Engineering Papers⌕ Search

Engineering topics

K Nakamura-Messenger

Publications and source records attributed to K Nakamura-Messenger.

The Comet Astrobiology Exploration Sample Return (CAESAR) Mission

The Comet Astrobiology Exploration Sample Return (CAESAR) mission will acquire and return to Earth for laboratory analysis a minimum of 80 grams of surface material from the nucleus of comet 67P/Chur-yumov-Gerasimenko (67P). CAESAR will characterize the surface region sampled, preserve the collected sample in a pristine state, and return evolved volatiles by capturing them in a separate gas reservoir. NASA Goddard Space Flight Center provides project management, systems engineering, safety and mission assurance, contamination control, mission operations, and many other important functions. Northrop Grumman Space Systems will build the spacecraft, based on Dawn mission heritage, which like CAESAR, uses solar electric propulsion. CAESAR was selected by for Phase A study in the New Frontiers 4 Competition and will be proposed to New Frontiers 5.Collection of a sample from the surface of comet 67P is facilitated by a set of cameras that together provide images to support sample site selection, perform optical navigation, and document the sample before, during, and after col-lection. The sample is collected at the end of an arm during a 5-second touch-and-go (TAG) maneuver with the Sample Acquisition System (SAS)designed by Honeybee Robotics for the surface properties of comet 67P observed by the Rosetta mission. After sample collection, and while the sample is still cold (< -80°C), the TAG Arm inserts the sample container into the Sample Containment System (SCS) mounted inside the Sample Return Capsule (SRC). The SCS is sealed, preventing the sample from escaping into space. The sample is slowly warmed inside the SCS to enable sublimation of volatiles, which are collected in the Gas Containment System (GCS), a passively cooled gas reservoir. Separating the volatiles from the solid sample protects the solid sample from alteration. Once all sublimated H2O is transferred to the GCS, the GCS is sealed to capture the volatile sit contains, and the SCS is vented to space to maintain the solid sample under vacuum. The SCS vent is closed before Earth entry to prevent atmospheric contamination. Detailed laboratory analyses of the sample from 67P will trace the history of volatile reservoirs, delineate the chemical pathways that led from simple interstellar species to complex molecules, constrain the evolution of the comet, and evaluate the role of comets in delivering water and prebiotic organics to the early Earth. CAESAR will achieve these goals by carrying out coordinated sample analyses that will link macroscopic properties of the comet with microscale mineralogy, chemistry, and isotopic studies of volatiles and solids. Most of the sample (≥75%) will be set aside for analyses by generations of scientists using continually advancing tools and methods, yielding an enduring scientific treasure that only sample return can provide. This presentation will review development conducted during NF4 Phase A and discuss the NF5 mission concept.

A G Hayes↗

Microbial Monitoring of New Cleanrooms Used to Curate Astrobiologically Relevant Asteroid Samples from Bennu and Ryugu

