Engineering Papers⌕ Search

Engineering topics

Kaneko, M.

Publications and source records attributed to Kaneko, M..

Constraining nucleon effective masses with flow and stopping observables from the S π RIT experiment

Properties of the nuclear equation of state (EoS) can be probed by measuring the dynamical properties of nucleus-nucleus collisions. In this study, we present the directed flow (υ 1 ), elliptic flow (υ 2 ) and stopping (VarXZ) measured in fixed target Sn + Sn collisions at 270 AMeV with the SπRIT Time Projection Chamber. We perform Bayesian analyses in which EoS parameters are varied simultaneously within the Improved Quantum Molecular Dynamics-Skyrme (ImQMD-Sky) transport code to obtain a multivariate correlated constraint. The varied parameters include symmetry energy, S 0 , and slope of the symmetry energy, L, at saturation density, isoscalar effective mass, $m^{⁎}_{S}$/$m_{N}$ , isovector effective mass, $m^{⁎}_{υ}$/$m_{N}$ and the in-medium cross-section enhancement factor η. We find that the flow and VarXZ observables are sensitive to the splitting of proton and neutron effective masses and the in-medium cross-section. Comparisons of ImQMD-Sky predictions to the SπRIT data suggest a narrow range of preferred values for $m^{⁎}_{S}$/$m_{N}$, $m^{⁎}_{υ}$/$m_{N}$ and η.

Astronomy & Astrophysics↗

Multiplicity trigger detector for the S π RIT experiment

A multiplicity trigger detector (MTD) was developed for the SπRIT experiment that aims to probe the high- density symmetry energy via heavy-ion collisions (HICs). The MTD is designed to measure the charged-particle multiplicity in HICs to provide a trigger signal that can be used to select high-multiplicity events induced by central collisions. The MTD consists of two side-walls segmented into 30 plastic scintillation paddles, each equipped with a multi-pixel photon counter. A custom board with EASIROC front-end ASIC is used as readout electronics. A multiplicity logic signal is generated by an on-board FPGA that processes the discriminated signals from EASIROCs. The overall latency of the whole detector system for outputting the trigger is less than 100 ns, including 52 ns of electronics latency for processing the signals. During the measurement of 112 Sn + 124 Sn reactions at an incident energy of 270 MeV/nucleon, the minimum multiplicity threshold of the MTD was set to 4, where the overall trigger efficiency was obtained to be about 39 % for inclusive nuclear reactions. Furthermore, a simulation study with a numerical calculation of HICs found that the central collisions of impact parameters of less than 4 fm can be triggered with a high efficiency of more than 95 % by the experimental trigger condition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vuilleumier cycle cryocooler operating below 8 K

This paper describes the design and development of a Vuilleumier cycle cryocooler (VM cooler) operating below 8 K, for the application of small superconducting devices. Liquid nitrogen has been used as a heat sink of the hot displacer. The annular gap between the phenolic displacer and SUS 304 stainless cylinder has been used as a gap regenerator. In order to obtain the cooling temperature below 3 K, we designed a single stage VM cooler which is precooled to 10 K by another two stage VM cooler. The effect of the mean operating pressure, cycle speed and phase difference between the hot and cold displacer of each VM cooler will be also discussed, including the experimental results.

Matsubara, Y.↗

Compact Claude cycle refrigerator for laboratory use

A Claude cycle refrigerator with a three stage reciprocating expansion engine is described. Instead of a cam mechanism, valves are driven directly by magnetic solenoids operated by means of a micro processor control system. A swash plate mechanism is used to convert reciprocating motion of the expander pistons to rotary motion. A refrigeration capacity of 8 watts was achieved at 4.5 K with the operating pressure of 1.1 MPa and flow rate of 2.4 g/sec.. An effect of overintake operation was studied. Experimental results show that the efficiency of the expander has a peak point in the region of overintake operation with constant cycle speed, which agrees with theoretical results. The electrically controlled valve system is useful to vary the valve timing to achieve an optimum condition of operation.

Hiersaki, Y.↗

Muscle training and blood flow

Isotonic training effects on circulation for limb muscular strength characteristics, using peak blood flow and venous compliance measurements

Carlson, L. D.↗