Engineering Papers⌕ Search

Engineering topics

Ji, Shiqi

Publications and source records attributed to Ji, Shiqi.

SiC Based Modular Transformer-less MW-Scale Power Conditioning System and Control for Flexible CHP System

This project aims at developing a SiC-based, modular, transformer-less (60-Hz-transformers-free), MW-scale, four-wire DC/AC power conditioning system (PCS) converter, and a corresponding control system for flexible-CHP (F-CHP) systems. With the help of an F-CHP controller and power electronics converters, different CHP sources, renewable sources, and batteries can be assembled to the DC grid, which is then connected to the medium voltage (MV) AC grid through the PCS converter. To meet grid support and performance requirements, the F-CHP controller design and PCS converter design follow IEEE 1547 and IEEE 2030.7 standards. Five main tasks, including PCS converter design, F-CHP controller development, PCS converter prototype building and testing, F-CHP controller testing, and PCS paralleling, have been carried out. In this project, the F-CHP controller testing has been completed in simulation, HIL and HTB, and the PCS converter prototypes have been successfully built and tested.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Inrush Current Limiting Method for Grid-Connected Converters Considering Grid Voltage Disturbances

To support the electric power grid, some grid-connected converters are required to ride through abnormal grid conditions, including voltage disturbances. However, at the moment, when a grid voltage disturbance happens, a large inrush current could be induced due to the large difference between the grid and converter output pulsewidth modulation (PWM) voltages. This inrush current could be more severe in the faster switching SiC-based multilevel converter, which only needs a small filter inductance to meet its normal operation requirements, such as harmonics and peak ripple currents. In this article, a PWM mask method is used to limit the inrush current. With this method, the inrush current can be effectively limited to a preset value and can help the converter ride through grid voltage disturbances. Furthermore, the method is validated through experiments conducted on a single-phase SiC-based five-level converter considering low voltage, high voltage, and phase angle disturbances.

42 ENGINEERING↗

The Impact of the Lightning Surge on SiC-based Medium-voltage Three-phase Four-wire Grid-connected Converters

The surge voltage induced by lightning will generate an inrush current in a grid-connected converter. It may not be large in Si-based converters because of the large grid side inductive filter. However, for SiC-based multi-level converters, the inrush current could be very large due to the small filter inductance, which is selected based on the current harmonic consideration. Most previous work focuses on system-level lightning protection while the converter-level impact, especially the internal components of the converter, is rarely discussed. This paper presents the analysis of the impact of the lightning surge on a 10 kV SiC MOSFET-based 13.8 kV three-phase four-wire grid-connected converter. The IEEE arrester model and the combined wave generator model in IEC 61000-4-5 standard are used to evaluate the inrush current, DC-link overvoltage, and component-to-ground potential of the converter. Analysis and simulation results have been provided to demonstrate the impact of lightning on the grid-connected converter. It is found that large inrush current occurs due to the small filter inductance, and the neutral-to-ground impedance impacts both the inrush current and the neutral point-to-ground potential.

Li, Haiguo↗

An Inrush Current Limit Method for SiC-based Multi-level Grid-connected Converter During Low-Voltage Ride-Through

Low-voltage ride-through is one of the grid requirements for grid-connected converters, and during the transient of grid voltage change, a large inrush current could be induced due to the control delay of the converter. This inrush current is more severe in SiC-based multi-level converters due to the small filter inductance, which is selected based on harmonics consideration. In this paper, a PWM mask method is used to limit the inrush current of a cascaded H-bridge-based grid-connected converter during the transient of grid voltage change. Simulation and experiment results are provided to validate this method.

Li, Haiguo↗

A Transformer Flux Balancing Scheme Based on Magnetizing Current Harmonic in Dual-Active-Bridge Converters

The Dual-Active-Bridge (DAB) converter transformer flux unbalance, or dc bias, could be a critical issue due to the mismatches of converter circuit parameters and control transients. In this paper, a steady-state flux balancing scheme, based on the second-order harmonic of magnetizing current has been proposed. The relationship between steady-state flux/magnetizing current unbalance and its harmonic contents has been analyzed, with which a new current sensing method and control strategy are introduced. The proposed magnetizing current sensing method can be implemented for both unity and complicated fractional turns ratios, without high sensitivity to dc offset from the analog circuitry. The proposed scheme has been validated with experimental results on 850-V/850-V DAB converters within a system, as well as in an 850-V/6700-V medium voltage DAB unit.

Gao, Zihan↗