Uncertainty Budget for Detector-Based Absolute Radiometric Calibration With GLAMR

The accuracy of the absolute radiometric calibration (RadCal) for remote sensing instruments is essential to their wide range of applications. The uncertainty associated to the traditional source-based RadCal method is assessed at a 2% (k=1) or higher level for radiance measurement. To further improve the accuracy to meet the demands of climate studies, a detector-based approach using tunable lasers as a light source has been devised. The Goddard Laser for Absolute Measurement of Radiance, known as the GLAMR system, is a notable example of the incorporation of such technology. Using transfer radiometers calibrated at NIST as calibration standards, the absolute spectral response (ASR) function of a remote sensing instrument is measured with its uncertainty traceable to the International System of Units. This paper presents a comprehensive uncertainty analysis of the detector-based absolute RadCal using the GLAMR system. It identifies and examines uncertainty sources during the GLAMR RadCal test, including those from the GLAMR system, the testing configuration, and data processing methodologies. Analysis is carried out to quantify the contribution of each source and emphasize the most influential factors. It is shown that the calibration uncertainty of GLAMR RadCal can be better than 0.3% (k=1) in the wavelength range of 350-950 nm and 0.6% (k=1) between 950-2300 nm, with the exception of regions with strong water absorption. In addition, recommendations are made to refine the calibration process to further reduce the uncertainty.

Zhipeng Wang

Prelaunch Spectral Characterization of the Operational Land Imager-2

The Landsat-9 satellite, launched in September 2021, carries the Operational Land Imager-2 (OLI-2) as one of its payloads. This instrument is a clone of the Landsat-8 OLI and its mission is to continue the operational land imaging of the Landsat program. The OLI-2 instrument is not significantly different from OLI though the instrument-level pre-launch spectral characterization process was much improved. The focal plane modules used on OLI-2 were manufactured as spares for OLI and much of the spectral characterization of the components was performed for OLI. However, while the spectral response of the fully assembled OLI was characterized by a double monochromator system, the OLI-2 spectral characterization made use of the Goddard Laser for Absolute Measurement of Radiance (GLAMR). GLAMR is a system of tunable lasers that cover 350–2500 nm which are fiber-coupled to a 30 in integrating sphere permanently monitored by NIST-traceable radiometers. GLAMR allowed the spectral characterization of every detector of the OLI-2 focal plane in nominal imaging conditions. The spectral performance of the OLI-2 was, in general, much better than requirements. The final relative spectral responses (RSRs) represent the best characterization any Landsat instrument spectral response. This paper will cover the results of the spectral characterization from the component-level to the instrument-level of the Landsat-9 OLI-2.

Landsat-9

New Mie Scattering Diffuse Targets Development and Characterization

Earth science remote sensing observations require the detection and measurement of light originating from bright targets, such as clouds, and darker targets, such as an open ocean. This requirement drives the need to design, develop, and characterize improved calibration targets in support of current and future NASA instruments. New diffuse targets to be used as spectral albedo calibration standards were developed and characterized. The new targets based on fused silica or/and pressed and sintered Polytetrafluoroethylene (PTFE) were developed to be Earth scene specific. The various reflectance levels are achieved by modifying the material parameters, thickness, and surface finish. The new targets were characterized in laboratory and simulated space environments. We acquired high accuracy reflectance and transmittance data using a precision optical scatterometer and spectrophotometer located in the NASA Goddard Space Flight Center (GSFC) Diffuser Calibration Lab. The Total hemispherical reflectance (THR) and Bidirectional Reflectance Distribution Function (BRDF) were measured over the range of solar incident and scattered elevation and azimuthal angles typically realized on orbit by remote sensing instruments. We intend to space certify the new calibration targets after concluding on-orbit testing on the International Space Stations (ISS) scheduled for the second half of 2023.

