Engineering Papers⌕ Search

Engineering topics

Johnson, Timothy J.

Publications and source records attributed to Johnson, Timothy J..

At least 55 records · Page 3

Infrared Optical Constants from Pressed Pellets of Powders: I. Improved n and k Values of (NH4)(2)SO(4)from Single-Angle Reflectance

In combination with other parameters, the real, n(?), and imaginary, k(?), components of the complex refractive index, = n + ik, can be used to simulate the optical properties of a material in different forms, e.g. its infrared spectra. But obtaining reliable values of the optical constants n/k for solid materials is challenging due to the lack of optical quality specimens, usually crystals, large enough to measure. An alternative to crystals is to press the powder into a uniform disk. We have produced pellets from ammonium sulfate, (NH4)2SO4, powder and derived the pellets’ n and k values via single-angle reflectance using a specular reflectance device in combination with a Fourier transform infrared spectrometer. The single-angle technique measures amplitude of light reflected from the material as a function of wavelength over a wide spectral domain; the optical constants are determined from the reflectance data using the Kramers-Kronig relationship. We investigate several parameters associated with the pellets and pellet formation and their effects upon delivering the most reliable n/k values. Parameters studied include pellet diameter, mass and density (void space), drying, grinding, sieving and particle size in the pellet formation, as well as pressing pressure and duration. Of these parameters, using size-selected mixtures of dried, small (< 100 µm) particles and pressing at = 10 tons for at least 30 minutes were found key to forming highly reflective samples. Comparison to two sets of previous literature n(?) and k(?) values obtained from crystalline (NH4)2SO4 both as crystal reflectance as well as extinction spectra of aerosols measured in a flow tube show reasonable agreement, but suggests the present values, as confirmed from two independent techniques, represent a substantial improvement for n/k values for (NH4)2SO4, also demonstrating promise to measure the optical constants of other materials.

Optical constants, index of refraction, single-ang↗

Modeling thin layers of analytes on substrates for spectral analysis: use of solid/liquid n and k values to model reflectance spectra

Since solids are only sometimes seen en masse in a pure bulk form, and for liquids other than water almost never, a capability to model reflectance spectra from analytes deposited on various substrates would be highly advantageous. If available, the real, n ( ν ) , and imaginary, k ( ν ) , components of the complex refractive index, n n + i k , can be used to simulate infrared spectra, accounting for reflection, refraction, and absorption phenomena as a function of wavelength. We focus on using the Pacific Northwest National Laboratory (PNNL) derived n / k vectors for solid and liquid analytes deposited as thin layers on different types of substrates including conductors, such as aluminum, and inorganic dielectrics, such as glass. The model is an adaptation of the Monte Carlo ray trace modeling program, TracePro, extended through the use of its macrolanguage. The model is tested using thin films of organic liquids including silicone oil and no. 2 diesel fuel, as well as organic solids such as caffeine and acetaminophen on aluminum and glass. The predicted spectra for the solid films were compared to experimental hemispherical reflectance data measured using a Fourier transform spectrometer with an integrating sphere. The thickness of the calculated layer is a parameter for predicting the (transflectance) spectra and is obtained using the areal density measured from gravimetric methods to generate the thin-layer samples. Comparison of the calculated spectra with experimental hemispherical reflectance data shows excellent agreement, indicating promise for the use of measured n / k data to synthesize reference spectral data. In particular, accounting for the inhomogeneity of the deposits greatly improved the match with experimental data. Finally, the theoretical modeling shows that for thicker layers (ca. 20 to 100 μm) of typical organics possessing moderately strong k values, the longwave infrared features are often saturated and better spectral contrast is obtained from the overtone/combination bands in the shortwave infrared.

