Engineering PapersSearch

Engineering topics

Kaukler, William F.

Publications and source records attributed to Kaukler, William F..

At least 19 records

System of extraction of volatiles from soil using microwave processes

A device for the extraction and collection of volatiles from soil or planetary regolith. The device utilizes core drilled holes to gain access to underlying volatiles below the surface. Microwave energy beamed into the holes penetrates through the soil or regolith to heat it, and thereby produces vapor by sublimation. The device confines and transports volatiles to a cold trap for collection.

Ethridge, Edwin C.

Metals and Oxygen Mining from Meteorites, Asteroids and Planets using Reusable Ionic Liquids

In order for humans to explore beyond Low Earth Orbit both safely and economically, it will be essential to learn how to make use of in situ materials and energy in an environment much different than on earth. Precursor robotic missions will be necessary to determine what resources will be available and to demonstrate the capabilities for their use. To that end, we have recently been studying acidic Ionic Liquid (IL) systems for use in a low temperature (< 200 C) process to solubilize regolith, and to extract, as water, the oxygen available in metal oxides. Using this method, we have solubilized lunar regolith simulant (JSC-1A), as well as extraterrestrial materials in the form of meteorites, and have extracted up to 80% of the available oxygen. Moreover, by using a hydrogen gas electrode, we have shown that the IL can be regenerated at the anode and metals (e.g. iron) can be plated onto the cathode. These results indicate that IL processing is an excellent candidate for extracting oxygen in situ, for life support and propulsion, and for extracting metals to be used as feedstock in fabrication processes. We have obtained small amounts of meteorite materials believed by meteoriticists to have originated from our moon, Mars, and the asteroid Vesta, and were able to solubilize those using acidic IL systems. From the Vesta meteorite, we were able to extract about 60% of the available oxygen as water. As far as is known, this is the first time that extraterrestrial/earth hybrid water has been obtained. NMR analysis provided proof that the liquid retrieved is indeed water. We have also been able to electro-plate nickel and iron contained in meteorite material. By varying voltage they can be plated separately (electro-winning), and we plan to soon have sufficient quantities to form usable parts utilizing the additive manufacturing process.

Karr, Laurel J.

Interaction of Porosity with a Planar Solid/Liquid Interface

In this article, an investigation of the interaction between gas porosity and a planar solid/liquid (SL) interface is reported. A two-dimensional numerical model able to accurately track sharp SL interfaces during solidification of pure metals and alloys is proposed. The finite-difference method and a rectangular undeformed grid are used for computation. The SL interface is described through the points of intersection with the grid lines. Its motion is determined by the thermal and solute gradients at each particular point. Changes of the interface temperature because of capillarity or solute redistribution as well as any perturbation of the thermal and solute field produced by the presence of non-metallic inclusions can be computed. To validate the model, the dynamics of the interaction between a gas pore and a solidification front in metal alloys was observed using a state of the art X-ray transmission microscope (XTM). The experiments included observation of the distortion of the SL interface near a pore, real-time measurements of the growth rate, and the change in shape of the porosity during interaction with the SL interface in pure Al and Al-0.25 wt pct Au alloy. In addition, porosity-induced solute segregation patterns surrounding a pore were also quantified.

Catalina, Adrian V.

Computer Simulation of the Forces Acting on the Polystyrene Probe Submerged into the Succinonitrile Near Phase Transition

Modeling approach to simulate both mesoscale and microscopic forces acting in a typical AFM experiment is presented. At mesoscale level interaction between the cantilever tip and the sample surface is primarily described by the balance of attractive Van der Waals and repulsive forces. The model of cantilever oscillations is applicable to both non-contact and "tapping" AFM. This model can be farther enhanced to describe nanoparticle manipulation by cantilever. At microscopic level tip contamination and details of tip-surface interaction can be simulated using molecular dynamics approach. Integration of mesoscale model with molecular dynamic model is discussed.

Bune, Andris V.

