MAGIS-100 Experiment Installation in Shaft
This poster shows the experiment and access system as it will be installed in the MINOS shaft, along with important connecting components such as the atom sources and connection nodes.
Engineering topics
Publications and source records attributed to Kasevich, Mark A..
This poster shows the experiment and access system as it will be installed in the MINOS shaft, along with important connecting components such as the atom sources and connection nodes.
Explore the source record for details and available documents.
Abstract In a uniform gravitational field, classical test objects fall universally. Any reference object or observer will fall in the same universal manner. Therefore, a uniform gravitational field cannot create dynamics between observers and classical test objects. The influence of a uniform gravitational field on matter waves and clocks, however, is described inconsistently throughout research and education. To illustrate, we discuss the behavior of a matter-wave interferometer and a clock redshift experiment in a uniform gravitational field. As a consistent formulation of the equivalence principle implies, a uniform gravitational field has no observable influence on these systems and is physically equivalent to the absence of gravity.
Experiments are beginning to probe the interaction of quantum particles with gravitational fields beyond the uniform-field regime. In nonrelativistic quantum mechanics, the gravitational field in such experiments can be written as a superposition state. We empirically demonstrate that semiclassical theories of gravity can avoid gravitational superposition states only by decoupling the gravitational field energy from the quantum particle’s time evolution. Furthermore, such theories must specify a preferred quantum reference frame in which the equations of motion are valid. To the extent that these properties are theoretically implausible, recent experiments provide indirect evidence that gravity has quantum features. Proposed experiments with superposed gravitational sources would provide even stronger evidence that gravity is nonclassical.
The robustness of an atomic fountain interferometer with respect to variations in the initial velocity of the atoms and deviations from the optimal pulse amplitude is examined. We numerically simulate the dynamics of an interferometer in momentum space with a maximum separation of and map out the expected signal contrast depending on the variance of the initial velocity distribution and the value of the laser field amplitude. We show that an excitation scheme based on rapid adiabatic passage significantly enhances the expected signal contrast, compared to the commonly used scheme consisting of a series of and pulses. We demonstrate further substantial increase of the robustness by using optimal control theory to identify splitting and swapping pulses that perform well on an ensemble average of pulse amplitudes and velocities. Our results demonstrate the ability of optimal control to significantly enhance future implementations of atomic fountain interferometry.
We present a supervised learning model to calibrate the photon collection rate during the fluorescence imaging of cold atoms. The linear regression model finds the collection rate at each location on the sensor such that the atomic population difference equals that of a highly precise optical cavity measurement. This 192 variable regression results in a measurement variance 27% smaller than our previous single variable regression calibration. The measurement variance is now in agreement with the theoretical limit due to other known noise sources. This model efficiently trains in less than a minute on a standard personal computer's CPU and requires less than 10 min of data collection. Furthermore, the model is applicable across a large change in population difference and across data collected on different days.
MAGIS-100 is a next-generation quantum sensor under construction at Fermilab that aims to explore fundamental physics with atom interferometry over a 100 m baseline. This novel detector will search for ultralight dark matter, test quantum mechanics in new regimes, and serve as a technology pathfinder for future gravitational wave detectors in a previously unexplored frequency band. It combines techniques demonstrated in state-of-the-art 10-meter-scale atom interferometers with the latest technological advances of the world’s best atomic clocks. MAGIS-100 will provide a development platform for a future kilometer-scale detector that would be sufficiently sensitive to detect gravitational waves from known sources. Here we present the science case for the MAGIS concept, review the operating principles of the detector, describe the instrument design, and study the detector systematics.
In this work, we demonstrate the utility of optical cavity generated spin-squeezed states in free space atomic fountain clocks in ensembles of 390 000 87 Rb atoms. Fluorescence imaging, correlated to an initial quantum nondemolition measurement, is used for population spectroscopy after the atoms are released from a confining lattice. For a free fall time of 4 milliseconds, we resolve a single-shot phase sensitivity of 814(61) microradians, which is 5.8(0.6) decibels (dB) below the quantum projection limit. We observe that this squeezing is preserved as the cloud expands to a roughly 200 μ m radius and falls roughly 300 μm in free space. Ramsey spectroscopy with 240 000 atoms at a 3.6 ms Ramsey time results in a single-shot fractional frequency stability of 8.4(0.2) × 10 –12 , 3.8(0.2) dB below the quantum projection limit. The sensitivity and stability are limited by the technical noise in the fluorescence detection protocol and the microwave system, respectively.
This report presents the results of the 2012-2013 NASA Institute for Advanced Concepts (NIAC) Phase 1 "Atom Interferometry for Detection of Gravitational Waves" project. The origin of this GW (Gravitational Wave) detection concept using atoms can be traced to theoretical work that first appeared in 2008 and also to a satellite mission-focused followup study that was done in 2011. The goal of the current project was to explore both theoretical and technical issues surrounding the implementation of this idea, as well as to begin performing proof-of-concept experiments to validate critical aspects of the proposal.The top level trade space for the detector design is driven by the strategy employed to mitigate laser frequency noise, which, if uncontrolled, can mask GW signatures. One of the advantages of the atom interferometric approach is the possibility of single baseline detection (Fig. 1.1), even in the presence of laser noise. This is enabled by the differential measurement between the two ensembles of atoms, which can result in substantial laser noise suppression. The details of this suppression depend on the atomic physics techniques used to implement the atom interferometry. Specifically, we considered the effect on noise suppression that results from using traditional two-photon Raman transitions (with alkali atoms) and also single-photon transitions (with alkaline earth-like atoms).The interferometers shown in Fig 1.1(b) take advantage of single-photon transitions (as opposed to traditional Raman transitions) because using light pulses from one direction at a time allows for near perfect common-mode cancellation of laser phase noise, even for long baselines. This calls for the use of atomic transitions with an (ideally large) optical energy level difference with a long (greater than 1 second) lifetime, such as high-transitions routinely used for optical atomic clocks in species like Sr, Ca and Yb. Notably, large momentum transfer (LMT) atom optics - and the sensitivity enhancement they confer – can still be realized by simply adding additional pairs of alternating pulses to each beam splitter process. Section 3 reports on the theoretical work we performed to justify this GW detection protocol using single-photon transitions. This approach represents a new method for GW detection using atoms that is distinct from the original proposal from 2008. At the system level, we evaluated three architectures, each of which implements a different solution to the laser frequency noise issue. The first two designs are based on two-photon Raman transitions with Rb atoms. One of these is a three-satellite, multiple baseline design while the other is a two-satellite, single baseline design. The third proposal is a two-satellite, single baseline design that uses single-photon transitions with Sr atoms. These three architectures are described in more detail in Section 2. There are a number of known technical issues that we have started to address using ground-based experiments. These issues include atom technology development needs such as, for example, lower ensemble temperature requirements and large momentum transfer (LMT) atom optics. To this end, we have built a 10-meter scale atom drop tower, where we can perform proof-of-principle demonstrations of the proposed AGIS detector in an environment that permits more than 2.5 seconds of free-fall time. This facility allows for demonstration of atom interferometry with long interrogation time (seconds) and large atom wavepacket