42 ENGINEERING↗

Quantitative far-infrared band strengths of iodine monochloride (ICl), a molten salt off-gas product

The gaseous (by)products generated from molten salt reactors need to be monitored to prevent the release of potentially toxic gases to the environment. In particular, 129I has a long half-life and its toxicity and persistence in the environment make iodine and iodine-containing compounds (such as ICl from chloride containing molten salt systems) of great concern. Optical spectroscopy tools, including Raman and Fourier-transform infrared (FTIR) spectroscopies, are ideal for monitoring and quantifying such off-gas products. Iodine (I2) has a strong and distinct Raman signature and the change in signal with a change in concentration can be used for quantification of these byproducts. Iodine monochloride (ICl) has distinct signatures in both the Raman and the infrared, and its spectrum can also potentially be used for quantitative measurement of this species. In this paper we discuss our recent results on the quantification of iodine monochloride using infrared spectroscopy, in particular first reports of the absolute infrared band strength of ICl.

infrared (IR) spectroscopy, Molten Salt Reactors, ↗

Impact of pellet preparation on reflectance measurements of ammonium sulfate by single-angle reflectance spectroscopy

The optical constants, n and k, are required to model the reflection, refraction and transmission of light at the first surface interface of a material, as well as its propagation through the material; here n corresponds to the real component and k the imaginary component of the refractive index. Several different spectroscopic methods have been used to determine the n and k values for different materials, including single angle reflectance spectroscopy and ellipsometry. The single-angle reflectance method quantitatively records the specular reflectance R(v) from a plane parallel face of the material and uses the Kramers-Kronig transform to extract the n and k values. For most compounds, however, it is difficult to obtain a single crystal or high-quality window of sufficient planarity and of the appropriate dimensions (several mm) to make the measurement. For this reason, we further investigate the use of pressed pellets of neat powdered substances to measure optical constants of these substances using the single-angle reflectance method. We have found that surface roughness can significantly influence the measured quantitative reflectance spectrum R(v) and, consequently, the derived n and k parameters. A collaborative study between Defence Research and Development Canada (DRDC) - Valcartier Research Center and Pacific Northwest National Laboratory (PNNL) has been carried out using different pellets of neat ammonium sulfate [(NH4)2SO4] to show how parameters such as the relative fraction of particle sizes for the component powder along with the grinding process of the pure compound all can affect the reflectance spectrum used to derive the optical constants. All pressed pellets were characterized by single-angle reflectance spectroscopy.

Diaz, Emmanuela↗

Analyzing Wildland Fire Smoke Emissions Data Using Compositional Data Techniques

By conservation of mass, the mass of wildland fuel that is pyrolyzed and combusted must equal the mass of smoke emissions, residual char and ash. For a given set of conditions, these amounts are fixed. This places a constraint on smoke emissions data which violates statistical assumptions for many of the methods currently used to analyze these data such as linear regression, analysis of variance, and t-tests. These data are inherently multivariate and non-negative parts of a whole. This paper introduces the field of compositional data analysis to the emissions community and provides examples of appropriate statistical treatment of emissions data. It is shown that modified combustion efficiency should not be used as a predictor variable for other smoke emissions because it is not an independent variable. An alternative method based on compositional linear trends to estimate trace gas composition using CO and CO2 is presented. The data used in this paper resulted from projects the DOD/DOE/EPA Strategic 586 Environmental Research and Development Program projects RC-1648 and 1649. The senior 587 author appreciates the guidance and R scripts provided by Prof. Girty at San Diego State 588 University to estimate linear trends by perturbation. J. P.-A. was supported by the Spanish 589 Ministry of Science, Innovation and Universities under the project CODAMET (RTI2018-590 095518-B-C21, 2019-2021). The data used in this study have been previously published and are 591 available in the original publications. DRW conceived the initial manuscript (70 percent) and 592 performed the bulk of the data analysis. JPA provided statistical guidance and compositional data 593 expertise and contributed 20 percent of the manuscript. TJJ and HJ were extensively involved in 594 the study that provided the data. TJJ provide smoke emissions expertise and HJ provided 595 combustion expertise. The authors declare that they have no conflict of interest. The use of trade 596 or firm names in this publication is for reader information and does not imply endorsement by 597 the U.S. Department of Agriculture of any product or service.

