Engineering Papers⌕ Search

Engineering topics

Johnston, S.

Publications and source records attributed to Johnston, S..

At least 37 records · Page 2

Radiogenic backgrounds in the NEXT double beta decay experiment

Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity-induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterr\'aneo de Canfranc with xenon depleted in $^{136}$Xe are analyzed to derive a total background rate of (0.84$\pm$0.02) mHz above 1000 keV. The comparison of data samples with and without the use of the radon abatement system demonstrates that the contribution of airborne-Rn is negligible. A radiogenic background model is built upon the extensive radiopurity screening campaign conducted by the NEXT Collaboration. A spectral fit to this model yields the specific contributions of $^{60}$Co, $^{40}$K, $^{214}$Bi and $^{208}$Tl to the total background rate, as well as their location in the detector volumes. The results are used to evaluate the impact of the radiogenic backgrounds in the double beta decay analyses, after the application of topological cuts that reduce the total rate to (0.25$\pm$0.01) mHz. Based on the best-fit background model, the NEXT-White median sensitivity to the two-neutrino double beta decay is found to be 3.5$\sigma$ after 1 year of data taking. The background measurement in a Q$_{\beta\beta}\pm$100 keV energy window validates the best-fit background model also for the neutrinoless double beta decay search with NEXT-100. Only one event is found, while the model expectation is (0.75$\pm$0.12) events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of the event identification capabilities of the NEXT-White detector

In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the data of the NEXT-White detector, the first detector of the NEXT experiment operating underground. Using a \TO\ calibration source to produce signal-like and background-like events with energies near 1.6 MeV, a signal efficiency of $71.6 \pm 1.5_{\textrm{ stat}} \pm 0.3_{\textrm{ sys}} \%$ for a background acceptance of $20.6 \pm 0.4_{\textrm{ stat}} \pm 0.3_{\textrm{ sys}} \%$ is found, in good agreement with Monte Carlo simulations. An extrapolation to the energy region of the neutrinoless double beta decay by means of Monte Carlo simulations is also carried out, and the results obtained show an improvement in background rejection over those obtained at lower energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron drift and longitudinal diffusion in high pressure xenon-helium gas mixtures

We report new measurements of the drift velocity and longitudinal diffusion coefficients of electrons in pure xenon gas and in xenon-helium gas mixtures at 1-9 bar and electric field strengths of 50-300 V/cm. In pure xenon we find excellent agreement with world data at all E/P, for both drift velocity and diffusion coefficients. However, a larger value of the longitudinal diffusion coefficient than theoretical predictions is found at low E/P in pure xenon, below the range of reduced fields usually probed by TPC experiments. A similar effect is observed in xenon-helium gas mixtures at somewhat larger E/P. Drift velocities in xenon-helium mixtures are found to be theoretically well predicted. Although longitudinal diffusion in xenon-helium mixtures is found to be larger than anticipated, extrapolation based on the measured longitudinal diffusion coefficients suggest that the use of helium additives to reduce transverse diffusion in xenon gas remains a promising prospect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring the Structure of the Bound Proton with Deeply Virtual Compton Scattering

In the past two decades, deeply virtual Compton scattering of electrons has been successfully used to advance our knowledge of the partonic structure of the free proton and investigate correlations between the transverse position and the longitudinal momentum of quarks inside the nucleon. Meanwhile, the structure of bound nucleons in nuclei has been studied in inclusive deep-inelastic lepton scattering experiments off nuclear targets, showing a significant difference in longitudinal momentum distribution of quarks inside the bound nucleon, known as the EMC effect. In this work, we report the first beam spin asymmetry (BSA) measurement of exclusive deeply virtual Compton scattering (DVCS) off a proton bound in $^4$He. The data used here were accumulated using a $6$ GeV longitudinally polarized electron beam incident on a pressurized $^4$He gaseous target placed within the CLAS spectrometer in Hall-B at the Thomas Jefferson National Accelerator Facility. Here, the azimuthal angle ($\phi$) dependence of the BSA was studied in a wide range of virtual photon and scattered proton kinematics. The $Q^2$, $x_B$, and t dependencies of the BSA on the bound proton are compared with those on the free proton. In the whole kinematical region of our measurements, the BSA on the bound proton is smaller by 20\% to 40\%, indicating possible medium modification of its partonic structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fingerprints of an orbital-selective Mott phase in the block magnetic state of BaFe 2 Se 3 ladders

