Engineering Papers⌕ Search

Engineering topics

Johnson, Timothy J

Publications and source records attributed to Johnson, Timothy J.

At least 19 records

SERDP PFAS 2.0 - An infrared spectral database for gas-phase quantitation of volatile per- and polyfluoroalkyl substances (PFAS)

We report the construction of a database of vetted infrared spectra specifically targeting volatile fluorocarbon gases that may be emitted during thermal treatment of per- and polyfluoroalkyl substances (PFAS) to assist understanding of treatment processes and improve quantification. To populate this database, protocols derived from the Pacific Northwest National Laboratory (PNNL) infrared spectral database are used, curtailing the species selection for this data set. Each spectrum in the database is a weighted average derived from 10 or more individual measurements at different partial pressures (static method) or flow rates (dissemination method) to yield good fidelity of both strong and weak infrared signatures, with each composite spectrum ranging from = 6500 cm-1 to = 600 cm-1 with an apodized resolution of 0.112 cm-1. This resolution was chosen to fully resolve all spectral features, recognizing that atmospheric pressure broadening results in nearly all ro-vibrational lines having linewidths = 0.1 cm-1. As an example case, application of the database is demonstrated via identification and quantification of dominant 1H-perfluoroheptane and perfluorohept-1-ene fluorocarbon products resulting from thermal decomposition of perfluorooctanoate (PFOA) below 450 °C.

Infrared, Gas-phase spectra, FTIR, Spectral databa↗

SERDP PFAS Database

The PNNL-PFAS database was constructed to provide quantitative infrared spectra of per- and polyfluoroalkyl substances (PFAS) in the gas phase. These fluorine-rich, organic compounds have been used as non-flammable solvents, cleaning agents, and in the manufacture of a diverse variety of consumer products. Due to their widespread use and relative inertness, PFAS have accumulated in the natural environment, and exposure to these chemicals may be linked to harmful health effects. Development of methods for detecting and remediating PFAS contamination are thus active areas of research. This database supports PFAS investigations where gas-phase infrared signatures may be measured (e.g., during treatment by thermal decomposition). The database currently contains infrared spectra for 15 compounds; these were selected based on the potential of these compounds being thermal degradation products of the manufactured chemicals mentioned above. • Additional compounds will be added to the database in the future. • Additional information about the database may be obtained from [link to future paper about the PFAS database].

PFAS, infrared(IR)spectroscopy, DATABASE, FTIR, sp↗

Investigation of the Polymorphs and Hydrolysis of Uranium Trioxide

This work focuses on progress in gaining a better understanding of the polymorphic nature of the UO3-water system, one of several important materials associated with the nuclear fuel cycle. The UO3-water system is complex and has not been fully characterized, even though these species are common throughout the fuel cycle. Powder x-ray diffraction, Raman and fluorescence characterization was performed on polymorphic forms of UO3 and UO3 hydrolysis products for the purpose of developing some predictive capability of estimating process history and utility, e.g. for polymorphic phases of unknown origin. Specifically, we have investigated three industrially relevant production pathways of UO3 and discovered a previously unknown low temperature route to β-UO3. Pure phases of UO3, hydrolysis products and starting materials were used to establish optical spectroscopic signatures for these compounds.

Sweet, Lucas E↗

Adapting Raman Spectra from Laboratory Spectrometers to Portable Detection Libraries

Raman spectral data collected with high-resolution laboratory spectrometers are processed into a for- mat suitable for importing as a user library on a 1064nm DeltaNu rst generation, eld-deployable spectrometer prototype. The two laboratory systems used are a 1064nm Bruker spectrometer and a 785nm Kaiser spectrometer. The steps taken to compensate for device-dependent spectral resolution, wavenumber shifts between instruments, and wavenumber sensitivity variation are described.