Georgi Georgiev

U.S. Plans for Geostationary Hyperspectral Infrared Sounders

NOAA’s Geostationary Extended Observations (GeoXO) satellite system will provide advanced hyperspectral resolution infrared observations. The first GeoXO Sounder (GXS) will fly in the mid-2030s and provide an unprecedented level of information. The plans are for the GXS to be located at a longitude over the center of the U.S. The GXS will be as much of an improvement over the legacy Geostationary Operational Environmental Satellite (GOES)broad-spectral resolution sounder as the Advanced Baseline Imager (ABI) was to the legacy imager. The GXS will be the U.S. contribution to the global ring of geostationary advanced infrared sounders. The GXS sensor will provide unique information about the vertical structure of moisture, winds, and temperature to support both Numerical Weather Prediction (NWP)and nowcasting applications.

Timothy J Schmit

Polarization performance simulation for the GeoXO atmospheric composition instrument: NO2 retrieval impacts

NOAA’s Geostationary Extended Observations (GeoXO) constellation will continue and expand on the capabilities of the current generation of geostationary satellite systems to support US weather, ocean, atmosphere, and climate operations. It is planned to consist of a dedicated atmospheric composition instrument (ACX) to support air quality forecasting and monitoring by providing similar capabilities to missions such as TEMPO (Tropospheric Emission: Monitoring Pollution), currently planned to launch in 2023, and Ozone Monitoring Instrument (OMI), TROPOMI (TROPOspheric Monitoring Instrument), and GEMS (Geostationary Environment Monitoring Spectrometer) currently in operation. As the early phases of ACX development are progressing, design trade-offs are being considered to understand the relationship between instrument design choices and trace gas retrieval impacts. Some of these choices will affect the instrument polarization sensitivity (PS), which can have radiometric impacts on environmental satellite observations. We conducted a study to investigate how such radiometric impacts can affect NO2 retrievals by exploring their sensitivities to time of day, location, and scene type with an ACX instrument model that incorporates PS. The study addresses the basic steps of operational NO2 retrievals: the spectral fitting step and the conversion of slant column to vertical column via the air mass factor (AMF). The spectral fitting step was performed by generating at-sensor radiance from a clear sky scene with a known NO2 amount, the application of an instrument model including both instrument PS and noise, and a physical retrieval. The spectral fitting step was found to mitigate the impacts of instrument PS. The AMF-related step was considered for clear sky and partially cloudy scenes, where instrument PS can lead to errors in interpreting the cloud content, propagating to AMF errors and finally to NO2 retrieval errors. For this step, the NO2 retrieval impacts were small but non-negligible for high NO2 amounts; we estimated that a typical high NO2 amount can cause maximum of 0.25 x 10^15 molecules/cm^2 for a PS of 5%. These simulation capabilities were designed to aid in the development of a GeoXO atmospheric composition instrument that will improve our ability to monitor and understand the Earth’s atmosphere.

trace gases

Polarization Performance Simulation for the GeoXO Atmospheric Composition Instrument: NO2 Retrieval Impacts

NOAA's Geostationary Extended Observations (GeoXO) constellation will continue and expand on the capabilities of the current generation of geostationary satellite systems to support US weather, ocean, atmosphere, and climate operations. It is planned to consist of a dedicated atmospheric composition instrument (ACX) to support air quality forecasting and monitoring by providing capabilities similar to missions such as TEMPO (Tropospheric Emission: Monitoring Pollution), currently planned to launch in 2023, as well as OMI (Ozone Monitoring Instrument), TROPOMI (TROPOspheric Monitoring Instrument), and GEMS (Geostationary Environment Monitoring Spectrometer) currently in operation. As the early phases of ACX development are progressing, design trade-offs are being considered to understand the relationship between instrument design choices and trace gas retrieval impacts. Some of these choices will affect the instrument polarization sensitivity (PS), which can have radiometric impacts on environmental satellite observations. We conducted a study to investigate how such radiometric impacts can affect NO2 retrievals by exploring their sensitivities to time of day, location, and scene type with an ACX instrument model that incorporates PS. The study addresses the basic steps of operational NO2 retrievals: the spectral fitting step and the conversion of slant column to vertical column via the air mass factor (AMF). The spectral fitting step was performed by generating at-sensor radiance from a clear-sky scene with a known NO2 amount, the application of an instrument model including both instrument PS and noise, and a physical retrieval. The spectral fitting step was found to mitigate the impacts of instrument PS. The AMF-related step was considered for clear-sky and partially cloudy scenes, for which instrument PS can lead to errors in interpreting the cloud content, propagating to AMF errors and finally to NO2 retrieval errors. For this step, the NO2 retrieval impacts were small but non-negligible for high NO2 amounts; we estimated that a typical high NO2 amount can cause a maximum retrieval error of 0.25×1015 molec. cm−2 for a PS of 5 %. These simulation capabilities were designed to aid in the development of a GeoXO atmospheric composition instrument that will improve our ability to monitor and understand the Earth's atmosphere.

