Engineering PapersSearch

Engineering topics

Keller, R. A.

Publications and source records attributed to Keller, R. A..

Computerized tomography using video recorded fluoroscopic images

The use of video-recorded fluoroscopic images as input data for digital reconstruction of objects from their projections is examined. The fluoroscopic and the scanning apparatus used for the experiments are of a commercial type already in existence in most hospitals. It is shown that for beams with divergence up to about 15 deg, one can use a convolution algorithm designed for the parallel radiation case with negligible degradation both quantitatively and from a visual quality standpoint. This convolution algorithm is computationally more efficient than either the algebraic techniques or the convolution algorithms for radially diverging data. Results from studies on Lucite phantoms and a freshly sacrificed rat are included.

Kak, A. C.

The response of fluoroscopic image intensifier-TV systems

Three different types of X-ray fluoroscopic TV chains were investigated: two standard clinical units, one with a vidicon camera tube, the other with a plumbicon camera tube; and the third was a large flat-screen unit. In each an X-ray beam generated at 100 kVp was passed through 10 cm of H2O before aluminum absorbers of varying thickness were introduced. Five video recordings were made at each absorber thickness. The video image was digitized directly from the disk recording and quantized into 128 gray levels. The five recordings were averaged on a point-to-point basis, and the central 900 averaged points were again averaged to yield a value for the gray level assigned to each particular image. This 30 by 30 matrix of points corresponds to input screen areas of 29, 8.2, and 3.6 sq cm for the three units investigated.

Baily, N. A.

A computer program for the localization of small areas in roentgenological images

A method and associated algorithm are presented which allow a simple and accurate determination to be made of the location of small symmetric areas presented in roentgenological images. The method utilizes an operator to visually spot object positions but eliminates the need for critical positioning accuracy on the operator's part. The rapidity of measurement allows results to be evaluated on-line. Parameters associated with the algorithm have been analyzed, and methods to facilitate an optimum choice for any particular experimental setup are presented.

Keller, R. A.

A physical comparison of a fluoroscopic CAT system and the EMI head scanner

A quantitative comparison of the capabilities to produce computerized tomograms was made between the EMI head scanner and reconstructions from images provided by a large screen low light level-TV camera fluoroscopic system. A phantom made from lucite containing rods of various materials and sizes was used. The computer printout of each was analyzed and a correlation of 0.8 was noted between the results of both systems. The differential attenuation detectability of the fluoroscopic system was found to be comparable to or better than the EMI unit. As expected from a consideration of the quantum statistics for each system, the noise in the obtained reconstructions was also comparable. It is concluded that such a fluoroscopic system performs favorably when compared to the presently available commercial systems.

Baily, N. A.

Simple computer method provides contours for radiological images

Computer is provided with information concerning boundaries in total image. Gradient of each point in digitized image is calculated with aid of threshold technique; then there is invoked set of algorithms designed to reduce number of gradient elements and to retain only major ones for definition of contour.

Newell, J. D.

Computerized tomography using video recorded fluoroscopic images

A computerized tomographic imaging system is examined which employs video-recorded fluoroscopic images as input data. By hooking the video recorder to a digital computer through a suitable interface, such a system permits very rapid construction of tomograms.

Kak, A. C.

A simple method for the generation of organ and vessel contours from roentgenographic or fluoroscopic images

A simple method for outlining or contouring any area defined by a change in film density or fluoroscopic screen intensity is described. The entire process, except for the positioning of an electronic window, is accomplished using a small computer having appropriate softwave. The electronic window is operator positioned over the area to be processed. The only requirement is that the window be large enough to encompass the total area to be considered.

Newell, J. D.