Engineering Papers⌕ Search

Engineering topics

Kazuhiro Sakai

Publications and source records attributed to Kazuhiro Sakai.

Line Emission Mapper Probing Physics of Cosmic Ecosystems

The Line Emission Mapper (LEM) is an X-ray Probe for the 2030s that will answer the outstanding questions of the Universe’s structure formation. It will also provide transformative new observing capabilities for every area of astrophysics, and to heliophysics and planetary physics as well. LEM’s main goal is a comprehensive look at the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. These processes are best studied in X-rays; as emphasized by the 2020 Decadal Survey, emission-line mapping is the pressing need in this area. LEM will use a large microcalorimeter array/IFU (that builds on Athena XIFU technology developments), covering a 30 × 300 field with 1000 angular resolution, to map the soft Xray line emission from objects that constitute galactic ecosystems. These include supernova remnants, star-forming regions, superbubbles, galactic outflows (such as the Fermi/eROSITA bubbles in the Milky Way and their analogs in other galaxies), the Circumgalactic Medium in the Milky Way and other galaxies, and the Intergalactic Medium at the outskirts and beyond the confines of galaxies and clusters. LEM’s 1–2 eV spectral resolution in the 0.2–2 keV band will make it possible to disentangle the faintest emission lines in those objects from the bright Milky Way foreground, providing groundbreaking measurements of the physics of these plasmas, from temperatures, densities, chemical composition to gas dynamics. While the mission is optimized to provide critical observations that will push our understanding of galaxy formation, LEM will provide transformative capability for all classes of astrophysical objects, from the Earth’s magnetosphere, planets and comets to the interstellar medium and X-ray binaries in nearby galaxies, AGN, and cooling gas in galaxy clusters. In addition to pointed observations, LEM will perform a shallow all-sky survey that will dramatically expand the discovery space.

Ralph Kraft↗

Mitigation of Finite Bandwidth Effects in Time-Division-Multiplexed SQUID Readout of TES Arrays

Time division multiplexing (TDM) is being developed as the readout technology of the X-ray integral field unit (X-IFU), a 3,168-pixel X-ray transition-edge sensor (TES) imaging spectrometer that is part of the European Space Agency's Athena satellite mission. Recent improvements in the low X-ray event count rate performance of TDM have been driven by increases in multiplexer bandwidth and the mitigation of settling transients. These methods and design changes have improved the 32-row multiplexed resolution of a NASA LPA 2.5a array from an initial (2.73 ± 0.03) eV to (1.97 ± 0.01) eV resolution at 5.9 keV. We discuss these recent advances in TDM readout, which have been implemented in an 8-column × 32-row spectrometer that will be deployed at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) facility, and present a model that will inform the design of future systems.

Transition-edge sensors↗

Calibration and Testing of Small High-Resolution Transition Edge Sensor Microcalorimeters With Optical Photons

Pulses of narrow line-width optical photons can be used to calibrate and test sub-2 eV full-width at half-maximum (FWHM) energy resolution transition-edge sensor (TES) microcalorimeters at low energies (<1 keV),where it is very challenging to obtain X-ray calibration lines comparable to (or narrower than) the detector resolution. This scheme depends on the ability to resolve the number of 3 eV photons in each pulse, which we have recently demonstrated up to photon numbers of about 300. AtLTD-18 we showed preliminary results obtained with this technique on a 0.25 eV baseline resolution TES microcalorimeter designed for the ultra-high-resolution sub-array of the Lynx mission. The line-shape was well described by a simple Gaussian. However, the difficulty of delivering photons to the small 46 μm square absorbers resulted in a large thermal crosstalk signal, whose random nature is expected to rapidly degrade the observed energy resolution towards higher photon numbers/energies. We have since improved the coupling between the optical fiber and the TES absorber and report here our current results.

