Engineering Papers⌕ Search

Engineering topics

Kahn, S. M.

Publications and source records attributed to Kahn, S. M..

54 records · Page 3

Einstein Observations of the Cygnus Loop

The imaging instruments on the Einstein Observatory were used to study the detailed X-ray structure of the Cygnus Loop. An arc minute resolution map of the 0.1-4.0 keV emission from the entire remnant was obtained with the imaging proportional counter (IPC). The bright northeastern and western limbs were mapped with the high resolution imager (HRI). The large-scale structure of the Loop is well modeled as a limb-brightened shell of hot gas at 2 x 10 to the 6th K created by the expansion of a blast wave into an inhomogeneous interstellar medium. The pulse-height data from the IPC indicate that the center of the remnant is generally hotter than the limb with temperatures as high as 4 x 10 to the 6th K. The X-ray maps show good general correlation with large-scale radio and optical structure, and in some cases good detailed correlation with faint optical filaments dominated by hydrogen line emission.

Ku, W. H.-M.↗

Observations of quasi-coherent soft X-ray oscillations in U Geminorum and SS Cygni

During the HEAO 1 satellite's detection of soft X-ray pulsations from U Geminorum and SS Cygni, both of these dwarf novae were on the declining phase of an optical outburst. The pulsations are quasi-coherent in character, with average pulse amplitudes of 15 percent for U Gem and 18 percent for SS Cyg. From pulse phase X-ray spectroscopic data, an upper limit of 50 percent may be set on any variation in temperature across U Gem's pulse. Attention is given to all data on the X-ray and optical pulsations thus far detected in these two novae, and the observational constraints on the various current models for the pulsations are discussed.

Cordova, F. A.↗

Photospheric soft X-ray emission from hot DA white dwarfs

The Einstein Observatory's imaging proportional counter has detected 150-eV soft X-ray radiation from the four hot DA white dwarfs EG 187, Gr 288 and 289, and LB 1663. The observed pulse height spectra suggest that the emission is generated by hot photospheres whose T(eff) lie in the 30,000-60,000 K range. The IUE spacecraft UV spectra and H-beta line profiles for the four stars have been fitted, along with the X-ray fluxes, with a grid of hot, high gravity, homogeneous model atmospheres of mixed H-He composition. In all cases, the data require the presence of some X-ray opacity in the photosphere. Attention is given to the implications of this result in the context of white dwarf surface layer diffusion theories. Also noted are the limits imposed on the hot white dwarf population by the Einstein Medium Sensitivity Survey.

Wesemael, F.↗

An X-ray study of the remnant of SN 185 A.D.

High-resolution X-ray maps obtained with the Einstein Observatory of the supernova remnant RCW 86 are presented. Analysis of the spatial and spectral properties of the remnant yield a total X-ray emitting mass of not greater than about 5 solar masses and a surrounding mean interstellar density of about 0.3/cu cm. A revision of the generally accepted distance of 2.5 kpc downward to not greater than about 1 kpc is strongly suggested by the data. The diameter (about 13 pc) and X-ray plasma temperature (about 1 keV) are consistent with the identification of the remnant with the supernova of 185 A.D. The observed apparent magnitude of SN 185 coupled with the new distance, the implied explosion energy and ejected mass derived from a Sedov analysis, and the lack of any compact remnant are all characteristic of a Type I event.

Pisarski, R. L.↗

X-ray observations of LMC X-3 with the monitor proportional counter aboard the HEAO 2 Einstein observatory - A comparison with Cygnus X-1

A comparison is presented of the black hole candidates LMC X-3 and Cygnus X-1 based on Einstein observations of LMC X-3 with the monitor proportional counter. A spectral analysis shows LMC X-3 to be more like the typical bright galactic X-ray source than Cygnus X-1. A search for periodic pulsations over a period range from 0.2 ms to over 1000 s set upper limits at the 90 percent confidence level of the order of 10 percent. An analysis of the aperiodic variability of LMC X-3 shows none of the shot noise behavior characteristic of Cygnus X-1. The absence of distinctive X-ray properties common to both sources suggests that the identification of black hole candidates on the basis of X-ray properties similar to Cygnus X-1 (or LMC X-3) is not reliable.