Aaron Pearlman

Landsat 9 Mission Update and Status

Landsat 9 is currently undergoing testing at the integrated observatory level in preparation for launch from Vandenberg Air Force Base in 2021. Landsat 9 will replace Landsat 7 in orbit, 8 days out of phase with Landsat 8. Landsat 9 is largely a copy of Landsat 8 in terms of instrumentation, with an Operational Land Imager (OLI), model #2 and a Thermal Infrared Sensor (TIRS), model #2. The TIRS-2 is more significantly changed from TIRS with increased redundancy, as well as changes to the telescope baffling to improve stray light control and a revised scene select mirror encoder mechanism. Data quality of the Landsat 9 instruments is comparable to, or better than the Landsat 8 ones, with an increase to 14 bits of data transmitted and more detailed pre-launch characterization for OLI-2, and with more detailed characterization of the TIRS-2 pre-launch, in addition to the improved stray light control. The performance of the two instruments is summarized and compared to that of the Landsat 8 instruments.

Brian Markham

Prelaunch Radiometric Calibration and Uncertainty Analysis of Landsat Thermal Infrared Sensor 2

The Thermal Infrared Sensor-2 (TIRS-2) that will be onboard Landsat 9 has undergone a prelaunch testing campaign to characterize its radiometric, spectral, and spatial performances and demonstrate compliance to its requirements. This work reviews the key elements of the instrument-level radiometric testing using an SI-traceable source to derive its uncertainties. Those arising from on-orbit calibration using the TIRS-2 onboard blackbody are also discussed. We use a Monte Carlo approach to propagate the uncertainties through a nonlinear calibration equation and address both random and systematic uncertainty terms. Achieving the required performance demonstrates the instrument's potential for enhancing our understanding of the Earth's environment.

Aaron Pearlman

GOES-16 ABI Solar Reflective Channel Validation for Earth Science Application

This paper presents the validation results of GOES-16 Satellite's Advanced Baseline Imager (ABI) obtained from a reflectance-based field campaign undertaken at the Salar de Uyuni in Bolivia in June 2017. In situ ground measurements are used to characterize the surface reflectance and the atmosphere in order to constrain the radiative transfer code and predict at-sensor reflectance (also referred to as top-of-atmosphere (TOA) reflectance) to compare with concurrent GOES-16 ABI measurements. The five-day field campaign provided repeated TOA reflectance estimates, allowing assessment not only of the calibration accuracy of the ABI reflective channels 1, 2, 3, 5 and 6, but also of its stability over the duration of the campaign. The results show that the accuracy of the ABI reflective channels calibration is within specification for channels 1, 3, 5, and 6 - average biases within 2%; for channel 2 the bias is 5%. The estimated uncertainty on the derived biases is 2–2.4%. Some calibration stability issues were present in the ABI calibration at the time of the campaign: (i) a jump on the order of 2% in channels 1 and 6, coincident with an ABI solar calibration event, reflects an instability of the ABI gains in these channels, and (ii) short-term variability in channels 1 and 2 is due to striping (ABI detector-todetector calibration differences). Continued validation and subsequent reprocessing of ABI reflectance imagery would allow Earth scientists to fully benefit from the high spatial and spectral fidelity of the GOES-16 ABI diurnal measurements at the continental scale.

