New Mie Scattering Diffuse Targets Development and Characterization

Earth science remote sensing observations require the detection and measurement of light originating from bright targets, such as clouds, and darker targets, such as an open ocean. This requirement drives the need to design, develop, and characterize improved calibration targets in support of current and future NASA instruments. New diffuse targets to be used as spectral albedo calibration standards were developed and characterized. The new targets based on fused silica or/and pressed and sintered Polytetrafluoroethylene (PTFE) were developed to be Earth scene specific. The various reflectance levels are achieved by modifying the material parameters, thickness, and surface finish. The new targets were characterized in laboratory and simulated space environments. We acquired high accuracy reflectance and transmittance data using a precision optical scatterometer and spectrophotometer located in the NASA Goddard Space Flight Center (GSFC) Diffuser Calibration Lab. The Total hemispherical reflectance (THR) and Bidirectional Reflectance Distribution Function (BRDF) were measured over the range of solar incident and scattered elevation and azimuthal angles typically realized on orbit by remote sensing instruments. We intend to space certify the new calibration targets after concluding on-orbit testing on the International Space Stations (ISS) scheduled for the second half of 2023.

Georgi Georgiev

Landsat-8 TIRS Thermal Radiometric Calibration Status

The Landsat-8 Thermal Infrared Sensor (TIRS) has been acquiring two-band thermal infrared images of the Earth’s surface since 2013. The calibration of the two-band system has been monitored using the on-board calibrator and validated with vicarious calibration performed by NASA/JPL and RIT since launch. Soon after launch, it was discovered that the instrument had a significant stray light effect that was affecting the radiometric calibration. The stray light was corrected in the processing system in 2017. Since then, it has become apparent that there was an additional radiometric error, based on the vicarious calibration results. With a failure within the primary electronic system and subsequent switch to the redundant electronic system, the TIRS instrument effectively has two separate calibration regimes. The vicarious calibration found a statistically significant calibration error, primarily a constant over time, in Band 11 on the primary electronics (Feb 11,2013 through March 5,2015) of about -0.6K at 300K. The calibration error in Band 10 was smaller though still statistically significant at about 0.2K at 300K. On the redundant side(March 5,2015 to present), the calibration error is more signal dependent than time dependent. Both bands are affected, with Band 10 having an error between 1K and -0.4K (between 273-320K) and Band 11 having an error between 0.8K and -1.44K (between 273-320K).This calibration error will be corrected within the USGS Landsat Product Generation System with the release of Landsat Collection-2 products. The Collection-2 release also includes a correction to the relative radiometric calibration of TIRS data. Striping as a result of poor detector-to-detector normalization has been increasing in the imagery since launch. The TIRS relative radiometric calibration will be updated based on internal calibrator data to remove the stripes on a quarterly basis. The visible stripes are generally at 0.1-0.2% level, though there are some detectors in each band that have changed by 1% or more. The Collection-2 release will result in much more uniform TIRS images.

Julia A Barsi

An Inter-Comparison Exercise of Sentinel-2 Radiometric Validations Assessed by Independent Expert Groups

Copernicus is the European Union's Earth Observation and Monitoring programme, delivering free access to operational and historical environmental data to support applications in a wide range of societal benefit areas. To allow meaningful long-term environmental monitoring and robust decision-making, it is essential to ensure that satellite-retrieved products are of high quality and consistency. This paper describes the outputs of an international workshop on the radiometric calibration validation of the Copernicus Sentinel-2A and Sentinel-2B Multi-Spectral Instrument. A wide range of vicarious methodologies have been applied independently and then compared per type of target. All methods agree on the good radiometric performance of both Sentinel-2A and Sentinel-2B with respect to the mission requirements as well as on evidence of a slight bias between the two instruments. Comparisons of all these results are discussed to highlight the benefits and advantages of the methods as well as to propose potential improvements either for the methods themselves and/or for the comparison exercise.

Sentinel-2

Landsat-7 ETM+ Radiometric Calibration Status

Now in its 17th year of operation, the Enhanced Thematic Mapper + (ETM+), on board the Landsat-7 satellite, continues to systematically acquire imagery of the Earth to add to the 40+ year archive of Landsat data. Characterization of the ETM+ on-orbit radiometric performance has been on-going since its launch in 1999. The radiometric calibration of the reflective bands is still monitored using on-board calibration devices, though the Pseudo-Invariant Calibration Sites (PICS) method has proven to be an effect tool as well. The calibration gains were updated in April 2013 based primarily on PICS results, which corrected for a change of as much as -0.2%/year degradation in the worst case bands. A new comparison with the SADE database of PICS results indicates no additional degradation in the updated calibration. PICS data are still being tracked though the recent trends are not well understood. The thermal band calibration was updated last in October 2013 based on a continued calibration effort by NASA/Jet Propulsion Lab and Rochester Institute of Technology. The update accounted for a 0.31 W/sq m/ sr/micron bias error. The updated lifetime trend is now stable to within + 0.4K.

