Engineering Papers⌕ Search

Engineering topics

Jones, Michael G.

Publications and source records attributed to Jones, Michael G..

At least 109 records · Page 6

Development and Testing of a High Level Axial Array Duct Sound Source for the NASA Flow Impedance Test Facility

In this report both a frequency domain method for creating high level harmonic excitation and a time domain inverse method for creating large pulses in a duct are developed. To create controllable, high level sound an axial array of six JBL-2485 compression drivers was used. The pressure downstream is considered as input voltages to the sources filtered by the natural dynamics of the sources and the duct. It is shown that this dynamic behavior can be compensated for by filtering the inputs such that both time delays and phase changes are taken into account. The methods developed maximize the sound output while (i) keeping within the power constraints of the sources and (ii) maintaining a suitable level of reproduction accuracy. Harmonic excitation pressure levels of over 155dB were created experimentally over a wide frequency range (1000-4000Hz). For pulse excitation there is a tradeoff between accuracy of reproduction and sound level achieved. However, the accurate reproduction of a pulse with a maximum pressure level over 6500Pa was achieved experimentally. It was also shown that the throat connecting the driver to the duct makes it difficult to inject sound just below the cut-on of each acoustic mode (pre cut-on loading effect).

Johnson, Marty E.↗

High Temperature Acoustic Liner Technology

This paper describes work currently in progress at Langley on liner concepts that employ structures that may be suitable for broadband exhaust noise attenuation in high speed flow environments and at elevated temperatures characteristic of HSCT applications. Because such liners will need to provide about 10 dB suppression over a 2 to 3 octave frequency range, conventional single-degree-of-freedom resonant structures will not suffice. Bulk absorbers have the needed broadband absorption characteristic; however, at lower frequencies they tend to be inefficient.

Parrott, Tony L.↗

A Comparison of Signal Enhancement Methods for Extracting Tonal Acoustic Signals

The measurement of pure tone acoustic pressure signals in the presence of masking noise, often generated by mean flow, is a continual problem in the field of passive liner duct acoustics research. In support of the Advanced Subsonic Technology Noise Reduction Program, methods were investigated for conducting measurements of advanced duct liner concepts in harsh, aeroacoustic environments. This report presents the results of a comparison study of three signal extraction methods for acquiring quality acoustic pressure measurements in the presence of broadband noise (used to simulate the effects of mean flow). The performance of each method was compared to a baseline measurement of a pure tone acoustic pressure 3 dB above a uniform, broadband noise background.

Jones, Michael G.↗

Digital PIV Measurements of Acoustic Particle Displacements in a Normal Incidence Impedance Tube

Acoustic particle displacements and velocities inside a normal incidence impedance tube have been successfully measured for a variety of pure tone sound fields using Digital Particle Image Velocimetry (DPIV). The DPIV system utilized two 600-mj Nd:YAG lasers to generate a double-pulsed light sheet synchronized with the sound field and used to illuminate a portion of the oscillatory flow inside the tube. A high resolution (1320 x 1035 pixel), 8-bit camera was used to capture double-exposed images of 2.7-micron hollow silicon dioxide tracer particles inside the tube. Classical spatial autocorrelation analysis techniques were used to ascertain the acoustic particle displacements and associated velocities for various sound field intensities and frequencies. The results show that particle displacements spanning a range of 1-60 microns can be measured for incident sound pressure levels of 100-130 dB and for frequencies spanning 500-1000 Hz. The ability to resolve 1 micron particle displacements at sound pressure levels in the 100 dB range allows the use of DPIV systems for measurement of sound fields at much lower sound pressure levels than had been previously possible. Representative impedance tube data as well as an uncertainty analysis for the measurements are presented.