Resonant Inelastic X-Ray Scattering (RIXS) experiments on the iron-based ladder BaFe 2 Se 3 unveiled an unexpected two-peak structure associated with local orbital (dd) excitations in a block-type antiferromagnetic phase. A mixed character between correlated band-like and localized excitations was also reported. Here, we use the density matrix renormalization group method to calculate the momentum-resolved charge- and orbital-dynamical response functions of a multi-orbital Hubbard chain. Remarkably, our results qualitatively resemble the BaFe 2 Se 3 RIXS data, while also capturing the presence of long-range magnetic order as found in neutron scattering, only when the model is in an exotic orbital-selective Mott phase (OSMP). In the calculations, the experimentally observed zero-momentum transfer RIXS peaks correspond to excitations between itinerant and Mott insulating orbitals. We provide experimentally testable predictions for the momentum-resolved charge and orbital dynamical structures, which can provide further insight into the OSMP regime of BaFe 2 Se 3 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First Measurements of the Double-Polarization Observables F , P , and H in ω Photoproduction off Transversely Polarized Protons in the N * Resonance Region

First measurements of double-polarization observables in ${\omega}$ photoproduction off the proton are presented here using transverse target polarization and data from the CEBAF Large Acceptance Spectrometer (CLAS) FROST experiment at Jefferson Lab. The beam-target asymmetry $F$ has been measured using circularly polarized, tagged photons in the energy range 1200–2700 MeV, and the beam-target asymmetries $H$ and $P$ have been measured using linearly polarized, tagged photons in the energy range 1200–2000 MeV. These measurements significantly increase the database on polarization observables. The results are included in two partial-wave analyses and reveal significant contributions from several nucleon (${N}^{*}$) resonances. In particular, contributions from new ${N}^{*}$ resonances listed in the Review of Particle Properties are observed, which aid in reaching the goal of mapping out the nucleon resonance spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modified structure of protons and neutrons in correlated pairs

The atomic nucleus is made of protons and neutrons (nucleons), which are themselves composed of quarks and gluons. Understanding how the quark-gluon structure of a nucleon bound in an atomic nucleus is modified by the surrounding nucleons is an outstanding challenge. Although evidence for such modification-known as the EMC effect-was first observed over 35 years ago, there is still no generally accepted explanation for its cause. Recent observations suggest that the EMC effect is related to close-proximity short-range correlated (SRC) nucleon pairs in nuclei. Here we report simultaneous, high-precision measurements of the EMC effect and SRC abundances. We show that EMC data can be explained by a universal modification of the structure of nucleons in neutron-proton SRC pairs and present a data-driven extraction of the corresponding universal modification function. This implies that in heavier nuclei with many more neutrons than protons, each proton is more likely than each neutron to belong to an SRC pair and hence to have distorted quark structure. This universal modification function will be useful for determining the structure of the free neutron and thereby testing quantum chromodynamics symmetry-breaking mechanisms and may help to discriminate between nuclear physics effects and beyond-the-standard-model effects in neutrino experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Identifying a forward-scattering superconductor through pump-probe spectroscopy

Electron-boson scattering that is peaked in the forward direction has been suggested as an essential ingredient for enhanced superconductivity observed in FeSe monolayers. Here, we study the superconducting state of a system dominated by forward scattering in the time domain and contrast its behavior against the standard isotropic BCS case for both s- and d-wave symmetries. An analysis of the electron's dynamics in the pump-driven non-equilibrium state reveals that the superconducting order in the forward-focused case is robust and persistent against the pump-induced perturbations. The superconducting order parameter also exhibits a non-uniform melting in momentum space. We show that this behavior is in sharp contrast to the isotropic interaction case and propose that time-resolved approaches are a potentially powerful tool to differentiate the nature of the dominant coupling in correlated materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electroluminescence TPCs at the thermal diffusion limit