Joel McCorkel

LANDSAT 9: Mission Status and Prelaunch Instrument Performance Characterization and Calibration

Landsat 9 is currently under development as a joint effort between NASA and the United States Geological Survey (USGS). Landsat 9 is largely a rebuild of Landsat 8 and has the same two sensors, an Operational Land Imager (OLI) and a Thermal InfraRed Sensor(TIRS). The OLI-2 on Landsat 9, being built by Ball Aerospace, has completed its pre-launch characterization and calibration and is scheduled to be delivered in the summer of 2019. The TIRS-2, with improved stray light performance and increased redundancy for improved reliability, is being built by Goddard Space Flight Center. TIRS-2is undergoing testing through Spring 2019 and is also scheduled for summer2019 delivery. Several improvements to the characterization of both instruments have been incorporated into the testing plan, including improved spectral and radiometric characterization. The instruments will then be integrated onto the spacecraft being built by Northrop Grumman Innovation Systems (NGIS). The mission is targeted to launch as early as December 2020 on an Atlas V.

Landsat

An Inter-Comparison Exercise of Sentinel-2 Radiometric Validations Assessed by Independent Expert Groups

Copernicus is the European Union's Earth Observation and Monitoring programme, delivering free access to operational and historical environmental data to support applications in a wide range of societal benefit areas. To allow meaningful long-term environmental monitoring and robust decision-making, it is essential to ensure that satellite-retrieved products are of high quality and consistency. This paper describes the outputs of an international workshop on the radiometric calibration validation of the Copernicus Sentinel-2A and Sentinel-2B Multi-Spectral Instrument. A wide range of vicarious methodologies have been applied independently and then compared per type of target. All methods agree on the good radiometric performance of both Sentinel-2A and Sentinel-2B with respect to the mission requirements as well as on evidence of a slight bias between the two instruments. Comparisons of all these results are discussed to highlight the benefits and advantages of the methods as well as to propose potential improvements either for the methods themselves and/or for the comparison exercise.

Sentinel-2

Validation of GOES-17 ABI Reflective Channels Performance: Salar De Uyuni 2018 Field Campaign Results

Validation results from a reflectance-based field campaign at the Salar de Uyuni in Bolivia (September 2018) are presented for GOES-17 and GOES-16 Advanced Baseline Imagers (ABI) reflective channels. The in situ measurements were used to characterize the surface reflectance and the atmosphere in order to constrain a radiative transfer model and predict the reflectance at the top of the atmosphere (TOA), which was then compared to the ABI measurements. The field campaign provides TOA reflectance estimates over several days, allowing assessment of the calibration accuracy and stability of channels 1, 2, 3, 5 and 6 for GOES-17 andGOES-16 ABI. Channel 1 of GOES-17 ABI shows -5.5% bias in comparison to the ground-based predicted TOA. Over 6% bias in GOES-17 B2 was confirmed. A comparison to NOAA-20 VIIRS was also carried on during a near nadir overpass.

validation

Impacts of Assimilating Geostationary Infrared Sounders within NASA’s Observing System Simulation Experiment Framework

The National Oceanic and Atmospheric Administration (NOAA) has proposed including a hyperspectral infrared sounder onboard the Geostationary eXtended Observations (GeoXO) platform, scheduled to begin launching in the 2030s. A set of observing system simulation experiments (OSSEs) was preformed to investigate the impact of assimilating data from the GeoXO Sounder (GXS) using the National Aeronautics and Space Administration (NASA) Global Modeling and Assimilation Office (GMAO) OSSE system. The aim of this study is to identify the global gains achieved by the assimilation of geostationary infrared sounders from a numerical weather prediction perspective. Progress of current experimentation and future directions will be presented.

Erica Mcgrath-Spangler

Impacts of Assimilating Infrared Sounders from Geostationary Orbit

A set of observing system simulation experiments (OSSEs) was used to assess the impact of assimilating hyperspectral infrared (IR) radiances from geostationary platforms. This was done in preparation for the proposed National Oceanic and Atmospheric Administration (NOAA) Geostationary eXtended Observations (GeoXO) Sounder (GXS), expected to launch in the 2030s, using the National Aeronautics and Space Administration (NASA) Global Modeling and Assimilation Office (GMAO) OSSE framework. From a numerical weather prediction (NWP) perspective, a global “ring” of geostationary IR sounders was found to improve both the analysis and forecasts and provide beneficial impacts as measured by the forecast sensitivity observation impact (FSOI) metric.

Geostationary orbit