simplex, compositional data analysis, balance, log↗

In-situ measurement of pyrolysis and combustion gases from biomass burning using swept wavelength external cavity quantum cascade lasers

Broadband high-speed absorption spectroscopy using swept-wavelength external cavity quantum cascade lasers (ECQCLs) is applied to measure multiple pyrolysis and combustion gases in biomass burning experiments. Two broadly-tunable swept-ECQCL systems were used, with the first tuned over a range of 2089-2262 cm -1 (4.42 – 4.79 µm) to measure spectra of CO 2 , H 2 O, and CO. The second was tuned over a range of 920-1150 cm -1 (8.70 – 10.9 µm) to measure spectra of ammonia (NH 3 ), ethene (C 2 H 4 ), and methanol (MeOH). Absorption spectra were measured continuously at a 100 Hz rate throughout the burn process, including inhomogeneous flame regions, and analyzed to determine time-resolved gas concentrations and temperature. The results provide in-situ, dynamic information regarding gas-phase species as they are generated, close to the biomass fuel source.

09 BIOMASS FUELS↗

Hyperspectral imaging of minerals in the longwave infrared: the use of laboratory directional-hemispherical reference measurements for field exploration data

Hyperspectral Imaging (HSI) continues to grow as a method for remote detection of vegetation, materials, minerals, and pure chemicals. We have used a longwave infrared (7.7 - 11.8 µm) imaging spectrometer in a static outdoor experiment to collect HSI data from 24 minerals and background materials to determine the efficacy with which HSI can remotely detect and distinguish both pure minerals and mineral mixtures at three solar angles (25°, 35°, and 45° relative to ground) as well as varying backgrounds and other sample effects. Measurements were obtained separately for the minerals and materials mounted directly both on a bare plywood board and a plywood board coated with aluminum foil: 19 powders (3 mixtures and 16 pure mineral powders) held in polyethylene bottle lids as well as 5 samples in rock form were taped directly to the boards. The primary goal of the experiment was to demonstrate that a longwave infrared (LWIR) library of solids and minerals collected as directional-hemispherical reflectance spectra in the laboratory can be used directly for HSI field identification. Prior to the experiment, all 24 mineral/inorganic samples were measured in the laboratory using a Fourier transform infrared spectrometer (FTIR) equipped with a gold-coated IR integrating sphere; the spectra were assimilated as part of a larger reference library of 21 pure minerals, 3 mixtures, and the polyethylene lid. Principal components analysis (PCA) with mean-centering was used in an exploratory analysis of the HSI images and showed that for the aluminum coated board, the first principal component captured the difference between signal that resembled a blackbody and the highly reflective aluminum background. In contrast, principal components PC 2, 3, and 4 were able to discriminate the materials including phosphates, sulfates, silicates, carbonates, and the mixtures. Results from generalized least squares target detection clearly showed that laboratory reference spectra of minerals could be utilized as targets with high fidelity for field detection, both for pure and mixed samples.

47 OTHER INSTRUMENTATION↗

Gas-phase pyrolysis products emitted by prescribed fires in pine forests with a shrub understory in the southeastern United States

Here we confirm pyrolysis gases from prescribed burns conducted inpine forests with a shrub understory captured using a manual extraction device. The device selectively sampled emissions ahead of the flame front,minimizing the collection of oxidized gases, with the captured gases analyzed in the laboratory using infrared (IR) absorption spectroscopy. Results show that emission ratios (ERs) relative to CO for ethene and acetylene were significantly greater than in previous fire studies, suggesting that the sample device was able to collect gases predominantly generated prior to ignition. Additional evidence that ignition had not begun was corroborated by novel IR detections of several species, in particular naphthalene. With regards to oxygenated species, several aldehydes (acrolein, furaldehyde, acetaldehyde,formaldehyde) and carboxylic acids (formic, acetic) were all observed;results show that ERs for acetaldehyde were noticeably greater, while ERs for formaldehyde and acetic acid were lower compared to other studies. The acetylene-to-furan ratio also suggests that high-temperature pyrolysis was the dominant process generating the collected gases.

