Engineering PapersSearch

Engineering topics

Kawashima, N.

Publications and source records attributed to Kawashima, N..

At least 19 records

Space Experiments with Particle Accelerators: SEPAC

The Space Experiments with Particle Accelerators (SEPAC), which flew on the Atmospheric Laboratory for Applications and Science (ATLAS) 1 mission, used new techniques to study natural phenomena in the Earth's upper atmosphere, ionosphere and magnetosphere by introducing energetic perturbations into the system from a high power electron beam with known characteristics. Properties of auroras were studied by directing the electron beam into the upper atmosphere while making measurements of optical emissions. Studies were also performed of the critical ionization velocity phenomenon.

Burch, J. L.

Artificial auroras in the upper atmosphere. I - Electron beam injections

The Atlas-1 Spacelab payload's Space Experiments with Particle Accelerators generated artificial electron beams for the stimulation of auroral emissions at southern auroral latitudes. Optical measurements were made by the Shuttle Orbiter's onboard TV cameras, as well as by the Atmospheric Emissions Photometric Imager (in both white light and the 427.8 nm N2(+) emission line). Shuttle-based auroral imaging furnished a novel perspective on the artificial auroras; the emissions were traced from 295 km to the 110 km level along the curved magnetic-field lines.

Burch, J. L.

CIV experiments on ATLAS-1

A test of the Critical Ionization Velocity (CIV) theory was made with neutral xenon releases from the Space Experiments with Particle Accelerators hollow cathode plasma contactor onboard the Shuttle Orbiter Atlantis during the ATLAS-1 mission. The gas velocity perpendicular to the Earth's magnetic field was essentially the orbital velocity (7.5 km/s), and thus it exceeded the CIV for xenon. The releases were observed with onboard instrumentation. A factor of 60 enhancement was seen in the Langmuir probe current. Calculations confirmed that release conditions generally satisfied criteria for CIV and predicted a maximum factor of 20 increase in plasma density. Thus, CIV effects were likely to have occurred during the ATLAS-I experiments.

Marshall, J. A.

Radio science experiment of Voyager-2 spacecraft occultation by Neptune

NASA-JPL and Japan's Institute of Space and Astronautical Science collaborated at the Usuda Deep Space Center in the Voyager-2 Neptune occultation experiment. Phase information is extracted from the recorded data by means of a digital filter that can track the carrier frequency and narrow the filter bandwidth by up to 3 mHz. The results thus obtained can verify the phase-stability of the receiving system as a whole. Problems experienced by low-noise amplifiers were solved through the use of system redundancies.

Hayashi, T.

Further analysis of the results from a series of tethered rocket experiments

The data obtained in the most recent Japan-US tether rocket experiment CHARGE 2 have been further analyzed. The interaction of the moving tether system across the geomagnetic field with the ionospheric plasma can be explained by a simple model of the current through a plasma. The response of the tether system when a high voltage is applied is studied and 500 volts could be applied without any appreciable discharge. The detected signal of the wave excited by an application of high voltage between the mother and daughter rocket and by a pulse modulated electron beam is also studied.

Kawashima, N.

Results from a series of tethered rocket experiments

This paper reports the results of three tethered rocket experiments conducted as part of a U.S.-Japan joint program under way since 1980. The major purpose of the experiments is to obtain technical and scientific data supporting the figure electrodynamic tethered subsatellite experiments by the Space Shuttle. Vehicle charging due to dc beam emission up to 80 mA in the 150-200 km altitude range was repeatedly measured by both Langmuir and floating probes, and was found to be usually less than 10 V. During the 80 mA emission, clear evidence for the ignition of a beam-plasma discharge was obtained. In a tether deployment experiment, it was found that the tether wire acted as an antenna whose impedance decreased with the extension of the wire both in high-frequency and very low-frequency bands. Substantial rocket charging was observed during periods of electron-beam very low-frequency pulsing.

Sasaki, S.

