage program. This document aims to assist the Field Element Mangers and User Sites in the processes necessary to credit LANL SAVY surveillance for key elements of the User Site surveillance plan.
This white paper proposes a Hagan-specific surveillance plan. Currently, Hagan containers are examined on an ad hoc basis as part of the SAVY-4000 surveillance plan. Given the size, aging horizon, and unique potential failure mechanisms of the Hagan population, the authors believe there is a need to have a Hagan-specific surveillance plan.
The crack detection algorithm steps are defined and examples are shown.
Parameter settings and montages are reviewed and ranked for the pit and crack detection summary.
Nuclear material packages, with few exceptions, outside of an approved engineered contamination barrier must meet packaging, surveillance, and testing requirements designed to protect workers from airborne contamination per Department of Energy (DOE) Manual 441.1-1, Nuclear Material Packaging. The SAVY-4000 containers were developed at Los Alamos National Laboratory (LANL) in conjunction with Nuclear Filter Technology Inc. (NFT Inc.) as a general purpose vented manually-compliant container system for staging and storage of plutonium for LANL and the DOE complex. The SAVY-4000 containers have a 316L stainless steel containment barrier, which was selected based on its corrosion resistant properties. These containers were approved for use in 2014 with a five-year design life; LANL requested and DOE has approved lifetime extension from 5 to 15 years. The 10-year lifetime extension was proposed as a conservative recommendation based on the corrosion observations for the metal components in surveillance and results from laboratory studies. Extensive accelerated aging studies have been done on the SAVY-4000 O-ring with very little evidence of significant degradation when subjected to aggressive elevated temperature and radiation conditions. Therefore, our current conservative lifetime estimate for the O-ring and the filter is 40 years at 80°C. Additional work is ongoing in a phased approach to further extend the design life of the Manual compliant SAVY-4000 storage container; the limiting component for further life extension is still the 316L containment barrier.
The Packaging Surveillance Program section of the Department of Energy (DOE) Manual 441.1-1, Nuclear Material Packaging Manual (DOE 2008), requires DOE contractors to “ensure that a surveillance program is established and implemented to ensure the nuclear material storage package continues to meet its design criteria.” The Los Alamos National Laboratory (LANL) SAVY-4000 Field Surveillance Plan was first issued in fiscal year (FY) 2013. The surveillance plan is reviewed annually and updated as necessary based on SAVY-4000 surveillance findings, as well as results of the lifetime extension studies. Five surveillance plan updates have been issued, one in 2014, one in 2016, one in 2017, one in 2018, and one in 2019. This 2020 update documents what was actually done in 2019 and what is planned for 2020. Deviations from the 2019 surveillance plan were necessary because some of the planned surveillance containers were not available for examination. The goal of the surveillance program is to provide data to: evaluate container component performance over time against the initial baseline qualification; validate the current SAVY container design life; provide data for future design life extensions of components as indicated; identify indications of container degradation early and identify similar containers and/or contents that may need remediation; maintain and continuously improve the surveillance information system that documents the complete life cycle of the containers including the initial production baseline, usage history, surveillance, and disposition; identify container issues related to wear and tear that could indicate the need for a maintenance program for in-service containers prior to the end of the design life.
A Surveillance Program is in place to assess how nuclear material storage containers at LANL are aging in-service. This program is guided by the LANL Surveillance Plan which is required by DOE M441.1-1. The plan is modified as necessary to ensure that any issues identified during surveillance or laboratory studies are examined in future surveillances, and that any lifetime implications are taken into account. Under the plan, overall container integrity is evaluated by a combination of visual inspections and photographs. Multiple measurements are made to assess the SAVY 4000 performance, including, helium leakage rate, O-ring hardness (durometer), O-ring compression set, filter performance and filter water resistance. The containers for surveillance are chosen annually based on the previous surveillance program results and observations. The surveillance plan targets items believed to provide the greatest challenge to the SAVY 4000 container integrity.
This report provides an update of the FY19 corrosion observations, laboratory studies, and mitigation efforts for the nuclear material storage program at Los Alamos National Laboratory. Nuclear material packages outside of an approved engineered contamination barrier must meet packaging, surveillance, and testing requirements designed to protect workers from airborne contamination per Department of Energy (DOE) Manual 441.1-1, Nuclear Material Packaging.1 The SAVY-4000 containers were developed at Los Alamos National Laboratory (LANL) in conjunction with Nuclear Filter Technology as a manually-compliant container system for staging and storage of plutonium for LANL and the DOE complex.