Weisskopf, M. C.↗

The soft X-ray spectrum of the Vela supernova remnant

An X-ray spectrum of a major fraction of the Vela supernova remnant has been obtained during scanning observations with the low energy proportional counters of the A-2 experiment, flown on HEAO 1. A deconvolution analysis of the data shows that the spectrum exhibits pronounced line emission near 0.6 keV due primarily to oxygen ions. Model fits using the Raymond-Smith hot plasma emission calculations indicate that the spectrum can be well described by a model involving two collisional equilibrium components with temperatures of 2.4 x 10 to the 6th and 1.9 x 10 to the 7th K, respectively. The abundances of oxygen and iron are found to be constrained to lie near their normal cosmic values.

Kahn, S. M.↗

X-ray observations of 4U 1626-67 by the monitor counter on the Einstein /HEAO 2/ observatory

The pulsing X-ray source 4U 1626-67 was observed with the Monitor Proportional Counter (MPC) on board the Einstein X-Ray Observatory on three occasions in early 1979. The MPC is a sealed, argon-filled proportional counter with a 1.5 mil beryllium window and is coaligned with the X-ray telescope on board the observatory. The spectral data spanning the energy range from 1.1 to 21 keV are divided into eight logarithmically spaced energy channels which integrate for 2.56 s. The Time Interval Processor (TIP) circuitry of the MPC measures time intervals between events to within 1 microsecond or 1.6%, whichever is larger, for a count rate dependent fraction of all events in all eight energy channels. It is found that in the energy range from 1 to 21 keV, the spectrum and 7.7 s pulse shape of 4U 1626-67 are variable on a time scale of minutes. The pulse shape variations correlate in a complex way with the intensity variations in this source.

Elsner, R. F.↗

The soft X-ray spectrum of Sirius B - Evidence for the photospheric hypothesis

The soft X-ray spectrum of Sirius obtained by the HEAO 1 A-2 experiment is used to investigate the origin of the X-radiation from that system. It is shown that, if the emission is coronal, then the coronal temperature must be less than 150,000 K, and the coronal luminosity must be greater than 10 to the 33rd ergs/s. Such a corona conflicts severely with EUV observations and is physically untenable. White dwarf atmosphere models are fitted to the spectrum and it is shown that a photospheric temperature of 28,000 K is much more consistent with the data. The relative consistency of the soft X-ray, EUV, and UV observations of Sirius B is discussed and it is concluded that the evidence favors the white dwarf photosphere as the origin of the soft X-rays.

Martin, C.↗

Soft X-ray spectral variations in Scorpius X-1

Soft X-ray spectra of Scorpius X-1 obtained with the low-energy detectors of the A-2 experiment on HEAO 1 are presented. The raw count spectra are deconvolved using the Kahn and Blissett technique to reveal the presence of oxygen absorption in the range 0.5-0.7 keV. The strength of this feature is shown to vary on a time scale of order hours. These results are interpreted as evidence for variable X-ray photoionization of circumsource material in the system. An alternative model, involving variable Compton broadening of an oxygen edge, is also discussed.

Kahn, S. M.↗

Low-energy X-ray line emission from IC 443

HEAO 1 observations of the spectrum of the supernova remnant IC 443 in the energy range of 0.4-3 keV reveal the presence of a complex structure suggestive of emission from Fe XVIII-XX, S XV-XVI, and Si XIII-XIV ions. The best electron temperature in the band for simple model fits is about (6-11) x 10 to the 6th K. Raymond and Smith collisional equilibrium emission models do not adequately fit the data. These results are discussed in terms of possible nonequilibrium effects in the remnant.

Charles, P. A.↗

X-ray line emission from the Cygnus Loop

The HEAO 1 satellite has observed the X-ray spectrum of the Cygnus Loop in the 0.1-2.0 keV band. The observed count-rate spectrum is deconvolved by the Kahn and Blissett technique to demonstrate conclusively the presence of oxygen- and iron-line emission between 0.6 and 0.9 keV. The spectrum has been fitted with single- and two-component Raymond-Smith plasma emission models. The best-fit dominant X-ray temperature is approximately 3,200,000 K, and the best-fit interstellar column density is approximately a few times 10 to the 20th/sq cm.

Kahn, S. M.↗

The direct deconvolution of X-ray spectra

The method of deconvolution of proportional counter X-ray spectra as outlined by Blissett and Cruise is reviewed with particular emphasis on low-energy spectra. This method involves the expansion of the incident spectrum in terms of a set of orthonormal singular functions which propagate independently through the detector matrix. When applied to low-energy detectors which typically exhibit absorption features in their efficiency curves, the initial Blissett and Cruise prescription is shown to be unstable. Alternative methods for handling the efficiency are described and evaluated. In the deconvolution of steep spectra, additional distortions are shown to arise as a result of sidelobe oscillations in the effective response functions. A selective weighting procedure is thus introduced to suppress spurious features of this type. Finally, the role of filtering in the deconvolution procedure is discussed and several suitable forms for the filter are suggested.

