Engineering PapersSearch

Engineering topics

Juhasz, A. J.

Publications and source records attributed to Juhasz, A. J..

At least 19 records

The telescoping boom radiator concept for multimegawatt space power systems

Development of the telescoping boom radiator from concept studies through a detailed design is reviewed. Particular attention is given to the scaling law for specific mass of cylindrical radiator geometries and radiator mass projections for large scale heat rejection systems. The concept of the telescoping, cylindrical radiator is identified as a leading candidate for rejecting tens of megawatts of thermal energy while maintaining a reasonable launch.

Koester, J. K.

Analysis of closed cycle megawatt class space power systems with nuclear reactor heat sources

The analysis and integration studies of multimegawatt nuclear power conversion systems for potential SDI applications is presented. A study is summarized which considered 3 separate types of power conversion systems for steady state power generation with a duty requirement of 1 yr at full power. The systems considered are based on the following conversion cycles: direct and indirect Brayton gas turbine, direct and indirect liquid metal Rankine, and in core thermionic. A complete mass analysis was performed for each system at power levels ranging from 1 to 25 MWe for both heat pipe and liquid droplet radiator options. In the modeling of common subsystems, reactor and shield calculations were based on multiparameter correlation and an in-house analysis for the heat rejection and other subsystems.

Juhasz, A. J.

Advanced solar dynamic space power systems perspectives, requirements and technology needs

Projected NASA, Civil, Commercial, and Military missions will require space power systems of increased versatility and power levels. The Advanced Solar Dynamic (ASD) Power systems offer the potential for efficient, lightweight, survivable, relatively compact, long-lived space power systems applicable to a wide range of power levels (3 to 300 kWe), and a wide variety of orbits. The successful development of these systems could satisfy the power needs for a wide variety of these projected missions. Thus, the NASA Lewis Research Center has embarked upon an aggressive ASD reserach project under the direction of NASA's Office of Aeronautics and Space Technology (DAST). The project is being implemented through a combination of in-house and contracted efforts. Key elements of this project are missions analysis to determine the power systems requirements, systems analysis to identify the most attractive ASD power systems to meet these requirements, and to guide the technology development efforts, and technology development of key components.

Dustin, M. O.

Reliability and mass analysis of dynamic power conversion systems with parallel of standby redundancy

A combinatorial reliability approach is used to identify potential dynamic power conversion systems for space mission applications. A reliability and mass analysis is also performed, specifically for a 100 kWe nuclear Brayton power conversion system with parallel redundancy. Although this study is done for a reactor outlet temperature of 1100K, preliminary system mass estimates are also included for reactor outlet temperatures ranging up to 1500 K.

Juhasz, A. J.

Methods of reducing energy consumption of the oxidant supply system for MHD/steam power plants

An in-depth study was conducted to identify possible improvements to the oxidant supply system for combined cycle MHD power plants which would lead to higher thermal efficiency and reduction in the cost of electricity, COE. Results showed that the oxidant system energy consumption could be minimized when the process was designed to deliver a product O2 concentration of 70 mole percent. The study also led to the development of a new air separation process, referred to as 'liquid pumping and internal compression'. MHD system performance calculations show that the new process would permit an increase in plant thermal efficiency of 0.6 percent while allowing more favorable tradeoffs between magnetic energy and oxidant system capacity requirements.

Juhasz, A. J.

Optimization of the oxidant supply system for combined cycle MHD power plants

An in-depth study was conducted to determine what, if any, improvements could be made on the oxidant supply system for combined cycle MHD power plants which could be reflected in higher thermal efficiency and a reduction in the cost of electricity, COE. A systematic analysis of air separation process varitions which showed that the specific energy consumption could be minimized when the product stream oxygen concentration is about 70 mole percent was conducted. The use of advanced air compressors, having variable speed and guide vane position control, results in additional power savings. The study also led to the conceptual design of a new air separation process, sized for a 500 MW sub e MHD plant, referred to a internal compression is discussed. In addition to its lower overall energy consumption, potential capital cost savings were identified for air separation plants using this process when constructed in a single large air separation train rather than multiple parallel trains, typical of conventional practice.

Juhasz, A. J.