Felix T Jaeckel↗

Thermal Impact of Cosmic Ray Interaction with an XRay Microcalorimeter Array

The X-ray Integral Field Unit (X-IFU) instrument on the Athena mission will be positioned at the Lagrangian point L2 and be subject to cosmic rays generated by astrophysics sources, primarily relativistic protons. Previous simulations have shown that particles of energy higher than 150 MeV will make it through the outer layers of the satellite. They will reach the detector wafer with a rate of 3 cts/sq. cm/s and a most probable energy deposited in the Si frame supporting the array at 150 keV. These events can affect the energy resolution of the detectors through the thermal fluctuations that they produce. This study assesses this potential problem and discusses two suggested design approaches to decrease the impact of cosmic ray in order to limit their effect to their allocation of 0.2 eV within the Athena/X-IFU energy-resolution budget. The first is the addition of a coating layer of high heat capacity material (e.g., Pd) and the second is the splitting of this coating into two thermal regions near the TES array to keep the heat away from the array. Implementing these two features is predicted to cause a decrease in the number of events above 1 μK by more than a factor 10 to ~ 1.5 cps when compared to an equivalent design without these features.

Antoine R. Miniussi↗

Thermal crosstalk measurements and simulations for an X-ray microcalorimeter array

Arrays of high-density microcalorimeters require careful heat sinking in order to minimize the thermal crosstalk between nearby pixels. For the array of microcalorimeters developed for the Athena X-ray Integral Field Unit instrument, which has more than 3000 pixels on a 275 µm pitch, it is essential to address this problem in order to meet the energy-resolution requirements. The instrument’s energy-resolution budget requires that the impact of the thermal crosstalk on the energy resolution be a contribution that, added in quadrature to other energy-resolution contributions, is less than 0.2 eV. This value results in a derived requirement that the ratio between the amplitude of the crosstalk signal to an X-ray pulse (for example at 6 keV) is less than 1 × 10(exp −3) (for the first neighbor), less than 4 × 10(exp −4) (for the diagonal neighbor) and less than 8 × 10(exp −5) (for the second nearest neighbor). We have measured the thermal crosstalk levels between pixels in various geometries and configurations. The results show a crosstalk ratio which is at least a factor of 4 lower than the derived requirement. We also developed a finite element (FEM) 2D thermal model to predict the thermal behavior of large-scale arrays. This model successfully simulates the measured data in terms of pulse amplitude and time constants.

Antoine R. Miniussi↗

Lynx x-ray microcalorimeter

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be a flagship mission. One of Lynx’s three instruments is an imaging spectrometer called the Lynx x-ray microcalorimeter (LXM), an x-ray microcalorimeter behind an x-ray optic with an angular resolution of 0.5 arc sec and ∼2 sq. m of area at 1 keV. The LXM will provide unparalleled diagnostics of distant extended structures and, in particular, will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the baseline design of LXM and some parallel approaches for some of the key technologies. The baseline sensor technology uses transition-edge sensors, but we also consider an alternative approach using metallic magnetic calorimeters. We discuss the requirements for the instrument, the pixel layout, and the baseline readout design, which uses microwave superconducting quantum interference devices and high-electron mobility transistor amplifiers and the cryogenic cooling requirements and strategy for meeting these requirements. For each of these technologies, we discuss the current technology readiness level and our strategy for advancing them to be ready for flight. We also describe the current system design, including the block diagram, and our estimate for the mass, power, and data rate of the instrument.

