Engineering Papers⌕ Search

Engineering topics

Johnson, T

Publications and source records attributed to Johnson, T.

Effective field theory interactions for liquid argon target in DarkSide-50 experiment

We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 ± 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper limits between 2.4×10-45 cm2 and 2.3×10-42 cm2 (8.9 ×10-45 cm2 and 6.0 ×10-42 cm2) for WIMPs of mass of 100 GeV/c2 (1000 GeV/c2) at 90% confidence level.

Agnes, P↗

Low-mass Dark Matter Search with the DarkSide-50 Experiment

We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and is almost entirely accounted for by known background sources. We obtain a 90% C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section of dark matter WIMPs on nucleons, extending the exclusion region for dark matter below previous limits in the range 1.8-6 GeV/c^2.

Agnes, P↗

Fracture and Flow Designs for the Collab/SIGMA-V Project

The first experiment of the Enhanced Geothermal Systems (EGS) Collab (a.k.a Stimulation Investigations for Geothermal Modeling Analysis and Validation (SIGMA-V)) project is designed to comprehensively monitor a series of hydraulic fracture stimulations and subsequent flow tests. This experiment is planned for the 4850 Level in the Sanford Underground Research Facility (SURF), located at the former Homestake Gold Mine, in Lead, South Dakota. The target host rock for these stimulations and flow tests is a phyllite schist known as the Poorman formation. This paper discusses at a high level the engineering design for the stimulation and fracture monitoring system, the considerations for the test bed construction, and the preliminary stimulation modeling. Furthermore, this paper will highlight the intricate ways that predictive modeling can be used for testbed and stimulation design. This project is funded by the United States Department of Energy, Geothermal Technologies Office (GTO).

Knox, Hunter↗

MO-FG-CAMPUS-JeP1-04: Evaluating DECT Vs SECT Range Differences in Proton Therapy Using Clinical Data

Purpose: Range uncertainty from X-ray CT number conversion to stopping power ratio (SPR) is one of the key factors limiting the potential of proton therapy. The large margins required for deep seated tumors degrade the organ sparing achievable with the technology. Of interest is the application of dual energy CT (DECT) to SPR estimation. In this planning study proton range differences between SECT and DECT have been quantified for brain cases. Methods: A last generation dual source DECT scanner was used to acquire SECT (150 kVp with Sn filtration) and DECT (additionally 90 kVp) scans of phantoms and 5 head trauma patients, acting as surrogate cancer patients. Phantom materials were characterized in terms of SPR in a particle beam to obtain reference values. IMPT treatment plans were generated on the basis of SECT and DECT SPR images for hypothetical brain tumors using a short and a long beam path. Range differences between SECT and DECT from plan recalculations were evaluated in beam-eye-view (BEV) by comparing the 80% isodose. Results: For the 18 phantom materials the SECT RMS SPR errors were 2.6% compared to 1.1% for DECT. Group median relative range differences between SECT and DECT plans were −1.0% for the short beam path over the 5 patients investigated in this study. For the long beam path the median difference was −1.4%. These relative range differences corresponded to −0.5 mm and −1.4 mm shifts respectively. Conclusion: This is the first study performing proton therapy treatment planning on DECT patient images. Important range differences of more than 1 mm were observed between SECT and DECT treatment plans, and DECT SPR accuracy was found superior on the basis of phantom measurements. While the patients investigated in this study did not have brain tumors, the findings we observed should apply to cancer patients. Deutsche Forschungsgemeinschaft (MAP); Bundesministerium fur Bildung und Forschung (01IB13001)

60 APPLIED LIFE SCIENCES↗

SU-C-207-07: Quantification of Coronary Artery Cross-Sectional Area in CT Angiography Using Integrated Density: A Phantom Study

Purpose: To investigate the feasibility of quantifying the cross-sectional area (CSA) of coronary arteries using integrated density in a physics-based model with a phantom study. Methods: In this technique the total integrated density of the object as compared with its local background is measured so it is possible to account for the partial volume effect. The proposed method was compared to manual segmentation using CT scans of a 10 cm diameter Lucite cylinder placed inside a chest phantom. Holes with cross-sectional areas from 1.4 to 12.3 mm{sup 2} were drilled into the Lucite and filled with iodine solution, producing a contrast-to-noise ratio of approximately 26. Lucite rods 1.6 mm in diameter were used to simulate plaques. The phantom was imaged with and without the Lucite rods placed in the holes to simulate diseased and normal arteries, respectively. Linear regression analysis was used, and the root-mean-square deviations (RMSD) and errors (RMSE) were computed to assess the precision and accuracy of the measurements. In the case of manual segmentation, two readers independently delineated the lumen in order to quantify the inter-reader variability. Results: The precision and accuracy for the normal vessels using the integrated density technique were 0.32 mm{sup 2} and 0.32 mm{sup 2}, respectively. The corresponding results for the manual segmentation were 0.51 mm{sup 2} and 0.56 mm{sup 2}. In the case of diseased vessels, the precision and accuracy of the integrated density technique were 0.46 mm{sup 2} and 0.55 mm{sup 2}, respectively. The corresponding results for the manual segmentation were 0.75 mm{sup 2} and 0.98 mm{sup 2}. The mean percent difference for the two readers was found to be 8.4%. Conclusion: The CSA based on integrated density had improved precision and accuracy as compared with manual segmentation in a Lucite phantom. The results indicate the potential for using integrated density to improve CSA measurements in CT angiography.

60 APPLIED LIFE SCIENCES↗

SU-E-I-25: Quantification of Coronary Artery Cross-Sectional Area in CT Angiography Using Integrated Density: A Simulation Study

Purpose: To develop a physics-based model for accurate quantification of the cross-sectional area (CSA) of coronary arteries in CT angiography by measuring the integrated density to account for the partial volume effect. Methods: In this technique the integrated density of the object as compared with its local background is measured to account for the partial volume effect. Normal vessels were simulated as circles with diameters in the range of 0.1–3mm. Diseased vessels were simulated as 2, 3, and 4mm diameter vessels with 10–90% area stenosis, created by inserting circular plaques. A simplified two material model was used with the lumen as 8mg/ml Iodine and background as lipid. The contrast-to-noise ratio between lumen and background was approximately 26. Linear fits to the known CSA were calculated. The precision and accuracy of the measurement were quantified using the root-mean-square fit deviations (RMSD) and errors to the known CSA (RMSE). Results compared to manual segmentation of the vessel lumen. To assess the impact of random variations, coefficients of variation (CV) from 10 simulations for each vessel were computed to determine reliability. Measurements with CVs less than 10% were considered reliable. Results: For normal vessels, the precision and accuracy of the integrated density technique were 0.12mm{sup 2} and 0.28mm{sup 2}, respectively. The corresponding results for manual segmentation were 0.27mm{sup 2} and 0.43mm{sup 2}. For diseased vessels, the precision and accuracy of the integrated density technique were 0.14mm{sup 2} and 0.19mm{sup 2}. Corresponding results for manual segmentation were 0.42mm{sup 2} and 0.71mm{sup 2}. Reliable CSAs were obtained for normal vessels with diameters larger than 1 mm and for diseased vessels with area as low as 1.26mm2. Conclusion: The CSA based on integrated density showed improved precision and accuracy as compared with manual segmentation in simulation. These results indicate the potential of using integrated density to quantify CSA of coronary arteries in CT angiography.

60 APPLIED LIFE SCIENCES↗