Comparative analysis of the conceptual design studies of potential early commercial MHD power plants (CSPEC)

A conceptual design study of the MHD/steam plant that incorporates the use of oxygen enriched air preheated in a metallic heat exchanger as the combustor oxidant showed that this plant is the most attractive for early commercial applications. The variation of performance and cost was investigated as a function of plant size. The contractors' results for the overall efficiencies are in reasonable agreement considering the slight differences in their plant designs. NASA LeRC is reviewing cost and performance results for consistency with those of previous studies, including studies of conventional steam plants. LeRC in house efforts show that there are still many tradeoffs to be considered for these oxygen enriched plants and considerable variations can be made in channel length and level of oxygen enrichment with little change in overall plant efficiency.

Sovie, R. J.

The optimization air separation plants for combined cycle MHD-power plant applications

Some of the design approaches being employed during a current supported study directed at developing an improved air separation process for the production of oxygen enriched air for magnetohydrodynamics (MHD) combustion are outlined. The ultimate objective is to arrive at conceptual designs of air separation plants, optimized for minimum specific power consumption and capital investment costs, for integration with MHD combined cycle power plants.

Juhasz, A. J.

Performance characteristics of two annular dump diffusers using suction-stabilized vortex flow control

The two diffusers employed in the investigation had the same overall area ratio but different prediffuser area ratios and suction slot geometries. Velocity profile and diffuser pressure recovery performance data were obtained at ambient pressure and temperature, with inlet Mach numbers ranging from 0.18 to 0.41 and suction rate varying from zero to 18% of total inlet mass flow rate. On the basis of the reported investigation it is concluded that suction stabilized vortex flow diffusers show promise for application in combustors because of relatively high static pressure recovery and low total pressure loss obtained in a short length. Performance obtained using a narrow angle (7 degree) prediffuser was superior to that obtained with a prediffuser having a 14 degree included angle.

Juhasz, A. J.

Performance of a short annular dump diffuser using suction-stabilized vortices at inlet Mach numbers to 0.41

A short, annular dump diffuser was designed to use suction to establish stabilized vortices on both walls for improved flow expansion in the region of an abrupt area change. The diffuser was tested at near ambient inlet pressure and temperature. The overall diffuser area ratio was 4.0. The inlet height was 2.54 cm and the exit pitot-static rakes were located at a distance from the vortex fence equal to two or six times the inlet height. Performance data were taken at near ambient temperature and pressure for nominal inlet Mach numbers of 0.18 to 0.41 with suction rates of 0 to 18 percent of the total inlet airflow. The exit velocity profile could be shifted toward either wall by adjusting the inner- or outer-wall suction rate. Symmetrical exit velocity profiles were unstable, with a tendency to shift back to hub- or tip-weighted profile. Diffuser effectiveness was increased from about 47 percent without suction to over 85 percent at a total suction rate of about 14 percent. The diffuser total pressure losses at inlet Mach numbers of 0.18 and 0.41 decreased from 1.1 and 5.6 percent without suction to 0.48 and 5.2 percent at total suction rates of 14.4 and 5.6 percent, respectively.

Smith, J. M.

Performance characteristics of two annular dump diffusers using suction-stabilized vortex flow control

Test results are described for two abrupt area change annular diffusers with provisions for maintaining suction stabilized toroidal vortices at the area discontinuity. Both diffusers had an overall area ratio of 4.0 with the prediffuser area ratio being 1.18 for diffuser A and 1.4 for diffuser B. Performance was evaluated at near atmospheric pressure and temperature for a range of inlet Mach numbers from 0.18 to 0.41 and suction rates from 0 to 18%. Static pressure recovery improved significantly as the suction rate was increased to approximately 11%. Results obtained with diffuser A were superior to that obtained with diffuser B. Flat radial profiles of exit velocity were not obtained since the flow showed preferential hub or tip attachment at moderate suction rates. At high suction rates the diffuser exit flow became circumferentially nonuniform and unstable.

Juhasz, A. J.