Humphreys, William M., Jr.↗

Validation of a Numerical Method for Determining Liner Impedance

This paper reports the initial results of a test series to evaluate a method for determining the normal incidence impedance of a locally reacting acoustically absorbing liner, located on the lower wall of a duct in a grazing incidence, multi-modal, non-progressive acoustic wave environment without flow. This initial evaluation is accomplished by testing the methods' ability to converge to the known normal incidence impedance of a solid steel plate, and to the normal incidence impedance of an absorbing test specimen whose impedance was measured in a conventional normal incidence tube. The method is shown to converge to the normal incident impedance values and thus to be an adequate tool for determining the impedance of specimens in a grazing incidence, multi-modal, nonprogressive acoustic wave environment for a broad range of source frequencies.

Watson, Willie R.↗

A finite element propagation model for extracting normal incidence impedance in nonprogressive acoustic wave fields

A propagation model method for extracting the normal incidence impedance of an acoustic material installed as a finite length segment in a wall of a duct carrying a nonprogressive wave field is presented. The method recasts the determination of the unknown impedance as the minimization of the normalized wall pressure error function. A finite element propagation model is combined with a coarse/fine grid impedance plane search technique to extract the impedance of the material. Results are presented for three different materials for which the impedance is known. For each material, the input data required for the prediction scheme was computed from modal theory and then contaminated by random error. The finite element method reproduces the known impedance of each material almost exactly for random errors typical of those found in many measurement environments. Thus, the method developed here provides a means for determining the impedance of materials in a nonprogressirve wave environment such as that usually encountered in a commercial aircraft engine and most laboratory settings.

Watson, Willie R.↗

Measuring Fluctuating Pressures With Recessed Gauges

Report discusses use of pressure gauges mounted in recesses in interior wall of model scramjet engine. Consists of brief memorandum plus excerpts from NASA Technical Paper 3189, "Unsteady Pressure Loads In A Generic High-Speed Engine Model." Focuses mainly on factors affecting accuracy of gauge readings.

Parrott, Tony L.↗

Unsteady loads measurements in a generic high speed engine model by means of recessed transducers

Results are presented from measurements of unsteady loads during performance tests of a generic high-speed engine model, which were made using high-frequency pressure gages installed in existing calorimeter ports of the engine model and recessed into the interior wall surface in order to reduce thermal flux to the gage diaphragm. In was found that the boundary layer pressure spectra at the model wall start to deviate from their flat plate counterpart at a short distance into the model inlet, which suggests the contributions to the spectra from the shock/boundary layer interaction. It was also found that significant levels of combustion noise propagate up through the subsonic portion of the boundary layer well into the inlet region. At the condition of an unstart, the combustion noise apparently couples with the acoustic modes of the model to cause acoustic 'hot spots' well upstream of the combustor.

Parrott, Tony L.↗

Unsteady pressure loads in a generic high speed engine model

Unsteady pressure loads were measured along the top interior wall of a generic high-speed engine (GHSE) model undergoing performance tests in the combustion-Heated Scramjet Test Facility at the Langley Research Center. Flow to the model inlet was simulated at 72000 ft and a flight Mach number of 4. The inlet Mach number was 3.5 with a total temperature and pressure of 1640 R and 92 psia. The unsteady pressure loads were measured with 5 piezoresistive gages, recessed into the wall 4 to 12 gage diameters to reduce incident heat flux to the diaphragms, and distributed from the inlet to the combustor. Contributors to the unsteady pressure loads included boundary layer turbulence, combustion noise, and transients generated by unstart loads. Typical turbulent boundary layer rms pressures in the inlet ranged from 133 dB in the inlet to 181 dB in the combustor over the frequency range from 0 to 5 kHz. Downstream of the inlet exist, combustion noise was shown to dominate boundary layer turbulence noise at increased heat release rates. Noise levels in the isolator section increased by 15 dB when the fuel-air ratio was increased from 0.37 to 0.57 of the stoichiometric ratio. Transient pressure disturbances associated with engine unstarts were measured in the inlet and have an upstream propagation speed of about 7 ft/sec and pressure jumps of at least 3 psia.