Here, the NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the ${}^{136}$Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO${}_{2}$, CH${}_{4}$ and CF${}_{4}$) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/$\sqrt{\mathrm{m}}$ for pure xenon down to 2.5 mm/$\sqrt{\mathrm{m}}$ using additive concentrations of about 0.05%, 0.2% and 0.02% for CO${}_{2}$, CH${}_{4}$ and CF${}_{4}$, respectively. Our results show that CF${}_{4}$ admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH${}_{4}$ presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO${}_{2}$ and CH${}_{4}$ show potential as molecular additives in a large xenon TPC, CH${}_{4}$ showing the best performance and stability to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decoupling carrier concentration and electron-phonon coupling in oxide heterostructures observed with resonant inelastic x-ray scattering

In this paper, we report the observation of multiple phonon satellite features in ultra thin superlattices of form n SrIrO 3 / m SrTiO 3 using resonant inelastic x-ray scattering. As the values of n and m vary the energy loss spectra show a systematic evolution in the relative intensity of the phonon satellites. Using a closed-form solution for the RIXS cross section, we extract the variation in the electron-phonon coupling strength as a function of n and m . Combined with the negligible carrier doping into the SrTiO 3 layers, these results indicate that tuning of the electron-phonon coupling can be effectively decoupled from doping. In conclusion, this work showcases both a feasible method to extract the electron-phonon coupling in superlattices and unveils a potential route for tuning this coupling which is often associated with superconductivity in SrTiO 3 -based systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The NEXT White (NEW) detector

Conceived to host 5 kg of xenon at a pressure of 15 bar in the fiducial volume, the NEXT-White apparatus is currently the largest high pressure xenon gas TPC using electroluminescent amplification in the world. It is also a 1:2 scale model of the NEXT-100 detector for 136 Xe ββ0ν decay searches, scheduled to start operations in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas purity needed to guarantee a long electron lifetime. NEXT-White has been operating since October 2016 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. This paper describes the detector and associated infrastructures, as well as the main aspects of its initial operation.

47 OTHER INSTRUMENTATION↗

Beam-target helicity asymmetry E in K 0 Λ and K 0 Σ 0 photoproduction on the neutron

Here, we report the first measurements of the $E$ beam-target helicity asymmetry for the $\vec{\gamma} \vec{n} \to K^{0}\Lambda$, and $K^{0}\Sigma^{0}$ channels in the energy range of 1.70$\leq W\leq$2.34 GeV. The CLAS system at Jefferson Lab used a circularly polarized photon beam and a target consisting of longitudinally polarized solid molecular hydrogen deuteride (HD) with low background contamination for the measurements. Comparisons with predictions from the KaonMAID, SAID, and Bonn-Gatchina models are presented. These results will help separate the isospin $I=0$ and $I=1$ photo-coupling transition amplitudes in pseudoscalar meson photoproduction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of radon-induced backgrounds in the NEXT double beta decay experiment

Here, the measurement of the internal $^{222}$Rn activity in the NEXT-White detector during the so-called Run-II period with $^{136}$Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by $^{222}$Rn and its alpha-emitting progeny. The specific activity is measured to be $(38.1\pm 2.2~\mathrm{(stat.)}\pm 5.9~\mathrm{(syst.)})$~mBq/m$^3$. Radon-induced electrons have also been characterized from the decay of the $^{214}$Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgrounds are sufficiently low to enable a successful NEXT-100 physics program, as the projected rate contribution should not exceed 0.1~counts/yr in the neutrinoless double beta decay sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the NEXT-White detector using 83m Kr decays

We report the NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. It has been operating at Laboratorio Subterraneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed using 83m Kr decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event transverse position which is caused by variations in solid angle coverage both for direct and reflected light and edge effects. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.553 +/- 0.010 (stat.) ± 0.324 (sys.)) % FWHM in the full chamber and (3.804 ± 0.013 (stat.) ± 0.112 (sys.)) % FWHM in a restricted fiducial volume. Laslty, using naive 1/$ \sqrt{E} $ scaling, these values translate into resolutions of (0.5916 ± 0.0014 (stat.) ± 0.0421 (sys.)) % FWHM and (0.4943 ± 0.0017 (stat.) +/- 0.0146 (sys.)) % FWHM at the Qᵦᵦ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.

47 OTHER INSTRUMENTATION↗