Engineering PapersSearch

Engineering topics

Joy, Marshall

Publications and source records attributed to Joy, Marshall.

At least 37 records · Page 2

A Compact X-Ray System for Macromolecular Crystallography

We describe the design and performance of a high flux x-ray system for macromolecular crystallography that combines a microfocus x-ray generator (40 gm FWHM spot size at a power level of 46.5Watts) and a 5.5 mm focal distance polycapillary optic. The Cu K(sub alpha) X-ray flux produced by this optimized system is 7.0 times above the X-ray flux previously reported. The X-ray flux from the microfocus system is also 3.2 times higher than that produced by the rotating anode generator equipped with a long focal distance graded multilayer monochromator (Green optic; CMF24-48-Cu6) and 30% less than that produced by the rotating anode generator with the newest design of graded multilayer monochromator (Blue optic; CMF12-38-Cu6). Both rotating anode generators operate at a power level of 5000 Watts, dissipating more than 100 times the power of our microfocus x-ray system. Diffraction data collected from small test crystals are of high quality. For example, 42,540 reflections collected at ambient temperature from a lysozyme crystal yielded R(sub sym) 5.0% for the data extending to 1.7A, and 4.8% for the complete set of data to 1.85A. The amplitudes of the reflections were used to calculate difference electron density maps that revealed positions of structurally important ions and water molecules in the crystal of lysozyme using the phases calculated from the protein model.

Gubarev, Mikhail

Interferometry for X-Ray Astronomy

With direct imaging, the nature of distant astronomical objects and the physical mechanisms that control them can be constrained and understood. From Galileo's observations of the solar system, to Hubble Space Telescope's imaging of distant galaxies, improved astronomical imaging has always brought scientific understanding. The x-ray band of the spectrum, where exotic objects can have extremely high surface brightness, is ideally suited for high resolution imaging, but has lacked ultra-high quality telescopes. We report a practical x-ray interferometer that features high efficiency, affordable mirrors, adjustable baseline, and can be scaled to a full size observatory. Our prototype system, with just under one millimeter of baseline, created fringes at 1.25 keV with angular resolution of 100 milli-arcseconds. With a larger version of this interferometer in orbit it will be possible to resolve stars, black holes and other compact constituents of the universe. We can study the environments of pulsars, image and then model relativistic blast waves, study the space-time metric near the surface of a black hole, watch the physical formation of astrophysical jets, and study the dynamos of stellar coronae.

Cash, Webster

Sunyaev - Zel'dovich Effect Imaging of Massive Clusters of Galaxies at Redshift > 0.8

We present Sunyaev-Zel'dovich Effect (SZE) imaging observations of three distant (z greater than 0.8) and highly X-ray luminous clusters of galaxies, C1J1226+33, C1J0152-13 and MS1054-03. Two of the clusters, C1J1226+33 and C1J0152-13, were recently discovered in the WARPS X-ray survey. Their high X-ray luminosity suggests they are massive systems and, if confirmed, would provide strong constraints on the cosmological parameters of structure formation models. Our Sunyaev-Zel'dovich Effect data provide confirmation that they are massive clusters similar to the well studied cluster MS1054-03. Assuming the clusters have the same gas mass fraction derived from SZE measurements of eighteen known massive clusters, we are able to infer their mass and electron temperatures from the SZE data. The derived electron temperatures are 10.0, 8.5, and 10.3 KeV, respectively, and we infer total masses of approximately 2 x 10(circumflex) 14 h(circumflex) -l M - sun within a radius of 65" for all three clusters. For C1J0152-13 and MS1054-03 we find good agreement between our SZE derived temperatures and those derived from X-ray spectroscopic measurements. No X-ray derived temperatures are available for C1J1226+33, and thus the SZE data provide the first confirmation that it is indeed a massive system. The demonstrated ability to determine cluster temperatures and masses from SZE observations without access to X-ray data illustrates the power of using deep SZE surveys to probe the distant universe.