Parrott, Tony L.↗

Tests Of Shear-Flow Model For Acoustic Impedance

Tests described in report conducted to validate two-dimensional shear-flow analytical model for determination of acoustic impedance of acoustic liner in grazing-incidence, grazing-flow environment by use of infinite-waveguide method. Tests successful for both upstream and downstream propagations. Work has potential for utility in testing of engine ducts in commercial aircraft.

Parrot, Tony L.↗

Fluctuating pressures measured beneath a high-temperature, turbulent boundary layer on a flat plate at Mach number of 5

Fluctuating pressures were measured beneath a Mach 5, turbulent boundary layer on a flat plate with an array of piezoresistive sensors. The data were obtained with a digital signal acquisition system during a test run of 4 seconds. Data sampling rate was such that frequency analysis up to 62.5 kHz could be performed. To assess in situ frequency response of the sensors, a specially designed waveguide calibration system was employed to measure transfer functions of all sensors and related instrumentation. Pressure time histories were approximated well by a Gaussian prohibiting distribution. Pressure spectra were very repeatable over the array span of 76 mm. Total rms pressures ranged from 0.0017 to 0.0046 of the freestream dynamic pressure. Streamwise, space-time correlations exhibited expected decaying behavior of a turbulence generated pressure field. Average convection speed was 0.87 of freestream velocity. The trendless behavior with sensor separation indicated possible systematic errors.

Parrott, Tony L.↗

Airfoil profile drag increase due to acoustic excitation

A two-dimensional airfoil (NACA-0009) is subjected to high intensity pure-tone sound over a 1-5 kHz frequency range while immersed in a flow with 240 ft/sec velocity in a quiet flow facility with a Reynolds number of 3 million. Wake dynamic pressures are determined, and the momentum deficit is used to calculate a two-dimensional drag coefficient. Significant increases in drag are observed when the airfoil is subjected to high-intensity sound at critical frequencies. The increased drag is accompanied by movement of the natural transition location. When the transition is fixed by roughness at 10 percent chord, no further transition movement is observed in response to an acoustic Tollmien-Schlichting disturbance. However, a 4 percent increase in the sectional drag coefficient is noted. It is believed to be due to the sound exciting the flow near the airfoil surface (shear layer), thus causing the existing turbulence to become more intense, possess a higher mixing rate (momentum), and increase the skin friction.

Shearin, John G.↗

Evaluation of a multi-point method for determining acoustic impedance

A multipoint method for determining acoustic impedance was evaluated in comparison with the traditional standing wave and two-microphone methods using 30 test samples covering the reflection factor magnitude range 0.004-0.999. The multipoint method is shown to combine the strengths of the standing wave and two-microphone methods while avoiding some of their inherent weaknesses. In particular, the results obtained suggest that the multipoint method will be less subject to flow induced random error than the two-microphone method in the presence of significant broadband noise levels associated with mean flow.

Jones, Michael G.↗

An operations manual for the digital data system

The Digital Data System (DDS) was designed to incorporate the analog-to-digital conversion process into the initial data acquisition stage and to store the data in a digital format. This conversion is done as part of the acquisition process. Consequently, the data are ready to be analyzed as soon as the test is completed. This capability permits the researcher to alter test parameters during the course of the experiment based on the information acquired in a prior portion of the test. The DDS is currently able to simultaneously acquire up to 10 channels of data. The purpose of this document is fourfold: (1) to describe the capabilities of the hardware in sufficient detail to allow the reader to determine whether the DDS is the optimum system for a particular experiment; (2) to present some of the more significant software developed to provide analyses within a short time of the completion of data acquisition; (3) to provide the reader with sample runs of major software routines to demonstrate their convenience and simple usage; and (4) a portion of the document is used to describe software which uses an FFT-box to provide a means of comparison against which the DDS can be checked.

