Engineering PapersSearch

Engineering topics

Justin Spring

Publications and source records attributed to Justin Spring.

Europan Molecular Indicators of Life Investigation (EMILI) for a Future Europa Lander Mission

The Europan Molecular Indicators of Life Investigation (EMILI) is an instrument concept being developed for the Europa Lander mission currently under study. EMILI will meet and exceed the scientific and technical/resource requirements of the organic composition analyzer identified as a core instrument on the Lander. EMILI tightly couples two complementary analytical techniques, based on 1) liquid extraction and processing with capillary electrophoresis and 2) thermal and chemical extraction with gas chromatography, to robustly detect, structurally characterize, and quantify the broadest range of organics and other Europan chemicals over widely-varying concentrations. Dual processing and analysis paths enable EMILI to perform a thorough characterization of potential molecular biosignatures and contextual compounds in collected surface samples. Here we present a summary of the requirements, design, and development status of EMILI with projected scientific opportunities on the Europa Lander as well as on other potential life detection missions seeking potential molecular biosignatures in situ.

Europa

Pneumatic Sampler (P-Sampler) for the Martian Moons Exploration (MMX)

The Martian Moons eXploration (MMX) mission, led by the Japanese Aerospace Exploration Agency (JAXA), will focus on the exploration of the two Martian moons – Phobos and Deimos (Figure 1). The spacecraft will perform close-up remote sensing and observations of both moons and collect a sample from Phobos for Earth sample return. MMX has set the two mission goals: (1) determining the origin of the Martian moons and (2) observing processes in the circumplanetary environment of Mars, based on remote sensing, in-situ observations, and laboratory analyses of returned samples of Phobos regolith [1-2]. To fulfill the mission goals, MMX employs a double sampling approach: Coring and Pneumatic Samplers (Figure 2).The Coring Sampler (C-Sampler), a core soil tube deployed by a robotic arm, providing access to the building blocks of Phobos beneath the surface (>2 cm), and also collect a mixture of near surface material. The P-Sampler, on the other hand, would selectively sample the surface veneer and provides reference of surface component with the C-Sampler. The double sampling system not only enhances the scientific merits of MMX but also reduces risks associated with the sampling of Phobos. Without enough knowledge of the physical and chemical properties, and the geotechnical conditions of the surface of Phobos (e.g., compositions, temperature gradient/variation, porosity, grain size distribution), having two sampling systems that utilize entirely different sampling approaches is prudent.

Dylan Van Dyne

Europa Luminescence Microscope

The Europa Luminescence Microscope (ELM) is an automated fluorescence and dark-field mi-croscope designed to meet key objectives defined in the NASA Europa Lander Study Report, includ-ing the identification and characterization of morphological biosignatures. ELM’s heritage stems from a 2U cubesat fluorescence microscope, the Fluorescence Analysis for In-situ Research (FLAIR) im-ager, designed and built at NASA Ames Research Center, for the autonomous study of microbial bi-ology in low Earth orbit. For the ELM implementation, a sample is autonomously manipulated with a microfluidic system using in-line filter sets to capture successively smaller particles on 10, 1.0, and 0.1 µm pore-size filters for imaging. For darkfield imaging, ELM uses ultraviolet and visible light to image organic and inorganic structures with submicron resolution. The ability to detect structural and chemical biosignatures as small as 0.2 µm in size is achieved by imaging native fluorescence and us-ing fluorescence microscopy stains to identify key molecular and structural indicators of microbial life (proteins, lipids, nucleic acids). To excite fluorescence, ELM uses LEDs with wavelengths centered near 265, 370, 470, and 530 nm and five emission bands. The use of multiple excitation and emission wavelengths for native fluorescence imaging not only enables the detection of different molecular species, but also their rough classification. Excitation at 265 nm allows for the detection of smaller polyaromatic hydrocarbons (PAHs; 1-5 rings), aromatic amino acids, and proteins with little to no interference from mineral fluorescence, given proper emission band selection. 370 and 470 nm light excites increasingly larger PAH structures (e.g., coronene) and larger aromatic biomolecules that may be present (e.g., protective pigments). Similarly, inorganic fluorescence can be characterized and sep-arated from organic fluorescence, allowing the recognition and in some cases classification, of miner-als and other abiotic particles. ELM is based upon work supported by the NASA COLDTech and ICEE-2 programs.

Microscope