Julia A Barsi

Radiometric Calibration and Stability of the Landsat-8 Operational Land Imager (OLI)

Landsat-8 and its two Earth imaging sensors, the Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) have been operating on-orbit for 2 1/2 years. The OLI radiometric calibration, which is monitored using on-board lamps, on-board solar diffusers, the moon and vicarious calibration techniques has been stable to within 1% over this period of time. The Coastal Aerosol band, band 1, shows the largest change at about 1% over the period; all other bands have shown no significant trend. OLI bands 1- 4 show small discontinuities in response (+0.1% to 0.2%) beginning about 7 months after launch and continuing for about 1 month associated with a power cycling of the instrument, though the origin of the recovery is unclear. To date these small changes have not been compensated for, but this will change with a reprocessing campaign that is currently scheduled for Fall 2015. The calibration parameter files (each typically covering a 3 month period) will be updated for these observed gain changes. A fitted response to an adjusted average of the lamps, solar and lunar results will represent the trend, sampled at the rate of one value per CPF.

radiometric stability

Early Radiometric Performance of Landsat-9 Thermal Infrared Sensor

Landsat-9, launched on September 27, 2021, carries the Thermal Infrared Sensor (TIRS). The Landsat-9 TIRS is a close copy of the Landsat-8 TIRS instrument; it is a two spectral-band, pushbroom sensor with three Sensor Chip Assemblies (SCAs) that cover the 15-degree field-of-view. The primary radiometric change between the instruments is the addition of baffling in the Landsat-9 TIRS telescope to mitigate the stray light issue that has impacted the radiometric quality of Landsat-8 TIRS. The on-orbit radiometric performance is monitored using the on-board variable temperature blackbody and views of deep space. Maneuvers to look at and around the moon have provided an assessment of the stray light. The absolute calibration is monitored by vicarious calibration techniques by teams at NASA/Jet Propulsion Lab and the Rochester Institute of Technology. Landsat-9 completed a three-month commissioning phase in January 2022 and has been operational since February 2022. The instrument has demonstrated excellent radiometric performance, as assessed from the on-orbit measurements. The TIRS instrument is radiometrically stable to 0.1% within a power cycle, and has noise levels below 0.1K. The lunar scans and the vicarious calibration data provide evidence that the stray light has been effectively mitigated.

Landsat-9

A Vacuum-Compatible, Spectrally Tunable, Flat Panel Uniform Source for Testing Large Aperture Earth Observation Systems

Labsphere, Inc in conjunction with NASA GSFC and Genesis Engineering Solutions inc. has developed an innovative, fully T-VAC compatible, calibration spectro-radiometric illumination source with a highly uniform large-area rectangular flat panel active area. This source leverages a new shaped integration geometry to achieve high uniformity over a large active output area while maintaining a smaller and more robust overall form-factor when compared to previous designs or integrating spheres. This new illuminator also leverages a set of selectable LED arrays as well as broadband tungsten-halogen sources to provide multi-level, wide spectrum reference illumination to the VIIRS instrument over all optical sensor bands during pre-launch testing. The first unit has been demonstrated to meet its requirements using ambient technology and a fully-vacuum-compatible second unit is planned to allow testing for T-VAC campaigns. This technology is both flexible and capable of meeting the needs of many other instruments/missions requiring this type of test/calibration capability.

Jeff Holt

On-Orbit OCI Characterization Measurements from the first 6 Months of the PACE Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission has been providing data to the science community since April 2024. OCI is a hyperspectral imager, providing almost daily global coverage, at a spatial resolution of 1.2km. Its design specifications were optimized for ocean color and atmospheric applications, but terrestrial studies could benefit from its hyperspectral coverage as well. The ocean color requirements called for very high radiometric accuracy, which could benefit a wide variety of applications. This paper presents results from the first 6 months of on-orbit calibration and characterization measurements, including absolute calibration, spectral registration, temporal trending of radiometric sensitivity, signal to noise ratio, and linearity, with a focus on the commissioning results obtained in the first 2 months after launch.

calibration

On-Orbit OCI Characterization Measurements from the first 6 Months of the PACE Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission has been providing data to the science community since April 2024. OCI is a hyperspectral imager, providing almost daily global coverage, at a spatial resolution of 1.2km. Its design specifications were optimized for ocean color and atmospheric applications, but terrestrial studies could benefit from its hyperspectral coverage as well. The ocean color requirements called for very high radiometric accuracy, which could benefit a wide variety of applications. This paper presents results from the first 6 months of on-orbit calibration and characterization measurements, including absolute calibration, spectral registration, temporal trending of radiometric sensitivity, signal to noise ratio, and linearity, with a focus on the commissioning results obtained in the first 2 months after launch.