Kahn, S. M.↗

HEAO 1 observations of X-ray emission from flares on dMe stars

The paper reports the detection of two X-ray flares from each of the nearby dMe stars, AT Mic and AD Leo, with the A-2 experiment on board HEAO 1. A spectrum obtained during the brighter AT Mic flare, the first X-ray spectrum of a stellar flare, is well matched by a thermal model with a temperature 3 x 10 to the 7 K and an iron K-alpha emission line. The X-ray luminosities derived are in the range 1.3-16 x 10 to the 30th ergs/s, while emission measures are in the range 1.1-14 x 10 to the 53rd/cu cm. The estimated Lx/Lopt ratios exceed unity and are inconsistent with Mullan's flare model. Several scenarios to explain this discrepancy are proposed.

Kahn, S. M.↗

Soft X-ray emission from the vicinity of MV Lyr

Evidence for a soft X-ray source at the location of the nova-like variable star MV Lyr is presented. Data from the smallest field of view of the A2 experiment on board HEAO-1 in the range 0.18 to 2.5 keV reveals a source of 0.18 to 0.43 keV emission, designated H1901+43, with a count rate corresponding to a flux of 4 x 10 to the -12th erg/sq cm per sec if a spectral temperature of 3 x 10 to the 5th K is assumed. The two-dimensional error box of H1901+43 is observed to contain the UX UMa star MV Lyr, which is suggested as the only obvious candidate for the source of X-ray emission, in accordance with the observations of soft X-ray emission from other cataclysmic variables, notably AM Her, U Gem and SS Cyg.

Mason, K. O.↗

Soft X-ray spectrum and structure of the supernova remnant G65.2+5.7

The HEAO 1 low energy detectors have observed the supernova remnant G65.2+5.7 in the energy range 0.2-2.5 keV. A strong, extended source of X-ray emission is observed coincident with the eastern side of the optical filamentary structure. The characteristic temperature of the emission is in the range 2-3.8 x 10 to the 6th K, and evidence is found for line emission at about 0.8 keV in the X-ray spectrum. These observations imply a shock velocity (425 km/s) and age (about 20,000 yr) that markedly disagree with the estimates from optical and radio observations.

Mason, K. O.↗

The interstellar oxygen edge in the X-ray spectrum of the Crab Nebula

Measurement of the X-ray spectrum of the Crab Nebula by the HEAO 1 A-2 low-energy (0.15-3 keV) detectors is reported. The spectral restoration techniques described by Blissett and Cruise (1979) and Kahn and Blissett (1979) are used to demonstrate explicitly the existence of a 'negative' feature near 0.5 keV that is consistent with the edge expected due to absorption by interstellar oxygen. For a simple power-law model with photon index -2.08, the data require a column density of 3.0 + or - 0.1 x 10 to the 21st per sq cm and an oxygen abundance of 1.0 + or - 0.1 times the Brown and Gould (1970) value. Satisfactory fits can also be achieved with the more sophisticated Fireman (1974) models, but no model can be adjusted to fit the data without the inclusion of interstellar oxygen.

Charles, P. A.↗

Short-term time variability of Cygnus X-1. II

A complete theory for shot-noise analysis is presented. The theory takes into account the effects of counting statistics, time resolution, and finite observing times on the autocorrelation function and on the moments of data assumed to consist of shot noise plus a steady component. When applied to X-ray observations of Cyg X-1 in the high and low states, the results provide evidence that both the typical correlation time (about 0.5 s) and the fraction of flux in shots (about 30%) are constant, independent of the state. The rate of occurrence of the shots may also be constant at approximately one shot per second, a possibility which, if verified, would imply that the principal difference in time variability in the two states is the amplitude of the shots. We also suggest that the occasionally observed large flares may possibly be just the rare superposition of several shots.

Sutherland, P. G.↗

Short-term time variability of Cygnus X-1

Autocorrelation functions, power-density spectra, and cross-correlation functions were calculated for 71 observations of Cyg X-1 by the Uhuru satellite. The average autocorrelation function and power-density spectrum were found to be independent of energy and consistent with a shot-noise source with a characteristic time constant of 0.45 s. The data in different energy bands were found to be 100 percent correlated.

Weisskopf, M. C.↗