Simon R. Bandler↗

The Impact of Transition-Edge Sensor Design on Internal Thermal Fluctuation Noise and Thermal Conductance

The measured noise in transition-edge sensor (TES) microcalorimeters with a Mo/Au bilayer has been shown to have a significant contribution from internal thermal fluctuation noise (ITFN) between the absorber and the TES. Previous measurements showed the relevant thermal link leading to the noise was the thermal conductance of the TES bilayer, and ITFN has been shown to correlate with the sheet resistance of the TES. As a result, ITFN is particularly significant in devices with a large bilayer sheet resistance. However, because of more favorable transition shapes, such high resistance devices have recently been shown to be preferable under alternating current bias, which is required for the frequency division multiplexed readout baselined for the X-ray Integral Field Unit (X-IFU) instrument on the ATHENA satellite. Therefore, it is important to investigate how else to minimize the ITFN beyond changes to the sheet resistance. In this presentation, we will discuss our investigation of how changes to the TES design can affect ITFN for a fixed sheet resistance. We will present how ITFN is altered by changes to the aspect ratio of the TES, the addition of normal metal banks parallel to the TES current direction, and the size and position of the connections between the absorber and the TES. We will also discuss how these design changes impact the superconducting transition shape, and the thermal conductance from the TES to the thermal bath. These results may provide routes for further improvements of TES performance, and a deeper understanding of the physics of the thermal network in a TES microcalorimeter.

Nicholas A Wakeham↗

Performance of a broad-band, high-resolution, transition-edge sensor spectrometer for x-ray astrophysics

Future x-ray astrophysics experiments require multiplexed readout of high-fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo pixel array of Mo/Au TESs read out with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA’s Athena X-IFU, and when complete will used to laboratory astrophysics experiments. Our array and TDM readout has demonstrated a combined energy resolution, including > 200 pixels, of: 1.95 eV for Ti-K (4.5 keV), 1.97 eV for Mn-K (5.9 keV), 2.16 eV for Co-Kα (6.9 keV), 2.33 eV for Cu-Kα (8 keV), 3.26 eV for Br-Kα (11.9 keV). The 1 sigma error is  0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU.

Stephen J. Smith↗

Microcalorimeter Absorber Optimization for 0.2 to 12 keV X-Rays

The Advanced Telescope for High ENergy Astrophysics (ATHENA) mission requires high quantum efficiency (QE) x-ray absorption, >90.6% at 7 keV and low specific heat capacity, 0.731 pJ/K. The designed ATHENA x-ray absorbers are cantilevered square tiles (pitch of 317 microns) of 1.05 μm thick Au and 5.51 μm thick Bi electroplated films supported by stems that connect the absorber to the detector below. We discuss some of the methods used to produce x-ray absorbers meeting these specifications for ATHENA. To tune the thermal conductance of the device and the effect on the normal-to superconducting transition shape, the stems need to be small diameter and can have a weak bottle-neck connection to the substrate. A funnel shape of the stem using a proximity exposed photoresist mold has been developed to improve the strength of the connections. Further requirements on the absorbers include low levels of fine particulate remaining on the substrate after production and zero shorts between absorbers due to incomplete ion milling or trapped fine particular between absorbers. To optimize for post patterning substrate cleanliness and absorber yield, we have examined several methods of absorber fabrication. Three such methods are 1) an ion mill/wet etch combination, 2) a photoresist mold for electroplating followed by wet or dry etch to remove the seed layer, and 3) an electroplating process with leveling to smooth the surface followed by ion mill to separate the absorbers. The different combinations of wet and dry etches lead to different yields and surface appearance of the absorber sidewalls. We present results on the achieved pixel yields and the energy resolution of pixels made with the various fabrication methods. We discuss the impact of absorber patterning method on performance, uniformity, and yield.

Edward J Wassell↗

Towards Energy Scale Calibration and Drift Correction of TES Detectors for Athena X-IFU