Neutralization of beam-emitting spacecraft by plasma injection

An impulsive plasma injection has been used to study charge neutralization of the Space Shuttle Orbiter while it was emitting an electron beam into space. This investigation was performed by Space Experiments with Particle Accelerators on Spacelab-1. A plasma consisting of 10 to the 19th argon ion-electron pairs was injected into space for 1 ms while an electron beam was also being emitted into space. The electron beam energy and current were as high as 5 keV and 300 mA. While the orbiter potential was positive before the plasma injection and began to decrease during the plasma injection, it was near zero for 6 to 20 ms after the plasma injection. The recovery time to the initial level of charging varied from 10 to 100 ms. In a laboratory test in a large space chamber using the same flight hardware, the neutralization time was 8-17 ms and the recovery time was 11-20 ms. The long duration of the neutralization effect in space can be explained by a model of diffusion of the cold plasma which is produced near the Orbiter by charge exchange between the neutral argon atoms and the energetic argon ions during plasma injection.

Sasaki, S.

Waves generated during electron beam emissions from the Space Shuttle

Observations from the SEPAC (Space Experiments with Particle Accelerators) experiment on Spacelab 1 Shuttle mission of waves generated during electron beam emissions are presented. The dependence of the wave intensity on the beam parameters and the Shuttle attitude is outlined, and the shape of the wave spectra are discussed. It is found that the noise in the 0.75- to 10 kHz band has a spectral shape that can be characterized by an f exp -n law, and that the VLF signal level depends on the beam angle to the magnetic field, the strongest emissions being observed for parallel beams. These features are found to be consistent with a drift wave instability.

Neubert, T.

Results from a series of US/Japan tethered rocket experiments

Tethered rocket experiments have been carried out four times during a US-Japan joint space program in progress since 1980. The goal of the rocket program has been to perform a new type of active experiment by ejecting an electron beam from the tethered mother-daughter payload system. In the third and fourth rocket flights, the conductive tether wire was deployed more than 400 m. It was found that the tether wire acted as an antenna and its antenna impedance decreased with the extension of the wire both in HF and VLF bands. The vehicle charging due to the beam emission up to 80 mA was repeatedly measured in the series of the experiments. During the 80 mA emission, a clear evidence for the ignition of a beam plasma discharge was obtained by the plasma probe, photometers and wave receivers.

Sasaki, S.

Gas ionization induced by a high speed plasma injection in space

Gas ionization induced by a fast plasma injection has been observed with the Space Experiments with Particle Accelerators (SEPAC) Experiment on Spacelab-1. When an impulsive high-density plasma was injected from the orbiter, waves near the lower-hybrid frequency were enhanced, and the surrounding gas drifting with the orbiter was ionized for several tens of milliseconds after the plasma injection. The long-duration gas ionization was observed only when the plasma flux incoming to the orbiter cargo bay and the orbital velocity perpendicular to the magnetic field were relatively large. This effect has been explained by the concept of critical velocity ionization (CVI) for the gas drifting with the orbiter, although the gas velocity perpendicular to the magnetic field was less than the Alfven critical velocity.

Sasaki, S.

Ignition of beam plasma discharge in the electron beam experiment in space

An ignition of beam plasma discharge (BPD) in space was observed in a neutral gas-electron beam interaction experiment by Space Shuttle/Spacelab-1 in 1983. An electron beam of 8 kV 100 mA was injected into a high dense nitrogen gas cloud of 10 to the 23rd molecules which was released during 100 msec from the Orbiter. The appearance of the beam and its surroundings observed by a low-light-level TV camera showed a local ignition of the beam plasma discharge in the gas cloud. The enhanced plasma production, generation of auroral emission, and associated wave emission were also detected by onboard diagnostic instruments.

Sasaki, S.

Wave-particle interactions induced by SEPAC on Spacelab 1 Wave observations

Space experiments with particle accelerators (SEPAC) flew on Spacelab 1 in November and December 1983. SEPAC included an accelerator which emitted electrons into the ionospheric plasma with energies up to 5 keV and currents up to 300 mA. The SEPAC equipment also included an energetic plasma generator, a neutral gas generator, and an extensive array of diagnostics. The diagnostics included plasma wave detectors, and energetic electron analyzer, a photometer, a high sensitivity television camera, a Langmuir probe and a pressure gage. Twenty-eight experiments were performed during the mission to investigate beam-plasma interactions, electron beam dynamics, plasma beam propagation, and vehicle charging. The wave-particle interactions were monitored by the plasma wave instrumentation, by the energetic electron detector and by the optical detectors. All show evidence of wave-particle interactions, which are described in this paper.