54 ENVIRONMENTAL SCIENCES↗

A Free Spectroscopic Databank of Optical Constants for Use in Optics Education and Modeling: complex refractive index data n and k from 1.0 to 25 um

The reflectance spectra of solid and liquids can be complicated since they depend not only on absorption, but also on the refraction, reflection, and scattering of light, all of which are wavelength dependent. The physical form and morphological effects associated with solid and liquid samples are thus known to affect their reflectance spectra in a non-linear fashion, particularly in the infrared. Measuring the optical constants n(?) and k(?) represents an alternative approach, allowing one to model these many effects and thus requiring fewer laboratory measurements. In this paper an overview is presented of the protocols used to measure the n/k optical constants, particularly for liquids. For the liquids, a multiple path length measurements approach is employed, and in this paper we demonstrate the method to determine the complex optical constants n(?) and k(?) of squalene. The resultant calculated spectra of 1 µm and 100 µm thick layers of squalene on an aluminum substrate as derived from the experimental n(?) and k(?) values are shown to demonstrate such effects. The public availability of the n(?)/k(?) data as well as solids hemispherical reflectance data are also discussed.

optical constants, refractive index, solids, Liqui↗

Obtaining the complex optical constants n and k via quantitative absorption measurements in KBr pellets

Reflectance (emittance) spectroscopy, especially at infrared wavelengths, continues to grow in utility as an analytical technique for contact, standoff, and remote sensing. The reflectance spectra of solids, however, are complex, depending on many parameters, even for the same material. Granule or powder particle size, crystal morphology, layer thickness, and substrate material all affect the spectral distribution of reflected light. However, such phenomena can all be modeled if the optical constants n(?) and k(?) are available. If the quantitative absorption coefficient K(?) is known, the k value can be obtained via the relation k(?) = 2.303K(?)/4p?. The absorption coefficient can in turn be derived from a simple KBr-pellet infrared absorption measurement, provided the pellet mass ratio is prepared quantitatively. The method requires the pellet’s mass and diameter, along with the analyte mass fraction and density. In this paper we demonstrate the requisite experimental details in preparing the pellets, as well as methods to reduce light scattering in order to obtain more quantitative values. Theoretical methods to derive the related optical constants will also be detailed, in particular the assumptions used to obtain the scalar refractive index n. Ideally, this value is known or measured separately, but in some cases we have found that it can be approximated (first approximation) for most organic chemicals by n~1.5 at the shortest wavelength. The results are presented for a couple of species.

optical constants, solids, KBr pellet↗

Fixed-Angle Reflectance from Uranium Compounds and U-Bearing Minerals: Experimental Challenges to Determine the Optical Constants n and k

Fixed-angle reflectance spectroscopy using a commercial Fourier transform infrared (FTIR) spectrometer was employed to derive the optical constants n and k of several uranium compounds. This technique relies upon measurement of the quantitative reflectance R(?) spectra from a polished surface across a broad spectral range (in this case, the mid- and far-IR covering ca. 7500 to 50 cm-1) followed by application of the Kramers-Kronig transformation (KKT). Near-normal fixed-angle measurements as used in this technique require continuous reflectance spectra to as low a wavenumber value as possible. Here, we discuss some of the many challenges in measuring the far-IR and very far-IR (terahertz) spectra using an interferometric instrument, particularly those stemming from small sample sizes, typically just millimeters on a face for crystalline samples, as well as limitations due to optical components and diffraction. We apply this method to single-crystal UO2 and its mineralogical form uraninite, as well as other U-bearing minerals such as autunite [Ca(UO2)2(PO4)2·8-12H2O] and the dehydrated form of autunite, meta-autunite. In addition to the specular reflectance spectra, x-ray diffractometry was used as a confirmatory technique to analyze the surface composition of the species. Deriving the infrared optical constants for such U-bearing species (as well as other solids) will enable nondestructive detection under a variety of environmental and compositional conditions.