Weatherall, James↗

Methods and systems for remote detection of gases

Novel systems and methods for remotely detecting at least one constituent of a gas via infrared detection are provided. A system includes at least one extended source of broadband infrared radiation and a spectrally sensitive receiver positioned remotely from the source. The source and the receiver are oriented such that a surface of the source is in the field of view of the receiver. The source includes a heating component thermally coupled to the surface, and the heating component is configured to heat the surface to a temperature above ambient temperature. The receiver is operable to collect spectral infrared absorption data representative of a gas present between the source and the receiver. The invention advantageously overcomes significant difficulties associated with active infrared detection techniques known in the art, and provides an infrared detection technique with a much greater sensitivity than passive infrared detection techniques known in the art.

47 OTHER INSTRUMENTATION↗

Challenges of infrared reflective spectroscopy of solid-phase explosives and chemicals on surfaces

Reliable active and passive hyperspectral imaging and detection of explosives and solid-phase chemical residue on surfaces remains a challenge and an active area of research and development. Both methods rely on reference libraries for material identification, but in many cases the reference spectra do not sufficiently resemble those instrumental signals scattered from real-world objects. We describe a physics-based model using the dispersive complex dielectric constant to explain what is often thought of as anomalous behavior of scattered or non-specular signatures encountered in active and passive sensing of explosives or chemicals on surfaces and show modeling and experimental results for RDX.

hyperspectral imaging, infrared reflective spectro↗

Investigations into the Polymorphs and Hydration Products of UO3

This work focuses on progress in gaining a better understanding of the polymorphic nature of the UO{sub 3} and UO{sub 3}-water system; one of several important materials associated with the nuclear fuel cycle. The UO{sub 3}-water system is complex and has not been fully characterized, even though these species are common throughout the fuel cycle. For example, most production schemes for UO{sub 3} result in a mixture of up to six different polymorphic phases, and small differences in these conditions will affect phase genesis that ultimately results in measureable changes to the end product. Here we summarize our efforts to better characterize the UO{sub 3}-water system with optical techniques for the purpose of developing some predictive capability of estimating process history and utility, e.g. for polymorphic phases of unknown origin. Specifically, we have investigated three industrially relevant production pathways of UO{sub 3} and discovered a previously unknown low temperature route to {beta}-UO{sub 3}. Powder x-ray diffraction and optical spectroscopies were utilized in our characterization of the UO{sub 3}-water system. Pure phases of UO{sub 3}, its hydrolysis products and starting materials were used to establish optical spectroscopic signatures for these compounds. Preliminary aging studies were conducted on the {alpha}- and {gamma}-phases of UO{sub 3}.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Demonstrated Wavelength Portability of Raman Reference Data for Explosives and Chemical Detection

As Raman spectroscopy continues to evolve, questions arise as to the portability of Raman data: dispersive versus Fourier transform, wavelength calibration, intensity calibration, and in particular the frequency of the excitation laser. While concerns about fluorescence arise in the visible or ultraviolet, most modern (portable) systems use near-infrared excitation lasers, and many of these are relatively close in wavelength. We have investigated the possibility of porting reference data sets from one NIR wavelength system to another. We have constructed a reference library consisting of 145 spectra, including 20 explosives, as well as sundry other compounds and materials using a 1064 nm spectrometer. These data were used as a reference library to evaluate the same 145 compounds whose experimental spectra were recorded using a second 785 nm spectrometer. In 128 cases of 145 (or 88.3% including 20/20 for the explosives) the compounds were correctly identified with a mean 'hit score' of 954 of 1000. Adding in criteria for when to declare a correct match versus when to declare uncertainty, the approach was able to correctly categorize 134 out of 145 spectra, giving a 92.4% accuracy. For the few that were incorrectly identified, either the matched spectra were spectroscopically similar to the target or the 785 nm signal was degraded due to fluorescence. The results indicate that imported data recorded at a different NIR wavelength can be successfully used as reference libraries, but key issues must be addressed: The reference data must be of equal or higher resolution, the systems require rigorous wavelength calibration, and wavelength-dependent intensity response should be accounted for in the different systems.

