Engineering Papers⌕ Search

Engineering topics

Johnson, Timothy C.

Publications and source records attributed to Johnson, Timothy C..

Electrical Resistivity Tomography based monitoring of stress perturbations to optimize placement of high-precision strain meters

The Center for Understanding Subsurface Signals and Permeability is a new U.S. Department of Energy Earthshot Center focused on understanding and predicting the long-term evolution of permeability in enhanced geothermal systems. The center will use a highly instrumented testbed within the Sanford Underground Research Facility to conduct field scale experiments that elucidate and test capabilities to simulate geochemical-geomechanical interactions and permeability evolution. Here we demonstrate initial developments using previously collected electrical resistivity tomography (ERT) monitoring data with high-performance multi-physics modelling advancements to inform the optimal location of two new monitoring boreholes. Specifically, ERT monitoring data collected during shear stimulation testing shows marked responses to changes in stress during borehole pressurization. We demonstrate how the same response is being simulated, ultimately to train a machine-learning algorithm to estimate rock properties and enable enhanced prediction of stress and strain responses anticipated during future testing campaigns.

Stress, EGS, CUSSP, 3D Electrical Imaging↗

Structure and Dynamics of Aqueous Electrolytes at Quartz (001) and (101) Surfaces

Here, understanding and describing reactivity at mineral-water interfaces such as ion adsorption, the kinetics of dissolution, or surface charge development depends on our ability to improve the accuracy of electrical double layer (EDL) models. While molecular dynamics (MD) simulations are routinely used to investigate the structure and energetics of adsorbed ions comprising the EDL, less attention is paid to their self-diffusion dynamics, which can uniquely inform on coupling to interfacial reactions. Here we use MD to investigate both the organization and diffusion dynamics of water and electrolyte ions (NaCl, KCl, CaCl 2 ) at hydroxylated quartz (001) and (101) surfaces, a comparison which allowed us to assess surface structural effects of corrugation and silanol density. We found that inner- versus outer-sphere complex formation depends on cation size and charge but not necessarily hydration energies. Participation of surface silanols in the hydration spheres of Na + and K + generally indicated their preference for inner-sphere complexation, but this depends strongly on the orientation of the surface considered through its influence over the organization and dynamics of adsorbed water layers. In particular, surface orientation substantially affects the diffusive behavior of the near-surface water. Na + was found to decrease the mobility of water in the first layer, consistent with an increasing frequency of hydrolysis implied by faster quartz dissolution rates observed in experiments via the well known salt effect. Our results are also in good agreement with the observed dissolution rate of quartz vs. surface adsorption strength measure by Dove and Nix. This study sets the stage for a forthcoming paper examining how the dynamics at quartz/electrolyte interfaces are influenced by externally applied electric fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrical Resistivity Tomography Monitoring of In Situ Soil Flushing at the Hanford 100-K East Area: 100KE Soil Flushing Monitoring

