Engineering Papers⌕ Search

Engineering topics

Jones, B.

Publications and source records attributed to Jones, B..

At least 55 records · Page 3

Basis set expansion for inverse problems in plasma diagnostic analysis

A basis set expansion method [V. Dribinski, A. Ossadtchi, V. A. Mandelshtam, and H. Reisler, Rev. Sci. Instrum. 73, 2634 (2002)] is applied to recover physical information about plasma radiation sources from instrument data, which has been forward transformed due to the nature of the measurement technique. This method provides a general approach for inverse problems, and we discuss two specific examples relevant to diagnosing fast z pinches on the 20–25 MA Z machine [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats, J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K. W. Struve, W. A. Stygar, L. K. Warne, J. R. Woodworth, C. W. Mendel, K. R. Prestwich, R. W. Shoup, D. L. Johnson, J. P. Corley, K. C. Hodge, T. C. Wagoner, and P. E. Wakeland, in Proceedings of the Pulsed Power Plasma Sciences Conference (IEEE, 2007), p. 979]. First, Abel inversion of time-gated, self-emission x-ray images from a wire array implosion is studied. Second, we present an approach for unfolding neutron time-of-flight measurements from a deuterium gas puff z pinch to recover information about emission time history and energy distribution. Through these examples, we discuss how noise in the measured data limits the practical resolution of the inversion, and how the method handles discontinuities in the source function and artifacts in the projected image. We add to the method a propagation of errors calculation for estimating uncertainties in the inverted solution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Architecture, implementation, and testing of a multiple-shell gas injection system for high current implosions on the Z accelerator

Tests are ongoing to conduct {approx}20 MA z-pinch implosions on the Z accelerator at Sandia National Laboratory using Ar, Kr, and D{sub 2} gas puffs as the imploding loads. The relatively high cost of operations on a machine of this scale imposes stringent requirements on the functionality, reliability, and safety of gas puff hardware. Here we describe the development of a prototype gas puff system including the multiple-shell nozzles, electromagnetic drivers for each nozzle's valve, a UV pre-ionizer, and an inductive isolator to isolate the {approx}2.4 MV machine voltage pulse present at the gas load from the necessary electrical and fluid connections made to the puff system from outside the Z vacuum chamber. This paper shows how the assembly couples to the overall Z system and presents data taken to validate the functionality of the overall system.

42 ENGINEERING↗

K-α emission spectroscopic analysis from a Cu Z-pinch

Advances in diagnostic techniques at the Sandia Z-facility have facilitated the production of very detailed spectral data. In particular, data from the copper nested wire-array shot Z1975 provides a wealth of information about the implosion dynamics and ionization history of the pinch. Besides the dominant valence K- and L-shell lines in Z1975 spectra, K-α lines from various ionization stages were also observed. K-shell vacancies can be created from inner-shell excitation and ionization by hot electrons and from photo-ionization by high-energy photons; these vacancies are subsequently filled by Auger decay or resonance fluorescence. The latter process produces the K-α emission. For plasmas in collisional equilibrium, K-α emission usually occurs from highly charged ions due to the high electron temperatures required for appreciable excitation of the K-α transitions. Our simulation of Z1975 was carried out with the NRL 1-D DZAPP non-LTE radiation-hydrodynamics model, and the resulting K- and L-shell synthetic spectra are compared with measured radiation data. Our investigation will focus on K-α generation by both impacting electrons and photons. Synthetic K-α spectra will be generated either by self-consistently calculating the K-shell vacancy production in a full Z-pinch simulation, or by post-processing data from a simulation. The analysis of these K-α lines as well as K- and L-shell emission from valence electrons should provide quantitative information about the dynamics of the pinch plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of spatially resolved Z-pinch spectra to investigate the nature of 'bright spots'

Localized, intensely radiating regions are often observed in Z pinches. High resolution images of such areas have been recorded at least as far back as the 1970s. However, there is as yet no widely accepted consensus on the nature of these 'bright spots' or how they are formed. This phenomenon has also been referred to 'hot spots' or 'micropinches.' To shed further light on this issue, we have analyzed axially resolved K-shell spectra from 4 Z pinches driven by the refurbished Z generator ('ZR') at Sandia National Laboratories, and the previous version of the Z machine ('Z'). The atomic numbers of the loads varied from 13 to 29. We find that higher spatial K-shell intensity in the Al pinch correlates with density. The K-shell intensity within a copper shot taken on ZR correlates strongly with increased electron temperature, but another, somewhat less well-diagnosed copper shot from Z shows correlation with density. The bright spots in a Ti pinch correlate with neither density nor temperature, but do correlate with the product of density and diameter (proportional to opacity). This opacity correlation is also observed in the other 3 pinches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design, Development and Testing of the Miniature Autonomous Extravehicular Robotic Camera (Mini AERCam) Guidance, Navigation and Control System