Introduction: NASA has constructed two new cleanrooms to house materials from the OSRIS-REx and Hayabusa2 missions to the asteroids Ryugu (162173) and Bennu (101955), respectively. In accordance with standard astromaterials curation practices, these cleanrooms will be monitored for particulate contamination and maintained to ISO 5 equivalent standards1. Since the samples in these collections are expected to contain prebiotic organic compounds that may help explain the origin of life on Earth, these labs will also be monitored for organic and biological contamination2. Samples from Ryugu arrived on Earth in December, 2020. After basic characterization in Japan, NASA received a subset of these samples at the astromaterials curation facility in Houston in December of 2021. OSIRIS-REx is expected to return samples in September, 2023. Here we present preliminary microbial monitoring results from monthly monitoring of these new labs and the connected microtomy and staging areas that support them, as they are being commissioned. We also compare these results to baseline values for other astromaterials curation labs. We will also briefly describe additional cleaning efforts employed to reduce the bioburden in these new cleanrooms. Methods: Microbial samples were collected from surfaces using a dry macrofoam swab (Puritan Brand 2518051PFRNDFD). Swabs were also opened in the lab but not touched to any surfaces to function as negative controls. Samples and controls were processed inside a class II biosafety cabinet to avoid inadvertent cross contamination. The swabs were suspended in 15 ml of PBS (Phosphate Buffered Saline) and vortexed for 20 seconds to remove cells from the swab surface. The PBS was used to inoculate Petri dishes filled with TSA (Tryptic Soy Agar), Blood Agar, or Reasoners 2 agar to check for microbial growth. Each plate was inoculated with 0.1 ml of PBS. The TSA and blood agar plates were incubated at 35˚C and the Reasoners 2 agar plates were incubated at 25˚C for seven days. Petri dishes filled with Potato dextrose agar, Saboraud dextrose agar, or Saboraud dextrose agar with 0.1 mg/ml of chloramphenicol, an antibiotic, were used to check for fungal growth. These plates were inoculated with 0.3 ml of PBS and incubated at 30˚C. The remaining PBS was frozen at -80 ˚C for DNA sequencing. After incubation, isolates were counted and reisolated for identification. Isolates were identified using the VITEK23 system or by sequencing a portion of the 16S rRNA gene for bacteria or the ribosomal internal transcribed spacer (ITS) for fungi. Sequencing was performed with an ABI 3500 Sanger sequencer. Results: During our initial sampling, six of the seven sites sampled (86%) displayed bacterial or fungal growth. Samples collected from the staging areas and microtomy labs are not included in this calculation since those areas are maintained at a lower ISO 7 equivalent cleanliness standard. A month later, only three of the seven sites (43%) displayed bacterial growth. No fungal growth was detected in the second sampling. Since new equipment had been introduced to the Hayabusa2 lab since the first round of sampling, an additional three sampling sites were included in the second round of sampling. None of these sites displayed microbial growth. These sites will be included in all future sampling efforts. Bacterial isolates have been identified from the following genera at multiple time points: Micrococcus, Staphylococcus, and Bacillus. Isolates from the genera: Microbacterium, Nocardioides, Methylocystis, and Microvirga were identified in the initial sampling, but were not present at later time points. Identification of fungal isolates is in progress. Results are summarized in Table 1. Discussion: The recovery rate or percentage of positive samples4 was initially 86%, which is higher than the median recovery rate for comparable ISO 5 equivalent curation labs like Stardust (33%), Hayabusa (33%), and Cosmic Dust (50%). However, after a month of operation, the recovery rate for these same sites decreased to 43%, which is similar to what we observe in comparable curation cleanrooms with no microbial control requirements. Adding in the new sampling sites further decreases the recovery rate to 30%. With the reduction in recovery rate, we also observed a decrease in microbial diversity. At the first time point, we observed at least 10 different bacterial species and at least two different fungi. This is a higher diversity than the median values for comparable ISO 5 equivalent labs (2-4 isolates per sampling event). After the second sampling, we observed at least 4 bacterial species and no fungi, which is more consistent with comparable labs. We expect the recovery rate and diversity in both labs to continue to decrease as routine operation continues. We will use ultrapure hydrogen peroxide to disinfect equipment and work areas prior to opening any sample containers. Most of the bacterial and fungal isolates were detected on samples from the cleanroom floors. This is consistent with baseline results from other curation labs. Organisms from the genera Bacillus, Staphylococcus, and Micrococcus that were repeatedly detected are common in cleanrooms and on human skin5,6. These organisms are generally thought to be introduced when people enter the cleanroom. Microbacterium, Nocardioides, and Microvirga have also previously been identified in astromaterials cleanrooms, but not as frequently as Bacillus, Staphylococcus, and Micrococcus. Methylocystis is a novel genus in the astromaterials cleanrooms, but it was identified with low accuracy (93% match in the sequenced region of the 16S rRNA gene) and further work is needed to confirm this identification. Microbacterium is a diverse genus with isolates identified from terrestrial and aquatic sediments. Some species of Microbacterium are capable of degrading complex organic compounds found in crude oil. The presence of these bacteria in the OSIRIS REx and Hayabusa2 cleanrooms should be closely monitored. Methylocystis is a genus of methanotrophic bacteria capable of oxidizing methane. If this identification proves to be correct and it is detected again, it should be closely monitored as well. Under nominal operating conditions, samples should not ever encounter the cleanroom floor or other high traffic areas. If we observe an increase in the bioburden in sensitive work areas that appears to be influenced by organism transfer from high traffic areas like the floors, we can employ additional hydrogen peroxide treatments to disinfect high traffic areas. Routine microbial monitoring of these labs will ensure that NASA’s astromaterials collections remain pristine and useful for scientific study. Table 1. Sampling Locations and Colony Counts Bacterial CFUa Fungal CFU Bacterial CFU Fungal CFU Lab - Location 11/2/2021 11/2/2021 12/13/2021 12/13/2021 H2b-Floor 4 8 1 0 H2-staging pass through 3 0 0 0 H2-microtomy pass through TNTCc 0 0 0 H2 Microscope 1 NA NA 0 0 H2 Microscope 2 NA NA 0 0 H2-Table NA NA 0 0 OREXd- microtomy pass through 0 0 6 0 OREX – Anteroom pass through 0 0 0 0 OREX – Floor 1 2 0 0 OREX Witness Foil Table 3 0 1 0 Staging-Floor 16 0 15 0 Microtomy-Floor 3 0 2 0 a: CFU = Colony Forming Unit b: H2 = Hayabusa2 Lab c: TNTC = too numerous to count d: OREX = OSIRIS-REx Lab References: 1. ISO 14644-1:2015 - Cleanrooms and associated controlled environments -- Part 1: Classification of air cleanliness by particle concentration. 37 (2015). 2. McCubbin, F. M. et al. Space Sci Rev 215, (2019). 3. Pincus, D. H. Encyclopedia of Rapid Microbiological Methods (2005). 4. The United States Pharmacopeial Convention. USP General Chapter <1116> 17, 784–794 (2013). 5. Sheraba, N. S., Yassin, A. S. & Amin, M. BMC Research Notes 3, 278 (2010). 6. Utescher, C. L. de A., Franzolin, M. R., Trabulsi, L. R. & Gambale, V. Brazilian Journal of Microbiology 38, 710–716 (2007).

A B Regberg↗