Engineering Papers⌕ Search

Engineering topics

Jones, T. M.

Publications and source records attributed to Jones, T. M..

Liner implosion experiments driven by a dynamic screw pinch

This paper expands upon recent experimental results [Campbell et al., Phys. Rev. Lett. 125, 035001 (2020)], where thin-foil liner implosions were driven by a dynamic screw pinch (DSP) and found to have magneto-Rayleigh–Taylor instability (MRTI) amplitudes up to three times smaller than in implosions driven by a standard z-pinch (SZP). Here, the expanded discussion presented herein includes: (1) a detailed comparison of the MRTI growth measured in the experiment with that calculated from theory; (2) measurements of axial magnetic field injection into the liner interior prior to the implosion, as well as the subsequent compression of this field during the implosion; (3) an in-depth description of how the helical geometry of the DSP can result in earlier implosion and stagnation times relative to the SZP; and (4) particle-in-cell simulations showing different electron drift behavior in the anode–cathode gap of the DSP relative to the SZP, and how this difference may be related to the different current waveforms recorded during the experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stabilization of Liner Implosions via a Dynamic Screw Pinch

Magnetically driven implosions are susceptible to magnetohydrodynamic instabilities, including the magneto-Rayleigh-Taylor instability (MRTI). To reduce MRTI growth in solid-metal liner implo-sions, the use of a dynamic screw pinch (DSP) has been proposed [P. F. Schmit et al., Phys. Rev. Lett. 117, 205001 (2016)]. In a DSP con guration, a helical return-current structure surrounds the liner, resulting in a helical magnetic eld that drives the implosion. Here, we present the rst experimental tests of a solid-metal liner implosion driven by a DSP. Using the 1-MA, 100{200-ns COBRA pulsed-power driver, we tested three DSP cases (with peak axial magnetic elds of 2 T, 14 T, and 20 T) and a standard z-pinch (SZP) case (with a straight return-current structure and thus zero axial eld). The liners had an initial radius of 3.2 mm and were made from 650-nm-thick aluminum foil. Images collected during the experiments reveal that helical MRTI modes developed in the DSP cases, while non-helical (azimuthally symmetric) MRTI modes developed in the SZP case. Additionally, the MRTI amplitudes for the 14-T and 20-T DSP cases were smaller than in the SZP case. Speci cally, when the liner had imploded to half of its initial radius, the MRTI amplitudes for the SZP case and for the 14-T and 20-T DSP cases were, respectively, 1.1-0.3 mm, 0.7-0.2 mm, and 0.3-0.1 mm. Relative to the SZP, the stabilization obtained using the DSP agrees reasonably well with theoretical estimates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic and Power Feed Upgrades to the MAIZE Facility

The Michigan Accelerator for Inductive Z-pinch experiments (MAIZE) is a one stage, 1 MA, Linear Transformer Driver (LTD) at the University of Michigan. The MAIZE facility has been the site of various experimental studies, including wire array z-pinches for x-ray source development and cylindrical foil loads for implosion stability analysis. Here, in order to better understand and investigate these and other experiments, a 4- frame extreme ultraviolet (EUV) camera was implemented, the optical stability of a 12-frame laser shadowgraphy system was improved, B-dot probes were upgraded, and a Rogowski coil was constructed. New conical load hardware was also developed to reduce the inductance of the transmission line and thus improve the current delivered to the loads.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SLUDGE BATCH 4 BASELINE MELT RATE FURNACE AND SLURRY-FED MELT RATE FURNACE TESTS WITH FRITS 418 AND 510 (U)

Several Slurry-Fed Melt Rate Furnace (SMRF) tests with earlier projections of the Sludge Batch 4 (SB4) composition have been performed.1,2 The first SB4 SMRF test used Frits 418 and 320, however it was found after the test that the REDuction/OXidation (REDOX) correlation at that time did not have the proper oxidation state for manganese. Because the manganese level in the SB4 sludge was higher than previous sludge batches tested, the impact of the higher manganese oxidation state was greater. The glasses were highly oxidized and very foamy, and therefore the results were inconclusive. After resolving this REDOX issue, Frits 418, 425, and 503 were tested in the SMRF with the updated baseline SB4 projection. Based on dry-fed Melt Rate Furnace (MRF) tests and the above mentioned SMRF tests, two previous frit recommendations were made by the Savannah River National Laboratory (SRNL) for processing of SB4 in the Defense Waste Processing Facility (DWPF). The first was Frit 503 based on the June 2006 composition projections.3 The recommendation was changed to Frit 418 as a result of the October 2006 composition projections (after the Tank 40 decant was implemented as part of the preparation plan). However, the start of SB4 processing was delayed due to the control room consolidation outage and the repair of the valve box in the Tank 51 to Tank 40 transfer line. These delays resulted in changes to the projected SB4 composition. Due to the slight change in composition and based on preliminary dry-fed MRF testing, SRNL believed that Frit 510 would increase throughput in processing SB4 in DWPF. Frit 418, which was used in processing Sludge Batch 3 (SB3), was a viable candidate and available in DWPF. Therefore, it was used during the initial SB4 processing. Due to the potential for higher melt rates with Frit 510, SMRF tests with the latest SB4 composition (1298 canisters) and Frits 510 and 418 were performed at a targeted waste loading (WL) of 35%. The '1298 canisters' describes the number of equivalent canisters that would be produced from the beginning of the current contract period before SB3 is blended with SB4. The melt rate for the SMRF SB4/Frit 510 test was 14.6 grams/minute. Due to cold cap mounding problems with the SMRF SB4/Frit 418 feed at 50 weight % solids that prevented a melt rate determination, this feed was diluted to 45 weight % solids. The melt rate for this diluted feed was 8.9 grams/minute. A correction factor of 1.2 for estimating the melt rate at 50 weight % solids from 45 weight % solids test results (based on previous SMRF testing5) was then used to estimate a melt rate of 10.7 grams/minute for SB4/Frit 418 at 50 weight % solids. Therefore, the use of Frit 510 versus Frit 418 with SB4 resulted in a higher melt rate (14.6 versus an estimated 10.7 grams/minute). For reference, a previous SMRF test with SB3/Frit 418 feed at 35% waste loading and 50 weight % solids resulted in a melt rate of 14.1 grams/minute. Therefore, depending on the actual feed rheology, the use of Frit 510 with SB4 could result in similar melt rates as experienced with SB3/Frit 418 feed in the DWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