Engineering PapersSearch

Engineering topics

Joki, E. G.

Publications and source records attributed to Joki, E. G..

A multilayer X-ray mirror for solar photometric imaging flown on a sounding rocket

The flight of a multilayer-coated mirror on a sounding rocket experiment on March 17, 1988 which was used to obtain photometric images of the sun just prior to solar eclipse is discussed. The rocket payload and the choice of passband are described. The design of the multilayer, the fabrication of the mirror, and the reflectance measurements are addressed.

Haisch, B. M.

Lacquer polishing of X-ray optics

Techniques for polishing figured X-ray optics by a lacquer-coating process are described. This acrylic lacquer coating has been applied with an optical quality of an eighth-wave in red light and very effectively covers surface roughness with spatial wavelengths less than about 0.2 mm. Tungsten films have been deposited on the lacquer coatings to provide highly efficient X-ray reflectivity.

Catura, R. C.

Fabrication of imaging X-ray optics

The design, fabrication, and performance of optics for X-ray astronomy and laboratory applications are described and illustrated with diagrams, drawings, graphs, photographs, and sample images. Particular attention is given to the Wolter I telescope developed for spectroscopic observation of 8-30-A cosmic X-ray sources from a rocketborne X-ray Objective Grating Spectrometer; this instrument employs three nested paraboloid-hyperboloid mirrors of 5083 Al alloy, figured by diamond turning and covered with a thin coating of acrylic lacquer prior to deposition of a 40-nm-thick layer of Sn. In calibration tests at NASA Marshall, the FWHM of the line-spread function at 1.33 nm was found to be 240 microns, corresponding to 21 arcsec. Also presented are the results of reflectivity measurements on C and W multilayers sputtered on Si and fusion glass substrates.

Catura, R. C.

Optics for X-ray astronomy

This paper describes a large grazing incidence X-ray telescope that is being prepared for use in a spectrometer for X-ray astronomical observations. The telescope is figured by diamond turning and polished by applying an acrylic lacquer that is overcoated by a thin film of tungsten to provide high X-ray reflectivity. The current status of our research in multilayer deposition is presented and some astronomical applications of multilayer mirrors are described.

Catura, R. C.

Normal incidence multilayer mirrors for extreme ultraviolet astronomy

Sputtered multilayer coatings allow the use of normal incidence optics in the extreme ultraviolet (EUV) region below 500 A. Multilayer mirrors can be tailored to provide images at strong EUV lines in the sun and stars, in many cases making more efficient use of the telescope aperture than grazing incidence optics. Alternatively, the bandpass can be broadened at the expense of peak effective area, by varying the multilayer structure over the mirror surface. Such mirrors can also serve as optical elements in spectrographs for investigation of specific emission and absorption line complexes, and are self-filtering in that they reject nearby geocoronal and cosmic resonance line backgrounds. Current efforts at the Lockheed Palo Alto Research Laboratory in the design, fabrication, and testing of EUV multilayer mirrors are discussed. This program includes the design and fabrication of normal incidence EUV multilayer mirrors, and the deposition of multilayers on lacquer-coated substrates.

Stern, R. A.

Calculated performance of a Wolter type I X-ray telescope coated by multilayers

Deposition of multilayered diffraction coatings on the reflecting surfaces of a Wolter type I X-ray telescope offers the potential of using Bragg reflection to achieve enhanced effective area in selected high energy bandpasses. The structure of a gold-carbon multilayer has been optimized for study of 1.8 A iron-line emission with an X-ray telescope designed for observations from Spacelab. The response of this mirror assembly has been calculated as a function of X-ray energy and the resulting effective area is enhanced by a factor of 10 and peaks at 160 sq cm with a bandpass of 0.4 keV FWHM. This enhanced response is sufficient to allow study of the angular distribution of iron-line emission from the 20 brightest cluster X-ray sources during a 7 day Spacelab mission. The possibility of achieving X-ray imaging in narrow bandpasses at even higher energies has been investigated. It is concluded that it should be possible to achieve effective areas of approximately 5 sq cm in bandpasses approximately 1 keV wide for energies in the 15-25 keV range, a spectral region of much importance during the impulsive phase of solar flares.

Catura, R. C.

A Wolter type I LAMAR

Observational objectives for the LAMAR and their influence on the instrument design are discussed. It is concluded that the most important design parameter is the angular resolution of the LAMAR modules since it so strongly influences sensitivity, optical identifications, source confusion, spectral resolution for objective gratings and the ability to resolve small extended sources. A high resolution Wolter Type I LAMAR module is described, its hardware status discussed, and the performance of a LAMAR observatory presented. A promising technique for enhancing the reflectivity of Wolter Type I X-ray optics in a selected bandpass at high energy has been investigated and the performance of the LAMAR module, utilizing this method, has been calculated.