Taylor, W. W. L.

Initial results of SEPAC scientific achievement

Electron beam injection of 5 keV, 300 mA (1.5 kW) and MPD arcjet plasma injection of 2 kJ/shot were successfully performed together with various kinds of diagnostic instruments including a high sensitivity TV camera observation in the Spacelab 1. Major scientific results obtained are studies of: (1) vehicle charge-up due to the electron beam emission and its neutralization by the MPD arcjet plasma; (2) beam-plasma interaction including the plasma wave excitation; (3) beam-atmosphere interaction such as the verification of critical velocity ionization effect; and (4) anomalous enhancement of ionization associated with a neutral gas injection into space.

Obayashi, T.

An enhancement of plasma density by neutral gas injection observed in SEPAC Spacelab-1 experiment

An enhancement of plasma density observed during a neutral gas injection in Space Experiments with Particle Accelerators by the Space Shuttle/Spacelab-1 is presented. When a plume of nitrogen gas was injected from the orbiter into space, a large amount of plasma was detected by an onboard plasma probe. The observed density often increased beyond the background plasma density and was strongly dependent on the attitude of the orbiter with respect to the velocity vector. This effect has been explained by a collisional interaction between the injected gas molecules and the ionospheric ions relatively drifting at the orbital speed.

Sasaki, S.

Space experiments with particle accelerators

Electron and plasma beams and neutral gas plumes were injected into the space environment by instruuments on Spacelab 1, and various diagnostic measurements including television camera observations were performed. The results yield information on vehicle charging and neutralization, beam-plasma interactions, and ionization enhancement by neutral beam injection.

Obayashi, T.

High time resolution measurements of rocket potential changes induced by electron beam emission

The transient charging and photon emission from the vacuum chamber testing of the Cooperative High Altitude Rocket Gun Experiment are studied. Graphs of the mother-daughter voltage versus time and high time resolution data related to the return current to the vehicle are examined. It is observed that for average sounding rocket densities of 10 to the -6th torr the slope of the voltage rise of the rocket begins to flatten 40 microsec after the onset of electron beam emission, and for higher gas pressure the rocket reaches a maximum voltage of 25 or 30 microsec after the onset of electron beam emission. The data reveal that the return current mechanism for the higher gas pressure is through the sheath.

Raitt, W. J.

Measurement of vehicle potential using a mother-daughter tethered rocket

The equipment, experimental design, and results of mother-daughter tethered probes for measuring the potential of a spacecraft are described. The object was to inject a probe into the ionosphere by rocket and then lower an impedance voltage monitor-equipped section of the probe by means of a highly insulated wire. The mother probe, also carrying voltage monitors, would inject charges into the plasma that would be measured at both ends of the tether. Instrumentation on the daughter probe included voltage current monitors and a Langmuir probe, while the mother payload also carried a charge probe, floating probe, a Langmuir probe, and an impedance probe. The first launch was from Japan in 1980, and operations confirmed that Langmuir probes with area ratios less than 400:1 can produce changes in the vehicle potential if probe voltages of more than 10 V are applied in the collection mode. A ratio of 200:1 was sufficient for the daughter probe with voltages of 5 V. The experiment is concluded to verify the tethered probe method of measuring vehicle potential.

Williamson, P. R.

Space Experiments with Particle Accelerators (SEPAC)

Plans for SEPAC, an instrument array to be used on Spacelab 1 to study vehicle charging and neutralization, beam-plasma interaction in space, beam-atmospheric interaction exciting artificial aurora and airglow, and the electromagnetic-field configuration of the magnetosphere, are presented. The hardware, consisting of electron beam accelerator, magnetoplasma arcjet, neutral-gas plume generator, power supply, diagnostic package (photometer, plasma probes, particle analyzers, and plasma-wave package), TV monitor, and control and data-management unit, is described. The individual SEPAC experiments, the typical operational sequence, and the general outline of the SEPAC follow-on mission are discussed. Some of the experiments are to be joint ventures with AEPI (INS 003) and will be monitored by low-light-level TV.

Obayashi, T.