Engineering PapersSearch

Engineering topics

Kaiser, W. J.

Publications and source records attributed to Kaiser, W. J..

At least 19 records

Micro Inertial Reference System for Microspacecraft

This paper reports on the development of a silicon bulk micromachined vibratory gyroscope designed for a micro inertial reference system for microspacecraft applications.

Micro inertial reference system microspacecraft si

A Packaged Silicon MEMS Vibratory Gyroscope for Microspacecraft

In this paper, we present recent work on the design, fabrication, and packaging of a silicon MIcro-Electro-Mechanical System (MEMS) microgyroscope designed for space applications. A hermetically sealed package that houses the microgyroscope and most of its control electronics has been built and tested.

MEMS micro-electromechanical system microspacecraf

Silicon Bulk Micromachined Vibratory Gyroscope

This paper reports on design, modeling, fabrication, and characterization of a novel silicon bulk micromachined vibratory rate gyroscope designed for microspacecraft applications. The new microgyroscope consists of a silicon four leaf cloverstructure with a post attached to the center.

gyroscope microgyroscope

Measurements of Local Strain Variation in Si(1-x)Ge(x)/Si Heterostructures

The energy splitting of the conduction-band minimum of Si(1-x), Ge(x), due to strain has been directly measured by the application of ballistic-electron-emission microscope (BEEM) spectroscopy to Ag/Si(1-x), Ge(x) structures. Experimental values for this conduction-band splitting agree well with calculations. For Au/Si(1-x), Ge(x), however, heterogeneity in the strain of the Si(1-x), Ge(x) layer is introduced by deposition of the Au. This variation is attributed to species interdiffusion, which produces a rough Si(1-x)Ge(x) surface. Preliminary modeling indicates that the observed roughness is consistent with the strain variation measured by BEEM.

Bell, L. D.

Ballistic-Electron-Emission-Microscopy of Strained Si(sub 1-x)Ge(sub x) Layers

Ballistic-electron-emission microscopy (BEEM) has been used to investigate the effects of strain on Si(sub 1-x)Ge(sub x) alloys. Lifting of the degeneracy of the conduction-band minimum of Si(sub 1-x)Ge(sub x), due to lattice deformation has been directly measured by application of BEEM spectroscopy to Ag/Si structures. Experimental values for this conduction-band splitting agree well with calculations. In addition, an unexpected heterogeneity in the strain of the Si(sub 1-x)Ge(sub x) layer is introduced by deposition of Au. This effect, not observed with Ag, is attributed to species interdiffusion and has important implications for metal-semiconductor devices based oil pseudomorphic Si(sub 1-x)Ge(sub x)/Si material systems.

Bell, L. D.

Capacitive Edge Sensor Design for Selene Segmented Primary Mirror

The objective of this project is to produce a proof-of-concept demonstration of an edge sensor for the Space Laser Energy (SELENE) program. In the SELENE telescope, the primary mirror design sonsists of more than 200,000 segments which must be precisely aligned to correct for distortions in the optical train

SELENE

Ballistic-Electron-Emission Microscopy of Strained Si l-x Ge x Layers

Ballistic-electron-emission microscopy has been used to investigate the effects of strain on Si l-x Ge x alloys. Lifting of the degeneracy of the conduction-band minimum of SiGe due to lattice deformation has been directly measured by application of BEEM spectroscopy to Ag/Si structures.

lattice

Beem Spectroscopy of Electron Transport Through A1As/GaAs Heterostructures

BEEM spectroscopy has been used to characterize hot carrier transport through A1As/GaAsheterostructures. The dependence of electron transmission on A1As thickness has been directlymeasured, and the position of the A1As L_1 minima, which has been subject to some uncertainty inthe past, has been determined. First-principles transmission calculations, based on a tight-bindingformalism, are compared to the results of BEEM spectroscopy.

Kaiser, W. J.

Microinstruments for a Low Power, Low Mass Weather Station

Advances in electronics and instrument technology over the past thirty years have enabled a new concept for NASA missions, an evolution from large Voyager-class spacecraft to smaller, less costly Discovery and Explorer missions. By taking advantage of micromachining and micro-instrumentation, this reduction in size can be accomplished without requiring a sacrifice in performance. In some cases, the small payload will enable new types of missions which would be otherwise inconceivable. A microweather station is envisioned as an enabling technology for a network of weather stations on Mars for measuring wind, temperature, pressure, humidity, and aerosol concentration in the Martian planetary boundary layer...

Hoenk, M. E.

Ballistic Electron Emission Microscopy of Metal/Group IV Interfaces

Ballistic electron emission microscopy and spectroscopy, together with related techniques, have been applied with great success to the study of buried interfaces. These probes, known collectively as BEEM, have yielded important information on interface transport, interface band structure, and carrier scattering, with lateral spatial resolution on the nanometer scale. Recent applications of the technique to polycrystalline metal/semiconductor interfaces have demonstrated an ability to spatially map both conduction band and valence band semiconductor structure. BEEM studies of epitaxial silicide/silicon interfaces have been particularly fruitful, as the rich silicide band structure results in complex and often surprising transport behavior...