Former operations in the 100-KE Area at the Hanford Site resulted in vadose zone hexavalent chromium that provides a source of groundwater contamination. Previous efforts to remediate vadose zone chromium involved excavation and offsite treatment of contaminated soils. Although much of the chromium was removed, contamination still exists in native soil between the water table and the bottom of the pit, which has since been backfilled. In-situ soil flushing was tested at the 100-KE Area to accelerate the removal of the remaining hexavalent chromium in the vadose zone. Soil flushing works by applying clean flush water at the surface, which mobilizes and transports chromium as it migrates downward to the water table. Once the chromium reaches the water table, it is hydraulically contained, extracted, and treated through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. Therefore, performance monitoring requires and understanding of flush water migration through the vadose zone. It is challenging to comprehensively assess soil flushing performance via borehole access due to the limited volume of investigation afforded by a given wellbore. As an alternative, 3D time-lapse electrical resistivity tomography (ERT) was tested as a method of monitoring the distribution of flush water over time within the vadose zone. ERT is a method of imaging the bulk electrical conductivity of the subsurface, which is highly dependent on water saturation levels in unconsolidated and unsaturated sediments. Thus, the timing and location of changes in bulk conductivity caused by soil flushing can be used to infer flush water migration pathways. In this report we present results of 3D time-lapse ERT imaging during two separate soil flushing campaigns conducted during the spring and summer months of 2022 and 2023. Results show generally that: 1) Pit backfill materials appear to nominally have larger permeability than native soils. Consequently, the boundary between pit backfill and native soil had a significant impact on flush water migration, causing some flush water to migrate along the pit boundary to the bottom of the pit. 2) Non-uniform flows, likely caused by variations in hydrogeologic properties, developed in the pit backfill materials, resulting in uneven flush water distribution on the southern margin of the soil flushing zone. 3) Redistribution of water at the interface between backfill materials and Hanford formation materials likely facilitated elevated and uniform distribution of flush water within native soils beneath the deeper parts of the pit boundary beneath the center of the flush zone, which presumably overlie soils with elevated chromium contamination. These areas appear to have been infiltrated by higher volumes of flush water than the northern and southern margins of the flush zone. 4) In comparison to 2022, high flush water application rates significantly improved flush water distribution throughout the target flushing zone. 5) Imaging resolution was limited to a depth of approximate 20 meters below the land surface, due primarily to limitations on the lateral extent of the surface ERT array. The ~10 m region of the vadose zone between approximately 130 meters elevation and the water table at approximately 120 meters elevation was unresolved.

100 Area↗

Detecting fractures and monitoring hydraulic fracturing processes at the first EGS Collab testbed using borehole DAS ambient noise

Enhanced geothermal systems (EGS) require cost-effective monitoring of fracture networks. We validate the capability of using borehole distributed acoustic sensing (DAS) ambient noise for fracture monitoring using core photos and core logs. The EGS Collab project has conducted 10 m scale field experiments of hydraulic fracture stimulation using 50–60 m deep experimental wells at the Sanford Underground Research Facility (SURF) in Lead, South Dakota. The first EGS Collab testbed is located at 1616.67 m (4850 ft) depth at SURF and consists of one injection well, one production well, and six monitoring wells. All wells are drilled subhorizontally from an access tunnel called a drift. The project uses a single continuous fiber-optic cable installed sequentially in the six monitoring wells to record DAS data for monitoring hydraulic fracturing during stimulation. We analyze 60 s time records of the borehole DAS ambient noise data and compute the noise root-mean-square (rms) amplitude on each channel (points along the fiber cable) to obtain DAS ambient noise rms amplitude depth profiles along the monitoring wellbore. Our noise rms amplitude profiles indicate amplitude peaks at distinct depths. We compare the DAS noise rms amplitude profiles with borehole core photos and core logs and find that the DAS noise rms amplitude peaks correspond to the locations of fractures or lithologic changes indicated in the core photos or core logs. We then compute the hourly DAS noise rms amplitude profiles in two monitoring wells during three stimulation cycles in 72 h and find that the DAS noise rms amplitude profiles vary with time, indicating the fracture opening/growth or closing during the hydraulic stimulation. Our results demonstrate that borehole DAS passive ambient noise can be used to detect fractures and monitor fracturing processes in EGS reservoirs.

58 GEOSCIENCES↗

Systems and methods for determining ground water-surface water interactions

Systems for determining GW/SW interaction are provided. The systems can include: a sensing assembly comprising sensors for pressure, fluid conductivity, temperature, and transfer resistance; processing circuitry operatively coupled to the sensing assembly and configured to receive data from the sensing assembly and process the data to provide a GW/SW interaction, wherein the data includes pressure, fluid conductivity, temperature, transfer resistance data. Methods for determining GW/SW interaction are provided. The methods can include: receiving real time data including pressure, fluid conductivity, temperature, and transfer resistance; from at least some of the data received simulating the SW/GW interaction; and fitting the real time data with the simulated data to provide actual SW/GW interaction.