47 OTHER INSTRUMENTATION↗

Raman Database Considerations for Near-Infrared Systems

For Raman spectroscopy the ability to detect is often limited by the existence and quality of the reference library to which field spectra are compared. Developing such databases is often labor- and resource-intensive; typically the generated data are not transferred to other instruments. Still other considerations may exist for comparing data at visible and ultraviolet excitation wavelengths such as resonance enhancement. However, for the common near-infrared wavelengths of 785, 830, 960, 1047 and 1064 nm where this is normally of a lesser concern, it is logical to consider whether data can be ported from one spectrometer to another so as to obviate the expensive and time-consuming process of generating reference data for each system. The present experiment generated a list of 125 chemical and common substances and formed a database from their corresponding 1064 nm spectra. The same molecules were then measured using a 785 nm system the new spectra were treated as “unknowns” and compared to the 1064 nm database using a commercial search algorithm. We found that at least 108 of the 125 spectra recorded at 785 nm were correctly identified using the search algorithm. For the few that were incorrectly identified, in most cases the spectra were extremely similar or the 785 nm signal was degraded due to fluorescence, as would occur regardless of reference data. Our results indicate that if the spectrometers are properly calibrated on both their wavelength and intensity axes, “foreign” data recorded at a different NIR wavelength can be successfully used as reference libraries

Kunkel, Brenda M↗

Airborne and ground-based measurements of the trace gases and particles emitted from prescribed fires in the United States

We measured the emission factors for 19 trace gas species and particulate matter (PM2.5) from 14 prescribed fires in chaparral and oak savanna in the southwestern US, as well as pine forest understory in the southeastern US and Sierra Nevada mountains of California. These are likely the most extensive emission factor field measurements for temperate biomass burning to date and the only published emission factors for temperate oak savanna fuels. This study helps close the gap in emissions data available for temperate zone fires relative to tropical biomass burning. We present the first field measurements of the biomass burning emissions of glycolaldehyde, a possible precursor for aqueous phase secondary organic aerosol formation. We also measured the emissions of phenol, another aqueous phase secondary organic aerosol precursor. Our data confirm previous suggestions that urban deposition can impact the NOx emission factors and thus subsequent plume chemistry. For two fires, we measured the emissions in the convective smoke plume from our airborne platform at the same time the unlofted residual smoldering combustion emissions were measured with our ground-based platform after the flame front passed through. The smoke from residual smoldering combustion was characterized by emission factors for hydrocarbon and oxygenated organic species that were up to ten times higher than in the lofted plume, including significant 1,3-butadiene and isoprene concentrations which were not observed in the lofted plume. This should be considered in modeling the air quality impacts of smoke that disperses at ground level, and we show that the normally-ignored unlofted emissions can also significantly impact estimates of total emissions. Preliminary evidence of large emissions of monoterpenes was seen in the residual smoldering spectra, but we have not yet quantified these emissions. These data should lead to an improved capacity to model the impacts of biomass burning in similar ecosystems.

09 BIOMASS FUELS↗

Infrared Signatures to Discriminate Viability of Autoclaved Bacillus Spores

Optical methods can offer good sensitivity for detecting small amounts of chemicals and biologicals, and as these methods mature, are some of the few techniques that can offer true standoff detection. For detection of biological species, determining the viability is clearly important: Certain species of gram-positive bacteria are capable of forming endospores, specialized structures that arise when living conditions become unfavorable or little growth medium is available, being resistant to many chemicals as well as changes in heat or pH. Such spores can remain dormant from months to years until more favorable conditions arise, resulting in germination back to the vegetative state. This persistence characteristic of bacterial spores allows for contamination of a surface (e.g. food or medical equipment) even after the surface has been nominally cleaned. Bacterial spores have also been used as biological weapons, as in the case with B. anthracis. Thus, rapid analysis to determine a spore's viability in a given environment or after attempts to sterilize a given environment is crucial. The increasing availability of portable spectrometers may provide a key to such rapid onsite analysis. The present study was designed to determine whether infrared spectroscopy may be used to differentiate between viable vs. dead B. subtilis and B. atrophaeus spores. Preliminary results show that the reproducible differences in the IR signatures can be used to identify viable vs. autoclaved (dead) B. subtilis and B. atrophaeus bacterial spores.