Uranium Minerals, infrared spectroscopy, optical c↗

Accurate Optical Constants for Liquids in the Near-Infrared: Improved Methods for Obtaining the n and k Constants from 1 to 4 Microns

Other than open bodies of water, bulk liquids are rarely encountered in the environment. Rather, liquids are typically found as aerosols, liquid droplets, or liquid layers on sundry substrates: glass, concrete, metals, etc. The layers can be of varying thicknesses, from micron-level to millimeter thick deposits. The infrared (IR) reflectance spectra of such deposits vary greatly, approximating the bulk reflectance for thicker deposits and for thinner layers on reflective surfaces, producing “transflectance” spectra that more closely replicate simple transmission of the IR light twice traversing the absorptive medium. Rather than recording large numbers of such spectra to serve as endmembers of a spectral reflectance library, we have recognized that the spectra can be modeled so long as the complex optical constants n(?) and k(?) are known as a function of frequency, ?. Here n is the real (dispersion) part and k is the imaginary (absorption) component of the complex index of refraction. However, in many cases the bands in the longwave IR (7 to 13 µm) can become saturated, and better signal-to-noise and specificity can be realized at shorter wavelengths. In earlier studies, we obtained the n/k values from 1.28 to 25 µm for a series of liquids, but are now expanding those measurements to include additional liquid species and extending the spectral range to lower wavelengths. In this paper we describe the methodologies for compiling and fusing the two data sets collected to provide better and more complete spectral coverage from 1 to 25 µm (10,000 to 400 cm-1). The broad spectral range means that one needs to account for both strong and weak spectral features, all of which can be useful for detection, depending on the scenario. To account for the large dynamic range, both long and short path length transmission cells are required for accurate measurements.

optical constants, refractive index, liquids, mid ↗

Identification of gas-phase pyrolysis products in a prescribed fire: first detections using infrared spectroscopy for naphthalene, methyl nitrite, allene, acrolein and acetaldehyde

Volatile organic compounds (VOCs) are emitted from many sources, includingwildland fire. VOCs have received heightened emphasis due to such gases'influential role in the atmosphere, as well as possible health effects. Wehave used extractive infrared (IR) spectroscopy on recent prescribed burnsin longleaf pine stands and herein report the first detection of fivecompounds using this technique. The newly reported IR detections includenaphthalene, methyl nitrite, allene, acrolein and acetaldehyde. We discussthe approaches used for detection, particularly the software methods neededto fit the analyte and multiple (interfering) spectral components within theselected spectral micro-window(s). We also discuss the method's detectionlimits and related parameters such as spectral resolution.

54 ENVIRONMENTAL SCIENCES↗

Optical and Chemical Characterization of Uranium Dioxide (UO 2 ) and Uraninite Mineral: Calculation of the Fundamental Optical Constants

Quantitative infrared single-angle reflectance spectroscopic measurements using a calibrated Fourier transform infrared spectrometer were performed on synthetic uranium dioxide (UO2), high-purity crystalline uraninite, and massive uraninite mineral. The massive uraninite mineral was found to contain not only UO2 but also large amounts of calcite and silicates. From the experimentally measured reflectance spectra across two spectral domains (the far- and mid-infrared) the fundamental optical constants n and k were calculated using the Kramers-Kronig transformation for each species. We discuss both the derived n and k results for these species as well as the careful sample preparation needed in order to mount, polish, and measure such samples through a wide spectral range using modern instrumentation and data processing techniques. Our results for the optical constants n and k of synthetic UO2 differ significantly from previously published literature values. This is attributed to both improved spectroscopic resolution but also to a better understanding of potential surface oxidation effects on the measured reflectance values, and hence the calculated optical constants.