Contained in this report is a description of the 3013 inner container lid leak detection system, a listing of the data collected to validate the system and a statistical analysis of collected data. The 3013 Container Surveillance Program provides assessment criteria and evaluates 3013 containers selected from the storage inventory for potential degradation mechanisms. The 3013 outer container is the boundary credited to prevent release of material to the environment. The integrity of the outer container is only at risk if the inner container loses its seal and allows corrosive gases to diffuse into the outer container. To date, the determination of potential outer container exposure to corrosive gases has been through comparison of the gas analysis of the annular space and the inner container. If the two volumes have the same gas composition and pressure, then the inner container may have leaked. The leak detection system described in this report will provide a direct measurement of the integrity of the inner container, and if approved, will provide for the elimination of gas analysis. The inner container lid leak testing system consists of two basic parts: the Agilent leak testing instrument and the leak test fixture. The test fixture base provides the connection between the leak test instrument and the test sample. This connection allows helium to flow into the leak detector when a leak path exists in the test sample allowing leak measurement to be performed. The tests reported here were conducted in a cold lab using a configuration very similar, but not identical to, the configuration anticipated when installed in a glove box. A total of sixty-five leak rate measurements were made on 10 containers and the data is included in the report. The data analysis shows that the leak detection system can identify leaks in the lid, including the weld and heat affected zone of 3013 inner containers, during destructive examination. The measurements taken support that a 3013 IC lid with a leak rate value greater than 2.0 x 10 -7 atm cc/sec will be identified using the leak test system prior to introduction into a glove box. These results from the baseline for future tests of the leak test system after it is installed in the glove box for use as part of surveillance DE.
The Packaging Surveillance Program section of the Department of Energy (DOE) Manual 441.1-1, Nuclear Material Packaging Manual (DOE 2008), requires DOE contractors to “ensure that a surveillance program is established and implemented to ensure the nuclear material storage package continues to meet its design criteria.” The Los Alamos National Laboratory (LANL) SAVY-4000 Field Surveillance Plan was first issued in fiscal year (FY) 2013 (Kelly et al. 2013). The surveillance plan is reviewed annually and updated as necessary based on SAVY-4000 surveillance findings, as well as results of the lifetime extension studies. Four surveillance plan updates have been issued, one in 2014 (Kelly et al. 2014), one in 2016 (Kelly et al. 2016), one in 2017 (Kelly et al. 2017) and one in 2018 (Kelly et al. 2018). This 2019 update documents what was actually done in 2018 and what is planned for 2019. Deviations from the 2018 surveillance plan were necessary because some of the planned surveillance containers were not available for examination.
A Surveillance Program is in place to assess how nuclear material storage containers at LANL are aging in-service. This program is guided by the LANL Surveillance Plan [1] which is required by DOE M441.1-1 requirements, and is modified as necessary to ensure that any issues identified during surveillance or laboratory studies are examined in future surveillances, and that any lifetime implications are taken into account. Under the plan, overall container integrity is evaluated (visual inspections and photographs), and helium leakage rate, O-ring durometer and compression set, and filter performance are measured. The containers for surveillance are chosen annually based on the previous surveillance program results and observations. The surveillance plan targets items believed to provide the greatest challenge to the SAVY-4000 container integrity.
The analysis described in this report shows that the measurements of Upper Assembly Outer Diameter (UAOD) and Upper Assembly Inside Height (UAIH) do not have statistically significant aging trends regardless of wattage levels. In contrast, the analysis indicates that the measurement of Air Shield Gap (ASGap) shows an increasing trend with age for high-wattage containers. However, there is considerable variability in the data. Additional older high-wattage containers need to be examined before definitive conclusions can be reached. Based on these results, future 9975 surveillance will target older high-wattage containers.
The Packaging Surveillance Program section of the Department of Energy ( DOE) Manual 441.1-1, Nuclear Material Packaging Manual (DOE 2008), requires DOE contractors to “ensure that a surveillance program is established and implemented to ensure the nuclear material storage package continues to meet its design criteria.” The Los Alamos National Laboratory (LANL) SAVY-4000 Field Surveillance Plan was first issued in fiscal year (FY) 2013 (Kelly et al. 2013). The surveillance plan is reviewed annually and updated as necessary based on SAVY-4000 surveillance findings, as well as results of the lifetime extension studies. Three surveillance plan updates have been issued, one in 2014 (Kelly et al. 2014), one in 2016 (Kelly et al. 2016) and one in 2017 ( Kelly et al. 2017). This 2018 update documents what was actually done in 2017 and what is planned for 2018. Deviations from the 2017 surveillance plan were necessary because some of the planned surveillance containers were not available for examination.