Schneider, Matthew D↗

Visible/Near-Infrared Hyperspectral Sensing of Solids under Controlled Environmental Conditions

We describe the use of a wind tunnel for conducting controlled passive hyperspectral imaging experiments. Passive techniques are potentially useful for detecting explosives, solid-phase chemicals and other materials of interest from a distance so as to provide operator safety. The Pacific Northwest National Laboratory operates a wind tunnel facility that can generate and circulate artificial atmospheres to control lighting, humidity, temperature, aerosol burdens, and obscurants. We will present recent results describing optimized sensing of solids over tens of meters distance using both visible and near-infrared cameras, as well as the effects of certain environmental parameters on data retrieval.

99 GENERAL AND MISCELLANEOUS↗

A Prescribed Fire Emission Factors Database for Land Management and Air Quality Applications

The Clean Air Act, its amendments, and air quality regulations require that prescribed fire managers estimate the quantity of emissions that a prescribed fire will produce. Information on emissions is available for these calculations; however, it is often incomplete or difficult to find. Tables and computer models can also provide some of this information, but the quality and applicability of the data to a specific site are unknown. In conjunction with three research projects developing new emissions data and meteorological tools to assist prescribed fire managers, the Resource Conservation and Climate Change Program Area of the Department of Defense's Strategic Environmental Research and Development Program is supporting development of a database that contains emissions information related to prescribed burning. Ultimately the vetted database will be available on the Internet and will contain emissions information that has been developed from laboratory and field-scale measurements and has been published.

Lincoln, Emily↗

Laboratory measurements of trace gas emissions from biomass burning of fuel types from the southeastern and southwestern United States

Fuels commonly managed by prescribed burning were collected from five Department of Defense (DoD) bases in the southeast and southwest U.S. and burned under controlled conditions at the USFS Firelab in Missoula, MT. The smoke emissions were measured with a large suite of state-of-the-art instrumentation. A key instrument used in the measurement of the gas-phase species in smoke was an open-path Fourier transform infrared (OP FTIR) spectrometer. The OP FTIR detected and quantified 19 gas-phase species in these fires - CO2, CO, H2O, NO2, NO, HONO, NH3, HCl, SO2, CH4, CH3OH, HCHO, HCOOH, C2H2, C2H4, CH3COOH, HCN, C3H6 and C4H4O. Of particular interest, gas-phase nitrous acid (HONO) was detected in the smoke from all fires. The HONO emission factor ranged from 0.15 to 0.60 g kg 1 and was higher for the southeast fuels. Similarly, the fire-integrated molar emission ratios (relative to NOx) ranged from approximately 0.03 to 0.20, with higher values observed for the southeast fuels. HONO is an important precursor in the production of OH, the primary oxidizing species in the atmosphere but there exists little previous data documenting HONO emissions from either wild or prescribed fires. The detected non-methane organic compound (NMOC) emissions were dominated by oxygenated volatile organic compounds (OVOCs) with total identified molar OVOC emissions ranging from 39 to 79% of the total identified molar non-methane organic compounds (NMOC). Emitted NMOC can undergo further oxidation and photolysis in the case of OVOC and thus involved in secondary aerosol formation. Elevated amounts of gas-phase HCl and SO2 were also detected in the smoke, with the amounts varying depending on location and vegetation type. Emission factors for HCl were typically much higher for the southwest fuels, particularly those found in the chaparral biome in the coastal regions of California.

09 BIOMASS FUELS↗

Visible Hyperspectral Imaging for Standoff Detection of Explosives on Surfaces

There is an ever-increasing need to be able to detect the presence of explosives, preferably from standoff distances. This paper presents an application of visible hyperspectral imaging using anomaly, polarization and spectral identification approaches for the standoff detection (13 meters) of nitroaromatic explosives on realistic painted surfaces based upon the colorimetric differences between tetryl and TNT which are enhanced by solar irradiation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

[CuCln](2-n) Ion-Pair Species in 1-Ethyl-3-Methylimidazolium Chloride Ionic Liquid-Water Mixtures: Ultraviolet-Visible, X-ray Absorbtion Fine Structure, and Density Functional Theory Characterization