Emissions control for ground power gas turbines

The similarities and differences of emissions reduction technology for aircraft and ground power gas turbines is described. The capability of this technology to reduce ground power emissions to meet existing and proposed emissions standards is presented and discussed. Those areas where the developing aircraft gas turbine technology may have direct application to ground power and those areas where the needed technology may be unique to the ground power mission are pointed out. Emissions reduction technology varying from simple combustor modifications to the use of advanced combustor concepts, such as catalysis, is described and discussed.

Rudney, R. A.

Performance of high-area-ratio annular dump diffuser using suction-stabilized-vortex flow control

A short annular dump diffuser having a geometry conductive to formation of suction stabilized toroidal vortices in the region of abrupt area change was tested. The overall diffuser area ratio was 4.0 and the length to inlet height ratio was 2.0. Performance data were obtained at near ambient temperature and pressure for inlet Mach numbers of 0.18 and 0.30 with suction rates ranging from 0 to 18 percent of total inlet mass flowrate. Results show that the exit velocity profile could be readily biased toward either wall by adjustment of inner and outer wall suction rates. Symmetric exit velocity profiles were inherently unstable with a tendency to revert to a hub or tip bias. Diffuser effectiveness was increased from about 38 percent without suction to over 85 percent at a total suction rate of 10 to 12 percent. At the same time diffuser total pressure loss was reduced from 3.1 percent to 1.1 percent at an inlet Mach number of 0.3.

Juhasz, A. J.

Effect of wall suction on performance of a short annular diffuser at inlet Mach numbers up to 0.5

A short annular diffuser equipped with wall bleed (suction)capability was evaluated at inlet Mach numbers of 0.186 to 0.5. The diffuser had an area ratio of 4.0 and a length-to-inlet height ratio of 1.6. Test results show that the exit velocity profiles, typical of annular jet flow without suction, could be considerably flattened by application of wall suction. This improved performance was also reflected in diffuser effectiveness (static-pressure recovery) and total-pressure loss results. At the inlet Mach number of 0.5 diffuser static-pressure recovery is equal to or better than at lower inlet Mach numbers for comparable suction rates.

Juhasz, A. J.

Effect of wall edge suction on the performance of a short annular dump diffuser with exit passage flow resistance

The effect of wall edge suction on the performance of a short annular dump diffuser having a perforated plate flow resistance device in the exit passage was evaluated. Testing was conducted with air at near ambient pressure and temperature at inlet Mach numbers of 0.18 and 0.27 with suction rates up to 13.5 percent. Results show that pressure recovery downstream of the perforated plate was improved significantly by suction. Optimum performance was obtained with the flow resistance plate located at one inlet passage height downstream of the dump plane.

Juhasz, A. J.

Performance of a short annular dump diffuser using wall trailing-edge suction

A short annular dump (abrupt flow area change) diffuser was tested with suction through wall trailing-edge slots at inlet Mach numbers of 0.19 and 0.27 and at near ambient inlet temperature and pressure, with suction flow varied from zero to 10 percent of the inlet air mass-flow rate. The overall ratio of diffuser exit area to inlet area was 4.0, and the ratio of length to inlet height was 2.0. By applying suction flow separately on either wall or to both walls simultaneously, the original annular jet profile could be altered to either a hub- or tip-biased profile. Diffuser effectiveness was increased from about 25 percent with no suction to 50 percent at 6 percent outer-wall suction and to 52 percent at a combined suction rate on both walls of 10.25 percent. At the same time, diffuser total pressure loss was reduced by one-fourth.

Juhasz, A. J.

Effect of diffuser bleed on performance of an annular swirl can combustor

A full-scale annular swirl can combustor equipped with diffuser bleed capability was tested at low fuel-air ratio, burning natural gas fuel. Test results show that, by drawing off a small amount of air on the inner or outer diffuser wall, the radial profile of combustor exit temperature could be changed from a strongly tip biased, to a strongly hub biased shape. Furthermore, combustor total pressure loss could be reduced by about one third by using a total bleed rate equal to 6 percent of diffuser inlet flow. At simulated engine idle conditions combustion efficiency was increased from 64 percent to nearly 100 percent by using 3 percent outer wall bleed. Combustor blowout performance was also improved significantly by using this diffuser bleed scheme.

Juhasz, A. J.