Engineering PapersSearch

Engineering topics

Johnson, Dean L.

Publications and source records attributed to Johnson, Dean L..

Ambient Performance Testing of the CubeSat Infrared Atmospheric Sounder (CIRAS)

Hyperspectral infrared measurements of Earth’s atmosphere from space have proven their value for weather forecasting, climate science and atmospheric composition. The CubeSat Infrared Atmospheric Sounder (CIRAS) instrument will demonstrate a fully functional infrared temperature, water vapor and carbon monoxide sounder in a CubeSat sized volume for at least an order of magnitude lower cost than legacy systems. Design for a CubeSat significantly reduces cost of access to space and enables flight in a constellation to reduce revisit time and enable new measurements including 3D winds. A technology demonstration of CIRAS is currently under development at JPL. The effort has completed integration and ambient testing of a high fidelity brassboard, complete with the flight configured optics assembly developed by Ball Aerospace with a JPL Immersion Grating and Black Silicon Entrance Slit. The brassboard includes a flight-configured High Operating Temperature Barrier Infrared Detector (HOT-BIRD) mounted in an Integrated Dewar Cryocooler Assembly (IDCA), enabling testing in the ambient environment. Ambient testing included radiometric testing of the system to characterize the instrument operability and NEdT. Spatial testing was performed to characterize the system line spread function (LSF) in two axes and report FWHM of the LSF. Spectral testing involved an air path test to characterize the spectral/spatial transformation matrix, and an etalon was used to measure the Spectral Response Functions (SRFs). Results of the testing show the CIRAS performs exceptionally well and meets the key performance required of the system. The end result of testing is the CIRAS instrument now meets TRL 4 with confidence in a brassboard configuration ready for thermal vacuum (TVac) testing necessary to achieve TRL 5 for the system.

Wilson, Robert C.

Characterization Testing of Lockheed Martin High-Power Micro Pulse Tube Cryocooler

This paper describes the thermal vacuum, microphonics, magnetics, and radiation testing and results of a Lockheed Martin high-power micro pulse tube cryocooler. The thermal performance of the microcooler was measured in vacuum for heat reject temperatures between 185 and 300 K. The cooler was driven with a Chroma 61602 AC power source for input powers ranging from 10 to 60 W and drive frequency between 115 and 140 Hz during thermal performance testing. The optimal drive frequency was dependent on both input power and heat reject temperature. In addition, the microphonics of the cooler were measured with the cooler driven by Iris Technologies LCCE-2 and HP-LCCE drive electronics for input powers ranging from 10 to 60 W and drive frequency between 135 and 145 Hz. The exported forces were strongly dependent on input power while only weakly dependent on the drive frequency. Moreover, the exported force in the compressor axis was minimized by closed loop control with the HP-LCCE. The cooler also survived a 500 krad radiation dose while being continuously operated with 30 W of input power at 220 K heat rejection temperature in vacuum. Finally, the DC and AC magnetic fields around the cooler were measured at various locations.

Rodriguez, Jose I.

Thermal Strap Increases Cryocooling Efficiency

Report discusses concept for decreasing compressor power consumed by spacecraft mechanical cryocooler providing 0.5 W of refrigeration at temperature of 61 K at tip of cold finger. Involves connecting thermal strap between radiator or other heat sink at intermediate temperature and stiffening ring located on cold finger about one-third way from base to tip and attains temperature of about 250 K during normal operation. Depending upon specific design, electrical power consumed by mechanical cryocooler reduced by half.

Ross, Ronald G., Jr.

Demonstration of active vibration control on a stirling-cycle cryocooler testbed

SatCon Technology Corporation has demonstrated excellent vibration reduction performance using active control on the JPL Stirling-cycle cryocooler testbed. The authors address the use of classical narrowband feedback control to meet the cryocooler vibration specifications using one cryocooler in a self-cancellation configuration. Similar vibration reduction performance was obtained using a cryocooler back-to-back configuration by actively controlling a reaction mass actuator that was used to mimic the second cooler.

Johnson, Bruce G.

Electromagnetic compatibility characterization of a BAe Stirling-cycle cryocooler for space application

This paper describes the electromagnetic compatibility (EMC) measurements of an 80-K Stirling-cycle cooler. The measurements, performed in the JPL EMC test facility, include dc magnetic field characterization, radiated magnetic and electric field emissions, and conducted emissions on the internal lines between the cooler electronics and the cooler. The measurements conform to both the MILSTD-461C specifications as well as to the specifications for the NASA Earth Observing System.

Johnson, Dean L.