Engineering Papers⌕ Search

Engineering topics

Kavaya, M. J.

Publications and source records attributed to Kavaya, M. J..

25 records · Page 2

Spectrophone stabilization and offset tuning of a carbon dioxide waveguide laser

A sensitive spectrophone containing CO2 gas is incorporated into a feedback loop to stabilize the frequency of a CO2 waveguide laser. First or second harmonic detection combined with a zero offset feature and the relatively high operating pressure of the laser allows continuous tuning of the stabilized frequency over a 400 MHz range. Frequency stability of better than + or - 1 MHz is achieved.

Kavaya, M. J.↗

Pulse evolution and mode selection characteristics in a TEA-CO2 laser perturbed by injection of external radiation

A grating-tunable TEA-CO2 laser with an unstable resonator cavity, modified to allow injection of CW CO2 laser radiation at the resonant transition line by means of an intracavity NaCl window, has been used to study the coupling requirements for generation of single frequency pulses. The width and shape of the mode selection region, and the dependence of the gain-switched spike buildup time and the pulse shapes on the intensity and detuning frequency of the injected radiation are reported. Comparisons of the experimental results with previously reported mode selection behavior are discussed.

Flamant, P. H.↗

Dependence of injection locking of a TEA CO2 laser on intensity of injected radiation

The results of an experimental study to determine the minimum required injected power to control the output frequency of a TEA CO2 laser are reported. A CW CO2 waveguide laser was used as the injection oscillator. Both the power and the frequency of the injected radiation were varied, while the TEA resonator cavity length was adjusted to match the frequency of the injected signal. Single-longitudinal mode (SLM) TEA laser radiation was produced for injected power levels which are several orders of magnitude below those previously reported. The ratio of SLM output power to injection power exceeded 10 to the 12th at the lowest levels of injected intensity.

Oppenheim, U. P.↗

Optogalvanic stabilization and offset tuning of a carbon dioxide waveguide laser

A feedback loop employing the change in discharge impedance with output power is used to stabilize the frequency of a CO2 waveguide laser. The relatively high operating pressure of the laser combined with a zero offset feature in the feedback loop allows continuous tuning of the stabilized frequency over a 300-400 MHz range.

Kavaya, M. J.↗

Stark effect spectrophone for continuous absorption spectra monitoring

A Stark effect spectrophone using a pulsed or continuous wave laser having a beam with one or more absorption lines of a constituent of an unknown gas is described. The laser beam is directed through windows of a closed cell while the unknown gas to be modified flows continuously through the cell between electric field plates disposed in the cell on opposite sides of the beam path through the cell. When the beam is pulsed, energy absorbed by the gas increases at each point along the beam path according to the spectral lines of the constituents of the gas for the particular field strengths at those points. The pressure measurement at each point during each pulse of energy yields a plot of absorption as a function of electric field for simultaneous detection of the gas constituents. Provision for signal averaging and modulation is included.

Kavaya, M. J.↗

Low-noise spectrophone

Spectrophone, using continuous laser beam, operates at lower noise levels and thus detects trace amounts of gases with greater sensitivity.

Kavaya, M. J.↗

Optoacoustic detection using Stark modulation

Stark modulation of the absorbed laser radiation in an optoacoustic detector (or spectrophone) is reported. Measurements were made over a range of total pressure between 760 Torr and 50 Torr. Greatly enhanced molecular discrimination is suggested due to the tuning ability of the Stark-shifted absorption. The background signal obtained by operating in this mode is more than 500 times smaller than that obtained by operating the same optoacoustic detector in the conventional chopped radiation mode. The responsivity of the optoacoustic detector and the absorption coefficient of C2H4 are presented as a function of total pressure.

Kavaya, M. J.↗