Engineering Papers⌕ Search

Engineering topics

Jelinsky, Patrick

Publications and source records attributed to Jelinsky, Patrick.

22 records · Page 2

An extreme ultraviolet telescope with no soft X-ray response

While EUV grazing incidence telescopes of conventional design exhibit a substantial X-ray response as well as an extreme UV response, and existing bandpass filters for the transmission of radiation longward of 400 A also transmit soft X-rays, the grazing incidence telescope presented suppresses this soft X-ray throughput through the incorporation of a Wolter Schwarzschild Type II mirror with large graze angles. The desirable features of an EUV photometric survey telescope are retained. An instrument of this design will be flown on the EUE mission, in order to make a survey of the sky at wavelengths longer than 400 A.

Finley, David S.↗

A Penning discharge source for extreme ultraviolet calibration

A Penning discharge lamp for use in the calibration of instruments and components for the extreme ultraviolet has been developed. This source is sufficiently light and compact to make it suitable for mounting on the movable slit assembly of a grazing incidence Rowland circle monochromator. Because this is a continuous discharge source, it is suitable for use with photon counting detectors. Line radiation is provided both by the gas and by atoms sputtered off the interchangeable metal cathodes. Usable lines are produced by species as highly ionized as Ne IV and Al V. The wavelength coverage provided is such that a good density of emission lines is available down to wavelengths as short as 100A. This source fills the gap between 100 and 300A, which is inadequately covered by the other available compact continuous radiation sources.

Finley, David S.↗

Calibration of a 1 meter diameter normal incidence extreme ultraviolet telescope/spectrometer

A 1-meter normal incidence telescope, with a normal incidence concave diffraction grating spectrometer at its focus, has been developed. The instrument's spectral coverage is 350 to 1150A with a spectral resolution of 5A and a peak effective area of 6 sq cm at 500A. The instrument was launched on an Aries sounding rocket on November 27, 1983 in an effort to determine the hydrogen and helium abundance in the local interstellar medium. A description of this instrument, with the primary emphasis on the methods used to calibrate it, is presented.

Jelinsky, Patrick↗

Calibration of the thin film filters to be used on the Extreme Ultraviolet Explorer Satellite

The methods of calibrating the filters used on the Extreme Ultraviolet Explorer (EUVE) astronomical satellite are described. EUVE will conduct the first all-sky survey in the entire EUV band. The measurement of the filters' transmission properties from the soft X-ray to the far UV using a grazing incidence monochromator is discussed. A particle ingress test to determine the ability of the filters to inhibit energetic particles in earth orbit from entering the detector and increasing the background is described. Problems encountered in calibrating these four filters are also presented.

Vallerga, John↗