Hecht, M. H.

A broad-band microseismometer for planetary operations

There has recently been renewed interest in the development of instrumentation for making measurements on the surface of Mars. This is due to the Mars Environmental Survey (MESUR) Mission, for which approximately 16 small, long-lived (2-10 years), relatively inexpensive surface stations will be deployed in a planet-wide network. This will allow the investigation of processes (such as seismology and meteorology) which require the simultaneous measurement of phenomena at many widely spaced locations on the surface over a considerable length of time. Due to the large number of vehicles involved, the mass, power, and cost of the payload will be severely constrained. A seismometer has been identified as one of the highest priority instruments in the MESUR straw-man payload. The requirements for an effective seismic experiment on Mars place a number of constraints on any viable sensor design. First, a large number of sensors must be deployed in a long-lived global network in order to be able to locate many events reliably, provide good spatial sampling of the interior, and increase the probability of seismic detection in the event of localized seismicity and/or high attenuation. From a practical standpoint, this means that individual surface stations will necessarily be constrained in terms of cost, mass, and power. Landing and thermal control systems will probably be simple, in order to minimize cost, resulting in large impact accelerations and wide daily and seasonal thermal swings. The level of seismic noise will determine the maximum usable sensitivity for seismometer. Unfortunately, the ambient seismic noise level for Mars is not well known. However lunar seismic noise levels are several orders of magnitude below that of the Earth. Sensitivities on the order of 10(exp -11)g over a bandwidth of .04 to 20 Hz are thought to be necessary to fulfill the science objectives for a seimometer placed on the Martian surface. Silicon micromachined sensor technology offers techniques for the fabrication of monolithic, robust, compact, lower power and mass accelerometers. Conventional micro-machined accelerometers have been developed and are commercially available for high frequency and large acceleration measurements. The new seismometer we are developing incorporates certain principles of conventional silicon micromachined accelerometer technology. However, currently available silicon micromachined sensors offer inadequate sensitivity and bandwidth for the Mars seismometer application. Our implementation of an advanced silicon micromachined seismometer is based on principles recently developed at JPL for high-sensitivity position sensor technology.

Banerdt, W. B.

Micromachined electron tunneling infrared sensors

The development of an improved Golay cell is reported. This new sensor is constructed entirely from micromachined silicon components. A silicon oxynitride (SiO(x)N(y)) membrane is deflected by the thermal expansion of a small volume of trapped gas. To detect the motion of the membrane, an electron tunneling transducer is used. This sensor detects electrons which tunnel through the classically forbidden barrier between a tip and a surface; the electron current is exponentially dependent on the separation between the tip and the surface. The sensitivity of tunneling transducers constructed was typically better than 10(exp -3) A/square root of Hz. Through use of the electron tunneling transducer, the scaling laws which have prevented the miniaturization of the Golay cell are avoided. This detector potentially offers low cost fabrication, compatibility with silicon readout electronics, and operation without cooling. Most importantly, this detector may offer better sensitivity than any other uncooled infrared sensor, with the exception of the original Golay cell.

Kenny, T. W.

Ballistic-Electron-Emission Microscopy Techniques for Nanometer-scale Characterization of Interfaces

Semiconductor interface properties are among the most important phenomena in materials science and technology. The study of metal/semiconductor Schottky barrier interfaces has been the primary focus of a large research and development community for decades. Throughout the long history of interface investigation, the study of interface defect electronic properties have been seriously hindered by the fundamental experimental difficulty of probing subsurface structures. A new method, Ballistic-Electron-Emission Microscopy (BEEM), has been developed which not only enables spectroscopic probing of subsurface interface properties, but also, provides nanometer-resolution imaging capabilities. BEEM employs Scanning Tunneling Microscopy (STM) and a unique spatially localized ballistic electron spectroscopy method...

Bell, L. D.

Micromachined Tunneling Displacement Transducers for Physical Sensors

We have designed and constructed a series of tunneling sensors which take advantage of the extreme position sensitivity of electron tunneling. In these sensors, a tunneling displacement transducer, based on scanning tunneling microscopy principles, is used to detect the signal-induced motion of a sensor element. Through the use of high-resonant frequency mechanical elements for the transducer, sensors may be constructed which offer wide bandwidth, and are robust and easily operated. Silicon micromachining may be used to fabricate the transducer elements, allowing integration of sensor and control electronics. Examples of tunneling accelerometers and infrared detectors will be discussed. In each case, the use of the tunneling transducer allows miniaturization of the sensor as well as enhancement of the sensor performance.

Kenny, T. W.