Joy, Marshall

First Results from a Microfocus X-Ray System for Macromolecular Crystallography

The design and performance of a 40 Watt laboratory crystallography system optimized for the structure determination of small protein crystals are described. This system combines a microfocus x-ray generator (40 microns FWHM spot size at a power level of 40 Watts) and a short focal length (F = 2.6 mm) polycapillary collimating optic, and produces a small diameter quasi-parallel x-ray beam. Measurements of x-ray flux, divergence and spectral purity of the resulting x-ray beam are presented. The x-ray flux in a 250 microns diameter aperture produced by the microfocus system is 14.7 times higher .than that from a 3.15 kW rotating anode generator equipped with graphite monochromator. Crystallography data taken with the microfocus system are presented, and indicate that the divergence and spectral purity of the x-ray are sufficient to refine the diffraction data using a standard crystallographic software. Significant additional improvements in flux and beam divergence are possible, and plans for achieving these coals are discussed.

Gubarev, Mikhail

Development of a Grazing Incidence X-Ray Interferometer

A grazing incidence x-ray interferometer design capable of micro-arcsecond level resolution is discussed. This practical design employs a Michelson Stellar interferometer approach to create x-ray interference fringes without the use of Wolter style optics or diffraction crystals. Design solutions accommodating alignment, vibration, and thermal constraints are reviewed. We present the development and demonstration of a working experiment along with tolerance studies, data analysis, and results.

Shipley, Ann

Grazing Incidence Optics for X-rays Interferometry

Grazing incidence mirror parameters and constraints for x-ray interferometry are described. We present interferometer system tolerances and ray trace results used to define mirror surface accuracy requirements. Mirror material, surface figure, roughness, and geometry are evaluated based on analysis results. We also discuss mirror mount design constraints, finite element analysis, environmental issues, and solutions. Challenges associated with quantifying high accuracy mirror surface quality are addressed and test results are compared with theoretical predictions.

Shipley, Ann

Radio Sources in Galaxy Clusters at 28.5 GHz

We present serendipitous observations of radio sources at 28.5 GHz (1 cm), which resulted from our program to image thermal Sunyaev-Zeldovich (SZ) effect in 56 galaxy clusters. In a total area of about 0.8 degrees sq., we find 64 radio sources with fluxes down to - 0.4 mJy (> 4sigma,), and within 250" from the pointing centers. The spectral indices (S varies as v(sup -alpha) of 54 sources with published low frequency flux densities range from -0.6 approximately < alpha and alpha approximately < 2 with a mean of 0.77 +/- 0.06, and a median of 0.84. Extending low frequency surveys of radio sources towards galaxy clusters CL 0016+16, Abell 665, and Abell 2218 to 28.5 GHz, and selecting sources with S(sub l.4GHz) >/= 7 mJy to form an unbiased sample, we find a mean spectral index of 0.71 +/- 0.08 and a median of 0.71. We find 4 to 7 times more sources predicted from a low frequency survey in areas without galaxy clusters. This excess cannot be accounted for by gravitational lensing of a background radio population by cluster potentials, indicating most of the detected sources are associated with galaxy clusters. The differential source count slope, gamma is approximately 1.96 (dN/dS varies as S(exp -gamma)), is flatter than what is expected for a nonevolving Euclidean population (gamma = 2.5). For the cluster Abell 2218, the presence of unsubtracted radio sources with S(sub 28.5GHz) is approximately < 0.5 mJy (- 5 sigma), can only contribute to temperature fluctuations at a level of DeltaT is approximately 10 to 25 microK. The corresponding error due to radio point source contamination in the Hubble constant derived through a combined analysis of 28.5 GHz SZ images and X-ray emission observations ranges from 1% to 6%.

Cooray, Asantha R.

ROSAT HRI images of Abell 85 and Abell 496: Evidence for inhomogeneities in cooling flows

We present ROSAT high-resolution images of two clusters of galaxies with cooling flows, Abell 496 and Abell 85. In these clusters, X-ray emission on small scales above the general cluster emission is significant at the 3 sigma level. There is no evidence for optical counterparts. If real, the enhancements may be associated with clumps of gas at a lower temperature and higher density than the ambient medium, or hotter, denser gas perhaps compressed by magnetic fields. These observations can be used to test models of how thermal instabilities form and evolve in cooling flows.