Engineers at NASA Johnson Space Center have designed, developed, and tested a nanosatellite-class free-flyer intended for future external inspection and remote viewing of human spaceflight activities. The technology demonstration system, known as the Miniature Autonomous Extravehicular Robotic Camera (Mini AERCam), has been integrated into the approximate form and function of a flight system. The primary focus has been to develop a system capable of providing external views of the International Space Station. The Mini AERCam system is spherical-shaped and less than eight inches in diameter. It has a full suite of guidance, navigation, and control hardware and software, and is equipped with two digital video cameras and a high resolution still image camera. The vehicle is designed for either remotely piloted operations or supervised autonomous operations. Tests have been performed in both a six degree-of-freedom closed-loop orbital simulation and on an air-bearing table. The Mini AERCam system can also be used as a test platform for evaluating algorithms and relative navigation for autonomous proximity operations and docking around the Space Shuttle Orbiter or the ISS.

Wagenknecht, J.↗

Bolometric detectors for the high frequency instrument on the Planck surveyor

The High Frequency Instrument (HFI) on Planck will obtain all-sky images of the Cosmic Microwave Background (CMB) and other astrophysical sources of emission with resolution of 9 arcniin at 100 GHz, 7 arcmin at 143 GHz and 5 arcniin at 217, 353, 545 and 857 GHz. The HFI focal plane will contain 48 silicon nitride micromesh bolometric detectors operating from a 100 mK heat sink. Four detectors in each of the 6 bands will detect the sum of the power in both linear polarizations. An additional 4 pair of detectors will provide sensitivity to linear polarization of emission at 143, 217 and 353 GHz. We report on the development of these detectors, which are being produced at the JPL Micro Devices Laboratory, packaged at JPL Electronics Packaging, characterized at 100 mK before delivery to our HFI consortium partners at the UWCC, UK.

Planck CMB bolometer↗

Laser Micromachining Fabrication of THz Components

Laser micromachining techniques can be used to fabricate high-quality waveguide structures and quasi-optical components to micrometer accuracies. Successful GHz designs can be directly scaled to THz frequencies. We expect this promising technology to allow the construction of the first fully integrated THz heterodyne imaging arrays. At the University of Arizona, construction of the first laser micromachining system designed for THz waveguide components fabrication has been completed. Once tested and characterized our system will be used to construct prototype THz lx4 focal plane mixer arrays, magic tees, AR coated silicon lenses, local oscillator source phase gratings, filters and more. Our system can micro-machine structures down to a few microns accuracy and up to 6 inches across in a short time. This paper discusses the design and performance of our micromachining system, and illustrates the type, range and performance of components this exciting new technology will make accessible to the THz community.

DrouetdAubigny, C.↗

Constraints on the nucleus and dust properties from mid-infrared imaging of comet Hyakutake

We use Mie scattering theory to determine the expected thermal emission from dust grains in cometary comae and apply these results to mid-infrared images of comet Hyakutake (C/1996 B2) obtained preperihelion in 1996 March. Calculations were performed for dust grains in the size range from 0.1 to 10 micrometers for two different compositions: amorphous olivine (a silicate glass) and an organic residue mixture. The resulting emission efficiencies are complicated functions of wavelength and particle size and are significantly different for the two materials in question. The Hyakutake data set consists of three nights of high-resolution imaging (100-150 km pixel-1 at the comet) of the inner coma at 8.7, 11.7, 12.5, and 19.7 micrometers. Attempts to fit the observed colors (ratios of fluxes at different wavelengths) using a single grain composition failed. However, fits to the data were achieved for all three nights using a mixture of approximately 1 micrometer olivine grains and approximately 7 micrometers organic grains. The resulting olivine mass fraction was between 8% and 16% of the total dust mass-loss rate. We also estimate the radius of the nucleus to be r = 2.1 +/- 0.4 km.

Non-NASA Center↗

10 and 20 micron imaging with arrays

We discuss imaging with arrays in the thermal IR. Aspects of the design and performance of the 'Golden Gopher', an infrared array camera are presented. This instrument operates in a high-background environment, for ground-based astronomical imaging from 5 to 27 micrometers. It is built around a 20 x 64 element Si:As Impurity Band Conduction (IBC) device manufactured by GenCorp Aerojet Electronic Systems Division, and has a noise-equivalent flux density (NEFD) of 23.5 mJy (min(exp -1/2) (arcsec(exp -2) at lambda = 10 micrometers, delta-lambda = 1 micrometer, on the Mt. Lemmon 1.5m telescope. We present and discuss a sample of the data. In addition we discuss the design and expected performance of the 'Long Wavelength Spectrometer' which is now under construction for the Keck telescope.