DeVetter, Brent M.↗

Modeling liquid organic thin films on substrates

We present the rationale, methods, and results of modeling of thin film organic liquids on various substrates. These liquids may coat surfaces (substrates) either as a result of their production, dispersal via aerosols or spills. Identification of unknown coated surfaces using either reflectance or emittance spectroscopy cannot be accomplished simply through reference to reflectance signature libraries since neither the thickness of the liquid layer nor the substrate type is known beforehand and both contribute to the signature. Liquid spectral libraries offer the complex index of refraction (n,k) as a function of wavelength which by itself is useful only for thick (bulk) liquid layers via computation of reflectance and transmittance coefficients using the Fresnel equations. Thin liquid layers both reflect and refract incident light in combination with reflectance from the substrate. We show modeling of various organic liquids on substrates using commercial thin film design and modeling software, as well as Monte Carlo ray tracing software to demonstrate the variety of potential signatures encountered that depend on the thickness of the liquid layer as well as the characteristics of the substrate (metal or dielectric). These substrates give rise to transflectance behavior, while many dielectric substrates have rich absorption features that provide complex signatures that combine attributes of both the liquid and the substrate. Knowledge of the complex index of refraction of both target liquids and substrates is essential in order to synthesize spectra necessary in the application of target identification algorithms.

complex index of refraction↗

Accurate Measurement of the Optical Constants for Organic and Organophosphorous Liquid Layers and Drops

We present accurate measurements for the determination of the optical constants for a series of organic liquids, including organophosphorous compounds. Bulk liquids are rarely encountered in the environment, but more commonly are present as droplets of liquids or thin layers on various substrates. Providing reference spectra to account for the plethora of morphological conditions that may be encountered under different scenarios is a challenge. An alternative approach is to provide the complex optical constants, n and k, which can be used to model the optical phenomena in media and at interfaces, minimizing the need for a vast number of laboratory measurements. In this work, we present improved protocols for measuring the optical constants for a series of liquids that span the range from 7800 to 400 cm-1. The broad spectral range means that one needs to account for both the strong and weak spectral features that are encountered, all of which can be useful for detection, depending on the scenario. To span this dynamic range, both long and short cells are required for accurate measurements. The protocols are presented along with experimental and modeling results for thin layers of silicone oil on aluminum.

optical constants↗

Characterization of Uranium Ore Concentrate Chemical Composition via Raman Spectroscopy

Uranium Ore Concentrate (UOC, often called yellowcake) is a generic term that describes the initial product resulting from the mining and subsequent milling of uranium ores en route to production of the U-compounds used in the fuel cycle. Depending on the mine, the ore, the chemical process, and the treatment parameters, UOC composition can vary greatly. With the recent advent of handheld spectrometers, we have chosen to investigate whether either commercial off-the-shelf (COTS) handheld devices or laboratory-grade Raman instruments might be able to i) identify UOC materials, and ii) differentiate UOC samples based on chemical composition and thus suggest the mining or milling process. Twenty-eight UOC samples were analyzed via FT-Raman spectroscopy using both 1064 nm and 785 nm excitation wavelengths. These data were also compared with results from a newly developed handheld COTS Raman spectrometer using a technique that lowers background fluorescence signal. Initial chemometric analysis was able to differentiate UOC samples based on mine location. Additional compositional information was obtained from the samples by performing XRD analysis on a subset of samples. The compositional information was integrated with chemometric analysis of the spectroscopic dataset allowing confirmation that class identification is possible based on compositional differences between the UOC samples, typically involving species such as U3O8, α-UO2(OH)2, UO4•2H2O (metastudtite), K(UO2)2O3, etc. While there are clearly excitation λ sensitivities, especially for dark samples, Raman analysis coupled with chemometric data treatment can nicely differentiate UOC samples based on composition and even mine origin.

Su, Yin-Fong↗