Prestwich, Andrea H.

ROSAT HRI images of Abell 85 and Abell 496: Evidence for inhomogeneities in cooling flows

We present ROSAT HRI images of two clusters of galaxies with cooling flows, Abell 496 and Abell 85. In these clusters, x-ray emission on small scales above the general cluster emission is significant at the 3 sigma level. There is no evidence for optical counterparts. The enhancements may be associated with lumps of gas at a lower temperature and higher density than the ambient medium, or hotter, denser gas perhaps compressed by magnetic fields. These observations can be used to test models of how thermal instabilities form and evolve in cooling flows.

Prestwich, Andrea H.

AXAF VETA-I mirror encircled energy measurements and data reduction

The AXAF VETA-I mirror encircled energy was measured with a series of apertures and two flow gas proportional counters at five X-ray energies ranging from 0.28 to 2.3 keV. The proportional counter has a thin plastic window with an opaque wire mesh supporting grid. Depending on the counter position, this mesh can cause the X-ray transmission to vary as much as +/- 9 percent, which directly translates into an error in the encircled energy. In order to correct this wire mesh effect, window scan measurements were made, in which the counter was scanned in both horizontal (Y) and vertical (Z) directions with the aperture fixed. Post VETA measurement of the VXDS setup were made to determine the exact geometry and position of the mesh grid. Computer models of the window mesh were developed to simulate the X-ray transmission based on this measurement. The window scan data were fitted to such mesh models and corrections were made. After this study, the mesh effect was well understood and the final results of the encircled energy were obtained with an uncertainty of less than 0.8 percent.

Zhao, Ping

AXAF VETA-I mirror encircled energy measurements and data reduction

The AXAF VETA-I mirror encircled energy was measured with a series of apertures and two flow gas proportional counters at five X-ray energies ranging from 0.28 to 2.3 keV. The proportional counter has a thin plastic window with an opaque wire mesh supporting grid. Depending on the counter position, this mesh can cause the X-ray transmission to vary as much as +/-9 percent, which directly translates into an error in the encircled energy. In order to correct this wire mesh effect, window scan measurements were made, in which the counter was scanned in both horizontal (Y) and vertical (Z) directions with the aperture fixed. Post VETA measurement of the VXDS setup were made to determine the exact geometry and position of the mesh grid. Computer models of the window mesh were developed to simulate the X-ray transmission based on this measurement. The window scan data were fitted to such mesh models and corrections were made. After this study, the mesh effect was well understood and the final results of the encircled energy were obtained with an uncertainty of less than 0.8 percent.

Zhao, Ping

Development of hard X-ray optics

Studies of cosmic X-ray sources have suffered from lack of focussing optics in the hard X-ray spectral region (E above 10 keV); in the absence of imaging optics, celestial X-rays are masked by the cosmic ray background, which severely degrades the detector sensitivity. There are several possible ways to develop grazing incidence imaging optics for this spectral region; we describe here one approach which utilizes numerous large diameter silicon wafers to form a flat-plate imaging telescope. A prototype imager of this type has been constructed, and we present measurements of surface quality, coalignment accuracy, and imaging ability.

Joy, Marshall

Cooling flows and the formation of massive halos in cD galaxies

X-ray brightness profiles of galaxy clusters frequently indicate the presence of a hot gaseous envelope, and theoretical models predict that numerous low-mass stars will be formed as these gaseous halos cool and contract toward the center of the cluster potential. In this Letter, the optical surface brightness profiles of the halos seen in six cooling flow galaxies are modeled, and it is concluded that the optical profiles and mass-to-light ratios are consistent with the cooling flow accretion hypothesis.

Prestwich, Andrea H.