In-Situ X-Ray Microscopy of Phase and Composition Distributions in Metal Alloys During Solidification

This research applies a state of the art X-ray Transmission Microscope, to image the solidification of metallic or semiconductor alloys in real-time. By employing a hard x-ray source with sub-micron dimensions, resolutions of up to 3 gm can be obtained with magnifications of over 800 X. Specimen growth conditions were optimized and the best imaging technologies applied to maintain x-ray image resolution, contrast and sensitivity. In addition, a special furnace design is required to permit controlled growth conditions and still offer maximum resolution and image contrast. We have successfully imaged in real-time: interfacial morphologies, phase growth, coalescence, incorporation of phases into the growing interface, and the solute boundary layer in the liquid at the solid-liquid inter-face. We have also measured true local growth rates and can evaluate segregation structures in the solid; a form of in-situ metallography. Composition gradients within the specimen cause vafiations in absorption of the flux such that the final image represents a spatial integral of composition (or thickness). During this study, the growth of secondary phase fibers and lameilae from eutectic and monotectic alloys have been imaged during solidification, in real-time, for the first time in bulk metal alloys. Keywords: x-ray, microscope, solidification, microfocus, real-time, microstructure

Kaukler, William F.

Project Description and Publications List for UAH CMMR

This research combines a state of the art X-ray Transmission Microscope, XTM, with a specially designed x-ray transparent horizontal Bridgman furnace to image (with resolutions up to 3 micrometers) the solidification of metal alloys in real-time. The objective is to obtain real-time dynamic data to provide direct measure of the solute profile in the liquid, phase coalescence and growth in the liquid, and the detailed interface morphology (e,g., dendrites and cells) during solidification. We are also enhancing the XTM data with precise solid-liquid interfacial temperature and the thermal gradient measurement techniques, and working on the application of this technology to the study of the fundamentals of solidification in microgravity. Over the last several years we have successfully imaged in real-time: interfacial-morphologies, phase growth, coalescence, incorporation of phases into the growing interface, and the solute boundary layer in the liquid at the solid-liquid interface. We have also measured true local growth rates and can evaluate segregation structures in the solid. Interfacial undercoolings are being measured either with a special Seebeck furnace or with micro-thermocouple arrays we are developing. These later techniques are presently being incorporated with the XTM furnace. This last year emphasized the investigation of the solute layer in the melt during solidification. Methods were developed to quantify the solute concentrations using x-ray absorption and to compare to predictions from simulations. In addition, work is being completed on a brass-board portable XTM that incorporates a vertical Bridgman furnace.

Kaukler, William F.

Real-Time X-Ray Microscopy of Al-Cu Eutectic Solidification

Recent improvements in the resolution of the X-ray Transmission Microscope (XTM) for Solidification Studies provide microstructure feature detectability down to 5 micrometers during solidification. This presentation will show the recent results from observations made in real-time of the solid-liquid interfacial morphologies of the Al-CuAI2 eutectic alloy. Lamellar dimensions and spacings, transitions of morphology caused by growth rate changes, and eutectic grain structures are open to measurements. A unique vantage point viewing the face of the interface isotherm is possible for the first time with the XTM due to its infinite depth of field. A video of the solid-liquid interfaces seen in-situ and in real-time will be shown.

Kaukler, William F.

Real-Time X-Ray Transmission Microscopy for Fundamental Studies Solidification

High resolution real-time X-ray Transmission Microscopy, XTM, has been applied to obtain information fundamental to solidification of optically opaque metallic systems. We have previously reported the measurement of solute profile in the liquid, phase growth, and detailed solid-liquid interfacial morphology of aluminum based alloys with exposure times less than 2 seconds. Recent advances in XTM furnace design have provided an increase in real-time magnification (during solidification) for the XTM from 4OX to 16OX. The increased magnification has enabled for the first time the XTM imaging of real-time growth of fibers and particles with diameters of 5 micrometers. We have applied this system to study of the kinetics of formation and morphological evolution of secondary fibers and particles in Al-Bi monotectic alloys to observe a previously unreported velocity dependent thermo-capillary depletion mechanism for Bi rich liquid which can penetrate many fiber diameters into the solid-liquid interface. In this talk we will discuss application of the XTM to the study the fundamentals of monotectic and eutectic solidification, the enhancement of XTM data with precise solid liquid interfacial temperature and thermal gradient measurement techniques, and the application of this technology to the study of the fundamentals of solidification in microgravity,

Curreri, Peter A.