Catura, R. C.

X-ray line widths and coronal heating

Preliminary results of spectroscopy and imaging of a solar active region and flare plasma in soft X-ray emission lines are presented. Observed X-ray line widths in a nonflaring active region are broader than the Doppler width corresponding to the local electron temperature. An analysis of 41 soft X-ray flares within a single active region reveals a preference for flares to occur at locations that already show enhanced X-ray emission and to favor magnetic complexity over high gradient. However, flares do not appear to be directly responsible for the heating and X-ray production of the active regions.

Acton, L. W.

Large-aperture high-resolution X-ray collimator for the Solar Maximum Mission

A description is presented of a flight-qualified large-aperture 12 x 12-arcsec angular resolution multigrid X-ray collimator developed for the Solar Maximum Mission (SMM) flat crystal spectrometer. This collimator, designed for the 1.4-22.4-A wavelength range, utilizes an optical bench/metering structure to align and support prealigned grid subassemblies. The optical bench is a lightweight, rigid, and stable aluminum honeycomb structure. The grids are of a compound and bimetallic design, having 63.5-micron square holes on an 88.9-micron spacing in 8-micron thick gold, which is in turn supported by a 76-micron thick Invar grid having 600-micron square holes on a 739-micron spacing. The small apertures in the gold provide the 12-arcsec collimation with the Invar grids providing wide angle off-axis blocking out to an approximately 35 arcmin view angle. The collimator has seven individual channels, four of a 5.1- x 10-cm area and three of a 1.3- x 10-cm area. Laboratory measurements gave an average angular resolution of 12.5 arcsec FWHM with 0.259 transmission for the large-area channels and 12.0 arcsec and 0.200 transmission for the small-area channels. A thermal filter composed of two layers of approximately 1000-A thick aluminum prevents solar heating of the front collimator grids by absorbing longer wavelength radiation while passing most of the X radiation in the band of interest.

Nobles, R. A.

Demand-type gas supply system for rocket borne thin-window proportional counters

A simple closed loop control system has been developed to maintain the gas pressure in thin-window proportional counters during rocket flights. This system permits convenient external control of detector pressure and system flushing rate. The control system is activated at launch with the sealing of a reference volume at the existing system pressure. Inflight control to plus or minus 2 torr at a working pressure of 760 torr has been achieved on six rocket flights.

Acton, L. W.

Bent crystal spectrometer for solar X-ray spectroscopy

A bent crystal spectrometer employs a collimated beam of X-rays incident on the crystal over a range of Bragg angles determined by the orientation and curvature of the crystal surface. It provides continuous and simultaneous coverage of all X-ray wavelengths within its spectral range. In-flight testing for solar X-ray spectroscopy was performed using a small instrument to supplement the wavelength coverage of several scanning spectrometers used to study solar active regions in the 9-24 A range. Later testing included modifications to alleviate problems caused by ultraviolet radiation. Future usage of the device will include studies of time variable emission from solar flares or discrete galactic X-ray sources, and the first major experiment to utilize bent crystal spectrometers will be the Solar Maximum Mission satellite in 1979.

Rapley, C. G.

Design and fabrication of multigrid X-ray collimators

The paper considers the design and fabrication of multigrid collimators for use in X-ray astronomy. The most important collimator performance criteria are minimum off-band transmission or leakage, and maximum on-band transmission. Lockheed experience with multigrid collimator is summarized: (1) an Oda type with one-dimensional collimation of 1.7 arc minute FWHM and using only the central transmission band, (2) an Oda type with 2 arc minute one-dimensional collimation using up to 27 transmission bands, each separated by 42 arc min. and (3) a modified Parkinson type with two-dimensional collimation of 40 arc sec. Attention is given to grid materials, precision, plating, hole quality, and results of acceptance testing.

Acton, L. W.

Oxygen-to-neon abundance ratio in the solar corona

The oxygen-to-neon abundance ratio in the solar corona is determined to be 4.7 + or - 1.5 on the basis of a relatively model-independent analysis utilizing 25 separate measurements of the O VIII to Ne IX resonance line ratio. The stated uncertainty includes random and possible systematic experimental error in the data but does not include possible error in the calculated flux ratios which have been fitted to the observations. This abundance ratio is smaller than most published results based upon EUV or X-ray observations but is in good agreement with direct measurements of flare cosmic rays.

Acton, L. W.

Solar X-ray spectroscopy with spatial resolution

Preliminary results from a solar X-ray spectroscopic experiment are presented. The data emphasize the nonhomogeneous and multithermal nature of the corona. The oxygen-to-neon abundance ratio in the corona is found to be about 4.7, as derived from the O VIII-to-Ne IX resonance-line photon flux ratio.

Acton, L. W.