The Athena X-Ray Integral Field Unit (X-IFU) comprises a 2376-pixel array of transition edge sensors (TES) read out with time-division multiplexing (TDM). X-IFU will provide spatially resolved, high-resolution spectroscopy (2.5 eV full-width-half-maximum up to 7 keV) over the energy range 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. The energy scale function maps the optimally filtered pulse height, in arbitrary engineering units, to real calibrated energy. Uncertainties in the calibration can result from imperfect fitting of the energy scale between the known calibration points. Furthermore, temporal changes in the TES operating environment, such as heat-sink temperature, magnetic field and bias voltage, can cause significant variations in the detector gain function over time. If not properly corrected, this can result in degradation of the energy resolution, and systematic errors in the absolute energy scale. The non-linear nature of TES detectors, coupled with the possibility of multiple simultaneously occurring sources of drift, can make effective corrections over the full bandpass of the instrument extremely challenging. Athena X-IFU will employ an on-board calibration source that provides known reference x-ray lines. This provides real-time monitoring of the gain stability of the detector system and information that can be used to correct for gain drifts. For X-IFU the baseline approach is to measure a series of calibration curves under different environmental conditions, which bound the expected drifts the instrument is predicted to see over the course of the mission. Using the information from the in-flight calibration source, these energy scale functions can be interpolated to generate a new corrected energy scale as a function of time. In this paper we discuss progress towards demonstrating that the X-IFU energy scale requirements can be met. We present measurements on ~ 200 pixels in a prototype X-IFU array read out with 8-column x 32-row TDM. We use a rotating target source containing 12 fluorescent targets to generate x-ray lines covering the energy range 4 keV (Sc-Kα) to 12 keV (Br-Kα). We present measurements of the non-linear energy scale function and show how variations in heat-sink temperature, TES bias voltage and magnetic field affect the shape of TES energy scale differently and introduce different residual gain errors over the bandpass. We explore different drift correction algorithms that use either a single or multiple referential lines to track and correct the gain from these various sources of drift. In addition to the pulse-height, the DC ‘baseline’ level of the TES can contain information about its bias conditions. Thus, we test a multi-parameter gain correction algorithm that attempts to incorporate both the pulse height and the additional baseline information into the algorithm.

Stephen J Smith↗

Development of a Transition-Edge Sensor Anti-Coincidence Detector for a Probe Class Mission

The Light Element Mapper (LEM), a probe class mission proposal slated for submission in 2023, combines a large X-ray optic with an extremely large format microcalorimeter array to probe the physics of galaxy formation with a grasp 22x greater than ATHENA and 7x greater than Lynx. The focal plane for LEM requires a larger anti-coincidence detector than the other missions while maintaining or exceeding their high-speed response, presenting a challenge for claiming technical readiness at the time of the announcement of opportunity (AO). We will perform a rapid demonstration in the next year including design, fabrication and integration and test of a high-fidelity transition-edge sensor (TES) based device at a scale suitable for LEM.

James Chervenak↗

New Mission Concept: Compton Telescope with Coded Aperture Mask (GECCO) for MeV Gamma-ray Astronomy

The Galactic Explorer with a Coded Aperture Mask Compton Telescope (GECCO) is a novel Explorer-class concept for a next-generation telescope covering the poorly explored hard X-ray and soft gamma-ray energy regimes. The instrument is based on a novel CdZnTe imaging calorimeter and a deployable coded aperture mask, which enable it to reach 1 arcmin angular resolution and 1% energy resolution. GECCO will connect the arcminute angular resolution observations from X-ray telescopes to high-energy images of the Galactic plane provided by Fermi-LAT, and will focus on the exploration of heavily populated sky regions such as the Galactic Center and the Carina and Cygnus regions to decipher the nature of their emission. These measurements will probe with unprecedented capabilities the possible origin of this emission as dark matter, new types of sources, or currently unresolved populations of point sources. Uncoded observations with GECCO’s Compton telescope will provide wide field-of-view sky monitoring for transient events, synergizing with gravitational wave and high-energy neutrino facilities. In addition, GECCO will conduct a high-sensitivity search for the positron sources in the Galactic Center responsible for the enigmatic 511 keV positron annihilation line excess, will search for as-yet untested candidates for dark matter, will detect and identify high-redshift blazars with excellent angular resolution, and will explore Galactic chemical evolution and sites of explosive element synthesis.

Alexander A Moiseev↗