X-Ray Transmission Microscope Development

We have succeeded in meeting the goals set out in the proposal. A cadre of detector technologies is available to suit the requirements of the experiment. Resolutions of both real-time and absolute limits to resolution exceed the initial aspirations. Obtaining sufficient contrast is still a significant limitation but can be overcome by Judicious selection of the specimen composition. This can only take time and trial and error for a successful result. The 4th generation furnace provides the capability of real-time in-situ observations of composite alloy development. A low detection sensitivity however, has still made it difficult to observe dendritic growth, although it has been 'seen' in raw video; it was not a recordable signal. We have examined flight ampoules with XTM to observe particle and thermocouple placement, crucible flaws and cracks in collaboration with the Particle Pushing and Engulfment flight experiment (Dr. Stefanescu, UA, P.I.). The value of an in flight XTM to guard against experiment failure and safety assurance is obvious. Although not attributable to equipment limitations, a quest to observe particle pushing was not successful. We tried at length to prepare specimens that would demonstrate particle pushing. Instead, we were successful in imaging the interface deformation due to the thermal field distortion of a ceramic particle or void and to compare to calculated shapes. In theory, we should have been able to make major inroads to this field if the particles could be pushed and the velocities adjusted to make critical measurements. On the other hand, critical issues of sample preparation for the PEP flight experiment were established, particularly the clustering of particles and trapped voids. In this regard, the XTM did prove very useful so that flight specimens would work as expected and to perform post flight analysis. Although not a clear result, particle pushing of precipitates was observed in an Al-Si-Mn alloy. It may be that to be pushed, the particles need to be small and have clean surfaces like one might obtain from in-situ precipitation. The ability to image features in real time skill enable more fundamental and detailed understanding of solidification dynamics in microgravity than had previously been possible, thus, allowing the full benefits of microgravity experiments be applied towards rigorous testing of critical solidification models. The XTM is also a valuable tool for post solidification metallography. The 3-dimensional distribution of solute and solidification features within the specimen volume can be viewed without sectioning or other treatment when the solute has sufficiently higher atomic mass than the solvent. Thus the XTM could provide the first practical method for on orbit microstructural (metallographic) analysis by the astronauts or by telescience.

Kaukler, William F.

Real-Time X-Ray Transmission Microscopy of Solidifying Al-In Alloys

Real-time observations of transparent analog materials have provided insight, yet the results of these observations are not necessarily representative of opaque metallic systems. In order to study the detailed dynamics of the solidification process, we develop the technologies needed for real-time X ray microscopy of solidifying metallic systems, which has not previously been feasible with the necessary resolution, speed, and contrast. In initial studies of Al-In monotectic alloys unidirectionally solidified in an X-ray transparent furnace, in situ records of the evolution of interface morphologies, interfacial solute accumulation, and formation of the monotectic droplets were obtained for the first time: A radiomicrograph of Al-30In grown during aircraft parabolic maneuvers is presented, showing the volumetric phase distribution in this specimen. The benefits of using X-ray microscopy for postsolidification metallography include ease of specimen preparation, increased sensitivity, and three-dimensional analysis of phase distribution. Imaging of the solute boundary layer revealed that the isoconcentration lines are not parallel (as is often assumed) to the growth interface. Striations in the solidified crystal did not accurately decorate the interface position and shape. The monotectic composition alloy under some conditions grew in an uncoupled manner.

Curreri, Peter A.