Johnson, Timothy C.↗

Joint Inversion of Surface Electrical Resistivity Tomography and Seismic Refraction Data between the 200 Areas

Geologic stratigraphy on the Hanford Site influences groundwater and contaminant migration through the aquifer system and the vadose zone. The current geologic framework model (GFM) relies heavily on a sparse distribution of borehole data in some locations to map geologic contacts and hydrologic properties in the subsurface. Non-invasive geophysical methods such as electrical resistivity tomography (ERT), transient electromagnetic surveying, and seismic imaging are being used at Hanford to map subsurface structure in areas with limited well observations. This is to develop and mature the capability of geophysical methods to aid in GFM refinement, to identify regions of subsurface complexity, and for optimal well siting. A joint inversion of co-located seismic refraction and ERT data was carried out for data collected on a ~2.3-km profile between the 200 Areas on the Hanford Site. While ERT and seismic refraction images have sensitivity to overlapping physical properties (porosity, moisture content, lithology), the resolution and physics used to acquire each of these datasets are different and therefore information can be different or mutually complementary. Performing a joint inversion provides a reasonable option for a coherent, coupled interpretation for mutually complementary datasets. Between the 200 Areas, there are few boreholes to interpret the geologic framework model, and these data sets were obtained to provide a first line of evidence toward identifying stratigraphic structure. The seismic refraction and ERT data were independently inverted during fiscal year 2022 and broadly showed a two-layer structure with a trough-like feature that is ~1 km wide and upwards of 150 m deep. The depth of the trough feature was greater in the ERT image compared to the seismic image, which indicated a maximum depth of approximately 110 m. The objective of the joint inversion described in this report was to invert the seismic refraction and ERT data together while constraining the ERT image to be structurally similar to the seismic refraction image. The approach was applied using the geophysical inverse modeling program E4D, which has the capability to invert first-arrival times from seismic refraction data and ERT resistances using a “cross-gradient” constraint. The application of cross-gradient constraints with different weights produces ERT models that show a high degree of similarity within the upper 100 m (above ~120 m elevation). None of the ERT models show an improved structural similarity to the seismic result; therefore, it is recommended that further attempts to jointly interpret these models focus on petrophysics and image resolution. Petrophysical measurements of core samples would improve knowledge of what drives the ERT response in this region and, along with downhole geophysical measurements, could be used to “ground truth” the surface-based geophysical results. Image resolution studies would provide insight into which regions of the inverted images are reliable and which regions are poorly constrained.

58 GEOSCIENCES↗

Deep Vadose Zone Monitoring Test Bed (FY23 Status Report)

A subsurface air injection at the Hanford Site’s Deep Vadose Zone Monitoring Test Bed was completed to realize a change in subsurface hydrologic conditions in accordance with a soil desiccation remedy. The injection mimicked a previous injection at the site that was performed in accordance with a vadose zone treatability study. Unlike the previous test which relied on electrical methods only, the change in hydrologic conditions during the recent test was also monitored using cross-hole seismic sensing methods to assess the ability of the seismic methods to evaluate changes in moisture conditions of desiccated sediment at the field scale. Data from in situ neutron probes indicates a reduction of soil moisture in the vicinity of the injection well due to the air injection. Similar changes were observed in the time-lapse electrical resistivity and seismic data, which indicates a loss of soil moisture over time. Tomographic inversions of the time-lapse geophysical data illustrate the 2D and 3D features of the soil moisture distribution over time. Time-lapse electrical resistivity tomography (ERT) results show a reduction in the electrical conductivity of the subsurface in the vicinity of the injection well, with most changes occurring within the screened interval. Similar patterns are observed in the seismic tomography results, with both methods illustrating two lobe-shaped features of reduced soil moisture. Use of seismic and ERT technologies in tandem takes advantage of two complementary geophysical monitoring technologies, providing increased sensitivity to specific hydrologic conditions. The multiphysics approach, therefore, has the potential to improve the ability to estimate subsurface moisture conditions from sensor-based and remotely sensed geophysical data that will ultimately improve the ability of remediation contractors to evaluate remedy performance.

58 GEOSCIENCES↗