Jones, Michael G.↗

Evaluation of a multi-point method for determining acoustic impedance

An investigation was conducted to explore potential improvements provided by a Multi-Point Method (MPM) over the Standing Wave Method (SWM) and Two-Microphone Method (TMM) for determining acoustic impedance. A wave propagation model was developed to model the standing wave pattern in an impedance tube. The acoustic impedance of a test specimen was calculated from a best fit of this standing wave pattern to pressure measurements obtained along the impedance tube centerline. Three measurement spacing distributions were examined: uniform, random, and selective. Calculated standing wave patterns match the point pressure measurement distributions with good agreement for a reflection factor magnitude range of 0.004 to 0.999. Comparisons of results using 2, 3, 6, and 18 measurement points showed that the most consistent results are obtained when using at least 6 evenly spaced pressure measurements per half-wavelength. Also, data were acquired with broadband noise added to the discrete frequency noise and impedances were calculated using the MPM and TMM algorithms. The results indicate that the MPM will be superior to the TMM in the presence of significant broadband noise levels associated with mean flow.

Jones, Michael G.↗

Measured and calculated acoustic attenuation rates of tuned resonator arrays for two surface impedance distribution models with flow

An experiment was performed to validate two analytical models for predicting low frequency attenuation of duct liner configurations built from an array of seven resonators that could be individually tuned via adjustable cavity depths. These analytical models had previously been developed for high frequency aero-engine inlet duct liner design. In the low frequency application, the liner surface impedance distribution is unavoidably spatially varying by virtue of available fabrication techniques. The characteristic length of this spatial variation may be a significant fraction of the acoustic wavelength. Comparison of measured and predicted attenuation rates and transmission losses for both modal decomposition and finite element propagation models were in good to excellent agreement for a test frequency range that included the first and second cavity resonance frequencies. This was true for either of two surface impedance distribution modeling procedures used to simplify the impedance boundary conditions. In the presence of mean flow, measurements revealed a fine scale structure of acoustic hot spots in the attenuation and phase profiles. These details were accurately predicted by the finite element model. Since no impedance changes due to mean flow were assumed, it is concluded that this fine scale structure was due to convective effects of the mean flow interacting with the surface impedance nonuniformities.

Parrott, Tony L.↗

Status report on a natural laminar-flow nacelle flight experiment

The natural laminar flow (NLF) nacelle experiment is part of a drag reduction production program, and has the dual objectives of studying the extent of NLF on full scale nacelles in a flight environment and the effect of acoustic disturbance on the location of transition on the nacelle surface. The experiment is being conducted in two phases: (1) an NLF fairing was flown on a full scale Citation nacelle to develop the experiment technique and establish feasibility; (2) full scale, flow through, NLF nacelles located below the right wing of an experimental NASA OV-1 aircraft are evaluated. The measurements of most interest are the static pressure distribution and transition location on the nacelle surface, and the fluctuating pressure levels associated with the noise sources. Data are collected in combinations of acoustic frequencies and sound pressure levels. The results of phase 2 tests to date indicate that on shape GE2, natural laminar flow was maintained as far aft as the afterbody joint at 50 percent of the nacelle length. An aft facing step at this joint caused premature transition at this station. No change was observed in the transition pattern when the noise sources were operated.

Hastings, Earl C., Jr.↗

Effects of acoustic sources

An experiment was conducted to determine the effect of acoustics on the laminar flow on the side of a nacelle. A flight test was designed to meet this goal and a brief review of the purpose is given. A nacelle with a significant length of laminar flow was mounted on the wing of NASA OV-1. Two noise sources are also mounted on the wing: one in the center body of the nacelle; the second in a wing mounted pod outboard of the nacelle. These two noise sources allow for a limited study of the effect of source direction in addition to control of the acoustic level and frequency. To determine the range of Tollmien-Schlichting frequencies, a stability analysis using the pressure coefficient distribution along the side of the nacelle was performed. Then by applying these frequencies and varying the acoustic level, a study of the receptivity of the boundary layer to the acoustic signal, as determined by the shortening of the length of laminar flow, was conducted. Results are briefly discussed.

Schoenster, James A.↗