Engineering Papers⌕ Search

Engineering topics

Jessica Koehne

Publications and source records attributed to Jessica Koehne.

Algorithmic Detection of Elemental Biosignatures

Machine learning models that classify a sample as indicative or non-indicative of life could play an important role in life-detection missions. Their predictions result from agnostic algorithms and thereby add redundancy to judgements resulting from human expertise. Additionally, their important features can reveal the most informative measurements within the operational constraints of a life-detection mission. The Ladder of Life Detection (Neveu 2018) identifies the need for an understanding of how combinations of multiple biosignatures affect overall confidence. The present work provides a starting point to answer this need, and future work will expand the data types to obtain even more predictive combinations of features. Elemental abundance was chosen as a starting set of features due to its availability in diverse sample types, which are needed to train a generalizable model. A standardized dataset was collected, including 35 non-indicative, e.g., lunar rock, basalt; 19 indicative mixed, e.g., seawater, agricultural soil; 46 indicative non-alive, e.g., coal, chalk; and 10 indicative alive, e.g., biofilm, bacteria. This dataset could be valuable for complementary biosignature research. The samples were standardized to the same limit of detection of a simulated mission scenario. Four classification models were used: k-nearest neighbors (KNN), logistic regression (LR), linear support vector machines (SVM), and Gaussian naïve Bayes (GNB). To obtain feature importances, KNN was run on three principal components of the training data and LR and SVM were run with L1 and L2 regularization. The performances and feature importances of the six model variants on 40:60 train to validation ratios were assessed with Monte Carlo simulations. ROC AUC and mean accuracy scores ranged between 82% - 94%, with sensitivity greater than specificity. For indicative of life predictors, all models had C and Ca as strong and Cl as medium; a majority of models had N, K, and P as medium. For non-indicative of life predictors, all models had Si as strong, and a majority of models had Mg, Al, and Ti as medium. Varied elements were Fe (slightly non-indicative), H (slightly indicative), O (widely varied), Na, Mn, and S. These results serve as a proof of concept and suggest important elemental signals beyond merely the CHNOPS of Earth-based life.

Algorithmic↗

Autonomous Measurement of Electrochemical Redox Couples for In-Situ Characterization of Enceladus Plume Samples

A 3D-printed microfluidic electrochemical cell with integrated electrodes was developed to demonstrate autonomous in-situ electrochemical characterization of terrestrial seawater samples. The system is designed to extend the capabilities of the 2008 Phoenix Lander’s Wet Chemistry Laboratory (WCL) that analyzed the soluble chemistry of the Martian soil, by miniaturizing its fluidic architecture for analysis of µL-volume samples as expected from an Enceladus fly-by mission. The microfluidic device has a total fluid volume of 48 µL and includes dual channels each populated with 7 electrodes. Measurement of pH was measured using an iridium oxide electrode. Cyclic voltammetry with Au, Pt, and glassy carbon working electrodes was used to measure redox couples in synthetic seawater that contained inorganic and bio-organic molecules. Glassy carbon was found to have minimal risk of interference from constituents of synthetic seawater when measuring molecular organic redox species; however, care must be used to prevent interference due to potential oxidation or dissolution in the case of Au working electrodes. A completely autonomous end-to-end run including sample delivery was performed, to demonstrate the feasibility of microfluidic-based cyclic voltammetry measurements for in-situ characterization of redox couples in Ocean World samples.

Planetary Instruments↗

Electrochemical Life Detection Methods for Ocean World Exploration

Ubiquitous across terrestrial life is cellular machinery that allows chemical energy flow by facilitating and regulating electron-transfer and chemical modification pathways. Key classes of energy transport molecules enable this movement of electrons for a variety of biological purposes. Additionally, biological enzymes function to add or remove functional groups such asphosphate moieties to redox biomolecules. Presumably, extraterrestrial life is likely to rely on similar energy transport mechanisms. With the search for life in our solar system focused on the icy satellites of Jupiter and Saturn, Europa and Enceladus, developing instrumentation capable of measuring electrochemical redox signatures representative of biomolecules or enzymatic activity in seawater appears a promising and novel means of life detection. Here, we report our adaptation of the Mars Phoenix Wet Chemistry Laboratory (WCL) electroanalytical voltammetry capabilities to assay life-critical redox molecules in synthetic seawater representative of a saline alkaline solution similar to what has been predicted from the Cassini mission data of Enceladus’ sub-surface ocean. In addition, we employ a well-established electrochemical assay that indicates phosphatase activity by comparing substrate and product redox signatures. Our study demonstrated a 10 nM limit of detection for biological redox molecules and a 3 aM limit of detection for alkaline phosphatase in seawater. Incorporation of these methods into next generation WCL payloads aimed at ocean world life detection will enable the search for biological redox-active species and enzymatic activity as indicators of life.

planetary instruments↗

Monitoring Biomarkers for Muscular Atrophy using an Electronic Chip for Astronaut Health

Skeletal muscle atrophy is a serious health problem for astronauts in long-duration space flight under microgravity conditions. Preventative measures against muscle atrophy require specific exercise and dietary regimens. Preemptive measurements to improve treatment have the potential to streamline these regimens, decreasing their daily footprint and increasing astronaut quality of life. The objective of our proposed project is to (1) develop a fully integrated disposable microelectrode array chip (with the size of a stamp) that can be interfaced with a handheld electronic system for simultaneous detection of the a panel of biomarkers to monitor the progression of skeletal muscle atrophy due to disuse under microgravity in long-duration spaceflights; and (2) use such quantitative information to guide the combined countermeasures of physical exercise and pharmaceuticals (i.e. specific protease inhibitors) so that the intensity, duration and frequency of exercise can be reduced.

Biosensing↗

Printed Flexible Sensors for NASA Applications

As human spaceflight pushes beyond Low Earth Orbit (LEO), resupply of consumables becomes a significant challenge. One solution to this problem is In-Space Manufacturing (ISM), the capability to perform on-demand manufacturing and repair of consumables in an in-space environment. ISM offers significant flexibility to missions as it allows for a high degree of tailorability and reduction in launch mass. Leveraging advancements in fabrication, repair and recycling, ISM provides a highly sustainable and affordable solution to Exploration mission operations and logistics. In this talk, advances in printed electronics and sensors, ranging from nanomaterial ink development and hands-free fabrication methodologies to devices will be presented. Applications presented will include sensors for crew health monitoring, structural health monitoring and power generation.

sensors↗

Enhancing the Sensitivity of Redox Detection in Search-for-Life Missions Using Chemical Vapor Deposition (CVD) Graphene Electrodes

The primary objective for this effort is to fabricate and characterize redox-active molecules using CVD graphene as working electrodes using standard "on-chip" lithographic techniques. We then plan to move away from “on-chip” graphene electrodes and study methods for CVD graphene transfer that can also accommodate in-space manufacturing (ISM), enabling the use of this technology for crewed mission operations of the future.

graphene↗

On-Demand Manufacturing of Electronics for Space Missions

Not only does space have a different operating environment than Earth, it also has very limited material and equipment resources, requiring a manufacturing strategy tailored to the mission environment. The conventional approaches of manufacturing on Earth and delivering to space is time-consuming and costly, so In-Space Manufacturing that utilize materials from the mission site and additive manufacturing methods that offers high resource efficiency and customizability are becoming more important. NASA’s On-Demand Manufacturing of Electronics (ODME) team develops manufacturing and application strategies of various functional devices optimized for mission environments.

In Space Manufacturing↗