Dust properties around evolved stars from far-infrared size limits

High angular resolution far-infrared scans were obtained of six stars surrounded by circumstellar dust shells believed to result from mass loss by the central star. None of the dust shells was clearly resolved at either 50 or 100 microns; the upper limits are in the range 4 to 10 arcsec. These size limits place constraints on the far-IR dust emissivity and dust density distribution. For one of the objects, AFGL 2343, larger than normal grains are almost certainly required. For several other stars, the size limits are much more consistent with dust having an emissivity law no steeper than 1/lambda in the 1-100-micron spectral region. For IRC + 10216, an earlier suggestion is confirmed that, assuming reasonable grain properties, a smooth radial dust distribution is not consistent with the scans and the energy distribution of the object.

Harvey, Paul M.

An infrared jet in Centaurus A - A link to the extranuclear activity in distant radio galaxies?

High-resolution NIR images of the visually obscured central region of Centaurus A (NGC 5128) were obtained with the University of Texas array camera on the AAT in June 1988, in order to investigate the effect of the active nucleus on the surrounding galaxy. The J (1.25 micron), H (1.65 micron), and K (2.2 micron) images of the central 40 arcsec of the galaxy revealed an emission feature extending about 10 arcsec northeast of the nucleus at the same position angle as the X-ray and radio jets. This jet is most prominent at the 1.25 micron wavelength, where its brightness was comparable to that of the nucleus. The observed properties of the 'infrared jet' were found to be similar to those seen in distant radio sources.

Joy, Marshall

The charged particle radiation environment for AXAF

The Advanced X Ray Astrophysics Facility (AXAF) will be subjected to several sources of charged particle radiation during its 15-year orbital lifetime: geomagnetically-trapped electrons and protons, galactic cosmic ray particles, and solar flare events. These radiation levels are presented for the AXAF orbit for use in the design of the observatory's science instruments.

Joy, Marshall

An infrared jet in Centaurus A (NGC 5128): Evidence for interaction between the active nucleus and the interstellar medium

In the present study, higher resolution near infrared images of the visually-obscured central region of Centaurus A were obtained in order to investigate the effects of the active nucleus on the surrounding galaxy. Researchers present J(1.25 microns), H(1.65 microns), and K(2.2 microns) images of the central 40 seconds of the galaxy, taken with the Univ. of Texas InSb array camera on the Anglo Australian 3.9 meter telescope. These images reveal a jet extending approx. 10 arcseconds to the northeast of the nucleus at the same position angle as the x ray and radio jets. The infrared jet is most prominent at the shortest wavelength (1.25 microns), where its brightness surpasses that of the nucleus. The blue appearance of the infrared jet is remarkable considering the heavy obscuration that is evident at visual wavelengths. The amount of reddening in the vicinity of the jet is determined from the measured colors of the stellar core of the galaxy, and this value is used to generate an extinction-corrected energy distribution. In contrast to previously studied optical and infrared jets in active nuclei, the short-wavelength prominence of the Cen A jet indicates that it cannot be attributed to synchrotron emission from a beam of relativistic electrons. The remaining viable mechanisms involve an interaction between the interstellar medium and the active nucleus: the infrared radiation from the jet may be due to emission from interstellar gas that has been entrained and heated by the flow of relativistic particles from the nucleus; alternatively, luminous blue stars may have been created by compression of interstellar material by the relativistic plasma. To investigate these proposed mechanisms, near-infrared spectroscopic studies of Cen A are in progress to look for collisionally excited molecular hydrogen emission lines and recombination lines from ionized gas.

Joy, Marshall

A near infrared spectroscopic study of the interstellar gas in the starburst core of M82

Researchers used the McDonald Observatory Infrared Grating Spectrometer, to complete a program of spatially resolved spectroscopy of M82. The inner 300 pc of the starburst was observed with 4 inch (50 pc) resolution. Complete J, H and K band spectra with resolution 0.0035 micron (lambda/delta lambda=620 at K) were measured at the near-infrared nucleus of the galaxy. Measurements of selected spectral features including lines of FeII, HII and H2 were observed along the starburst ridge-line, so the relative distribution of the diagnostic features could be understood. This information was used to better define the extinction towards the starburst region, the excitation conditions in the gas, and to characterize the stellar populations there.

Lester, Dan F.