We report details of the coordination environment about Cu(II) in a pure ionic liquid, 1- ethyl-3-methylimidazolium chloride ([EMIM]Cl) and in mixtures containing varying amounts of water from 0-100% of the [EMIM]Cl. There are many stages in the ion pairing of the divalent cation, Cu(II) including the contact ion pairing of Cu2+ with multiple Cl- to form various CuCln (2-n) polyanions. Thereis also the subsequent solvation and ion pairing of the polychlorometallate anion with the EMIM+ cation. Using a combination of x-ray absorption fine structure (XAFS), UV-Vis spectroscopy and electronic structure calculations (TDDFT) we are able to follow the detailed structural changes about Cu(II). Ion pair formation is strongly promoted in [EMIM]Cl by the low dielectric constant and by the extensive breakdown of the water hydrogen bond network in [EMIM]Cl/water mixtures. In the [EMIM]Cl solvent the CuCl4 2- species dominates and it’s geometry is quite similar to gas-phase structure. These results are important in understanding catalysis and separation processes involving transition metals in ionic liquid systems.

08 HYDROGEN↗

Measurement of HONO, HNCO, and Other Inorganic Acids by Negative-ion Proton-Transfer Chemical-Ionization Mass Spectrometry (NI-PT-CIMS):Application to Biomass Burning Emissions.

A negative-ion proton transfer chemical ionization mass spectrometric technique (NI-PT-CIMS), using acetate as the reagent ion, was applied to the measurement of volatile inorganic acids of atmospheric interest: hydrochloric (HCl), nitrous (HONO) nitric (HNO3), and isocyanic (HNCO) acids. Gas phase calibrations through the sampling inlet showed the method to be intrinsically sensitive (6-16 cts/pptv), but prone to inlet effects for HNO3 and HCl. The ion chemistry was found to be insensitive to water vapor concentrations, in agreement with previous studies of carboxylic acids. The inlet equilibration times for HNCO and HONO were 2 to 4 seconds, allowing for measurement in biomass burning studies. Several potential interferences in HONO measurements were examined: decomposition of HNO3•NO3- clusters within the CIMS, and NO2-water production on inlet surfaces, and were quite minor (>_1%, 3.3%, respectively). The detection limits of the method were limited by the instrument backgrounds in the ion source and flow tube, and were estimated to range between 16 and 50 pptv (parts per trillion by volume). The comparison of HONO measured by CIMS and by in situ FTIR showed good correlation and agreement to within 17%. The method provided rapid and accurate measurements of HNCO and HONO in controlled biomass burning studies, and suggest both as products of biomass burning.

09 BIOMASS FUELS↗

The hydration number n of calcium dipicolinate trihydrate, CaDP center dot nH(2)O, and its effect on the IR spectra of sporulated Bacillus bacteria

Previous results have shown a unique "quartet" of peaks in the infrared spectra of the sporulated phase of Bacillus bacteria, the four peaks being observed reproducibly for many different species of Bacillus endospores. We consistently observe peaks at 766, 725, 701, and 659 cm-1 and with the same relative amplitudes, as well as other spore peaks at 1441, 1277, 1015 cm-1. We have previously suggested that the peaks arise from calcium dipicolinate, not the conjugate acid. In this paper we conduct a theoretical and experimental study to show that the IR peaks not only arise from the calcium dipicolinate, a known spore component, but specifically the trihydrate salt, CaDP•3H2O. This is shown by calculating the absolute IR intensities of the lone dipicolinate dianion, the calcium salt, as well as the mono-, di- and tri-hydrate salts of calcium dipicolinate. The quartet peaks arise from the crystalline trihydrate salt as we verify both experimentally as well as using quantum chemistry methods. Using a method whereby the calculated intensities are not normalized, only the trihydrate spectrum shows low frequency modes (below 1000 cm-1, including the quartet) having intensities comparable to those of the pyridine ring. The vibrational modes in this part of the spectrum are associated with many internal coordinate motions including contributions from the Ca2+ counterion and the three waters including Ca-O-H bends, H2O-Ca-O torsions and O-C-O bends. Index Headings: Infrared, calcium dipicolinate, Bacillus, Bacteria, Endospores

59 BASIC BIOLOGICAL SCIENCES↗