Using Projection X-Ray Microscopy to Observe the Solidification Phenomena in Metals

This article outlines how projection x-ray microscopy can be used to view the structures that develop within solidifying metals during the freezing process (in real-time and in situ). A description of x-ray microscopy methods will be given. The specialized furnace design and techniques required to permit observation of solidification phenomena will also be described. Finally, a sampling of radiomicrographs taken during alloy solidification will be presented. By understanding how the microstructures in alloys form, we can improve the properties of materials (e.g. strength and corrosion resistance) or to design better materials.

Kaukler, William F.

Advancement of X-Ray Microscopy Technology and its Application to Metal Solidification Studies

The technique of x-ray projection microscopy is being used to view, in real time, the structures and dynamics of the solid-liquid interface during solidification. By employing a hard x-ray source with sub-micron dimensions, resolutions of 2 micrometers can be obtained with magnifications of over 800 X. Specimen growth conditions need to be optimized and the best imaging technologies applied to maintain x-ray image resolution, contrast and sensitivity. It turns out that no single imaging technology offers the best solution and traditional methods like radiographic film cannot be used due to specimen motion (solidification). In addition, a special furnace design is required to permit controlled growth conditions and still offer maximum resolution and image contrast.

Kaukler, William F.

Advancement of X-Ray Microscopy Technology and Its Application to Metal Solidification Studies

The technique of x-ray projection microscopy is being used to view, in real time, the structures and dynamics of the solid-liquid interface during solidification. By employing a hard x-ray source with sub-micron dimensions, resolutions of 2 microns can be obtained with magnifications of over 800 X. Specimen growth conditions need to be optimized and the best imaging technologies applied to maintain x-ray image resolution, contrast and sensitivity. It turns out that no single imaging technology offers the best solution and traditional methods like radiographic film cannot be used due to specimen motion (solidification). In addition, a special furnace design is required to permit controlled growth conditions and still offer maximum resolution and image contrast.

Kaukler, William F.

X-ray transmission microscope development

This report covers the third 6 month period, from February 28, 1995 to August 31, 1995, under this contract. The main efforts during this period were the construction of the X-ray furnace, evaluation and selection of the CCD technology for the X-ray camera, solidification experiments with Al alloys and Al-zirconia composites in the prototype furnace, evaluation of specimens for the particle pushing flight experiment - PEPSI, measurements of emitted spectra from X-ray source, testing of the high resolution X-ray test targets, and the establishment of criteria for and selection of peripheral equipment. In addition to these tasks, two presentations were prepared in this period; one for the AIAA Microgravity Symposium and another for the Gordon Conference on Gravitational Effects in Pyisico-Chemical Systems.

Kaukler, William F.

X-ray transmission microscope development

We are developing a hard x-ray microscope for direct observation of solidification dynamics in metal alloys and metal matrix composites. The Fein-Focus Inc. x-ray source was delivered in September and found to perform better than expected. Confirmed resolution of better than 2 micrometers was obtained and magnifications up to 800X were measured. Nickel beads of 30 micrometer diameter were easily detected through 6mm of aluminum. X-ray metallography was performed on several specimens showing high resolution and clear definition of 3-dimensional structures. Prototype furnace installed and tested.

Kaukler, William F.

Dynamics and statics of nonaxisymmetric and symmetric liquid bridges

This program of theoretical and experimental ground-based research focuses on the understanding of the dynamics and stability limits of nonaxisymmetric and symmetric liquid bridges. There are three basic objectives: First, to determine the stability limits of nonaxisymmetric liquid bridges held between non-coaxial parallel disks, Second, to examine the dynamics of nonaxisymmetric bridges and nonaxisymmetric oscillations of initially axisymmetric bridges. The third objective is to experimentally investigate the vibration sensitivity of liquid bridges under terrestrial and low gravity conditions. Some of these experiments will require a low gravity environment and the ground-based research will culminate in a definitive flight experiment.

Alexander, J. Iwan D.