Jones, B.↗

12 and 20 micron imaging of the starburst galaxy NGC 253

The study presents 12- and 20-micron imaging of the starburst galaxy NGC 253 with a spatial resolution of 0.8 arcsec. A positional uncertainty of 1.6 arcsec in these images is estimated on the basis of previous ground-based mid-IR studies to determine the absolute position of the images. It is concluded that the proposed 'nucleus' of NGC 253, i.e., the dominant, bright, flat-spectrum radio source identified by Turner & Ho (1985) (TH 2), is not associated with the mid-IR peak, but rather is located 2.2 arcsec to the northeast. The mid-IR peak, IRS 1, is placed midway between TH 6 and TH 7. Several coincidences with the present 12-micron image are found: IRS 1 falls within 1 arcsec of the 2-micron peak; a second significantly weaker IR source, IRS 2, coincides with TH 2; and the brightest steep-spectrum 6-cm radio source, TH 9, coincides with a 'tongue' of emission extending to the southwest of IRS 1.

Pina, R. K.↗

Imaging and spectroscopic studies of the interacting system Markarian 171

V, R, and I broadband CCD images, as well as H-alpha spectroscopic observations of Markarian 171, are presented. Two apparently interacting dust-enshrouded galaxies exhibit relatively normal V-R, V-I galactic stellar-population colors in their outer regions, and spatially extended H-alpha emission. However, the dereddened colors imply a hot stellar population. The dual characteristics of narrow H-alpha lines and spatially extended H-alpha emission clearly distinguish this type of activity from that associated with the compact central regions of active galactic nuclei and QSOs. Apparently, in the case of Mk 171 the interaction has induced star formation throughout a significant fraction of the galaxy (kiloparsecs) - not just in the immediate vicinity of the nucleus (parsecs). A peculiar stellar population of hot stars associated with a knot of weak H-alpha emission appears spatially separate from the other emission-line regions. It is possible that this stellar knot is a severed remnant attributable to the gravitational interaction between the two galaxies.

Friedman, Scott D.↗

Development of optimized detector/spectrophotometer technology for low background space astronomy missions

This program was directed towards a better understanding of some of the important factors in the performance of infrared detector arrays at low background conditions appropriate for space astronomy. The arrays were manufactured by Aerojet Electrosystems Corporation, Azusa. Two arrays, both bismuth doped silicon, were investigated: an AMCID 32x32 Engineering mosiac Si:Bi accumulation mode charge injection device detector array and a metal oxide semiconductor/field effect transistor (MOS-FET) switched array of 16x32 pixels.

Jones, B.↗

Abundances in galactic H II regions. III - G25.4-0.2, G45.5+0.06, M8, S159, and DR 22

Measurements of the ARII (6.99 microns), ArIII (8.99 microns), NeI (12.81 microns), SIII (18.71 microns), and SIV (10.51 microns) lines are presented for five compact HII regions along with continuum spectroscopy. From these data and radio data, lower limits to the elemental abundances of Ar, S, and Ne were deduced. The complex G25.4-0.2 is only 5.5 kpc from the galactic center, and is considerably overabundant in all these elements. Complex G45.5+0.06 is at seven kpc from the galactic center, and appears to be approximately consistent with solar abundance. The complex S159 in the Perseus Arm, at 12 kpc from the galactic center, has solar abundance, while M8 in the solar neighborhood may be somewhat overabundant in Ar and Ne. Complex DR 22, at 10 kpc from the galactic center in the Cygnus Arm, is overabundant in Ar. A summary of results from a series of papers on abundances is given.

Pipher, J. L.↗

Abundances in galactic H2 regions, 3: G25.4-0.2, G45.5+0.06, M8, S159 and DR22

Measurements of the ARII (6.99 microns), ArIII (8.99 microns), NeII (12.81 microns), SIII (18.71 microns), and SIV (10.51 microns) lines are presented for five compact HII regions along with continuum spectroscopy. From these data and radio data, lower limits to the elemental abundances of Ar, S, and Ne were deduced. The complex G25.4-0.2 is only 5.5 kpc from the galactic center, and is considerably overabundant in all these elements. Complex G45.5+0.06 is at seven kpc from the galactic center, and appears to be approximately consistent with solar abundance. The complex S159 in the Perseus Arm, at 12 kpc from the galactic center, has solar abundance, while M8 in the solar neighborhood may be somewhat overabundant in Ar and Ne. Complex DR 22, at 10 kpc from the galactic center in the Cygnus Arm, is overabundant in Ar. A summary of results from a series of papers on abundances is given.

Pipher, J. L.↗

Infrared astronomy research and high altitude observations

Highlights are presented of studies of the emission mechanisms in the 4 to 8 micron region of the spectrum using a circular variable filter wheel spectrometer with a PbSnTe photovoltaic detector. Investigations covered include the spectroscopy of planets, stellar atmospheres, highly obscured objects in molecular clouds, planetary nebulae, H2 regions, and extragalactic objects.

Jones, B.↗