Publications and source records attributed to Jelinsky, P..

Overview of the Fiber System for the Dark Energy Spectroscopic Instrument

The Dark Energy Spectroscopic Instrument (DESI) is a revolutionary instrument designed for precise measurements of cosmic distances and the investigation of dark energy. DESI utilizes 5000 optical fibers to simultaneously measure the spectra of distant objects and aims to measure 40 million galaxies and quasars in a 5 yr survey. One of the critical challenges to DESI's success was ensuring that the fiber system was not only highly efficient but also delivered a highly stable beam enabling more reliable sky subtraction for measurements of faint objects. We achieved this stability by minimizing the stress on the fiber system during the manufacture and operation of the telescope and fiber positioning robots. We installed the DESI fiber system on the 4 m Mayall telescope with ≥99% of fibers intact, and the instrument has delivered superb optical performance throughout the initial years of the DESI survey, including ≥90% average throughput when injected with a focal ratio of ~f/3.9 as delivered by the primary focus corrector, excluding fiber absorption losses. The design of DESI required multiple innovations to achieve these requirements, such as cleaved fibers bonded with a UV-curing epoxy to glass ferrules in the focal plane and fusion splicing instead of physical connectors. In this paper, we describe the development, delivery, and installation of the fiber system, the innovations that made the state-of-the-art performance possible, and the key lessons learned that could benefit future projects.

79 ASTRONOMY AND ASTROPHYSICS

Microchannel Plates for the UVCS and SUMER Instruments on the SOHO Satellite

The microchannel plates for the detectors in the SUMER (Solar Ultraviolet Measurements of Emitted Radiation) and UVCS (Ultraviolet Coronograph Spectrometer) instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in late 1995 are described. A low resistance Z stack of microchannel plates (MCP's) is employed in a detector format of 27 mm x 10 mm using a multilayer cross delay line anode (XDL) with 1024 x 360 digitized pixels. The MCP stacks provide gains of greater than 2 x 10(exp 7) with good pulse height distributions (as low as 25% FWHM) under uniform flood illumination. Background rates of approx. 0.6 event cm(exp -2) sec(exp -1) are obtained for this configuration. Local counting rates up to about 800 events/pixel/sec have been achieved with little drop of the MCP gain. MCP preconditioning results are discussed, showing that some MCP stacks fail to have gain decreases when subjected to a high flux UV scrub. Also, although the bare MCP quantum efficiencies are close to those expected (10%), we found that the long wavelength response of KBr photocathodes could be substantially enhanced by the MCP scrubbing process. Flat field images are characterized by a low level of MCP fixed pattern noise and are stable. Preliminary calibration results for the instruments are shown.

Siegmund, O. H. W.

Delay Line Detectors for the UVCS and Sumer Instruments on the SOHO Satellite

Microchannel plate based detectors with cross delay line image readout have been rapidly implemented for the SUMER and UVCS instruments aboard the Solar Orbiting Heliospheric Observatory (SOHO) mission to be launched in July 1995. In October 1993 a fast track program to build and characterize detectors and detector control electronics was initiated. We present the detector system design for the SOHO UVCS and SUMER detector programs, and results from the detector test program. Two deliverable detectors have been built at this point, a demonstration model for UVCS, and the flight Ly alpha detector for UVCS, both of which are to be delivered in the next few weeks. Test results have also been obtained with one other demonstration detector system. The detector format is 26mm x 9mm, with 1024 x 360 digitized pixels, using a low resistance Z stack of microchannel plates (MCP's) and a multilayer cross delay line anode (XDL). This configuration provides gains of approximately 2 x 10(exp 7) with good pulse height distributions (less than 50% FWHM) under uniform flood illumination, and background levels typical for this configuration (approximately 0.6 event cm (exp -2)sec(exp -1)). Local counting rates up to about 400 events/pixel/sec have been achieved with no degradation of the MCP gain. The detector and event encoding electronics achieves about 25 millimeter FVHM with good linearity (plus or minus approximately 1 pixel) and is stable to high global counting rates (greater than 4 x 10(exp 5) events sec(exp -1)). Flat field images are dominated by MCP fixed pattern noise and are stable, but the MCP multifiber modulation usually expected is uncharacteristically absent. The detector and electronics have also successfully passed both thermal vacuum and vibration tests.

Seigmund, O. H. W.

Extreme Ultraviolet Explorer observations of the RS Canum Venaticorum systems AR Lacertae and II Pegasi

We report observations of two RS CVn systems, II Peg and AR Lac, which were calibration targets during the in-orbit checkout phase of the Extreme Ultraviolet Explorer (EUVE). We have determined count rates, and, based on these count rates, preliminary emission measure analyses have been done. The Lexan/boron band count rates were 0.0849 +/- 0.0023 counts/s for AR Lac and 0.218 +/- 0.031 counts/s for II Peg during its quiescent state. Temperatures and emission measures derived from the EUVE data are consistent with previously published values. We also report a flare seen during the II Peg observations which has characteristics similar to previously observed flares on II Peg. During the flare the Lexan/boron count rate increased by at least a factor of 2.5, and the minimum total duration was about 34,000 s (about 9.4 hr).

Petterer, R. J.

The EUVE proposal database and scheduling system

The proposal database and scheduling system for the Extreme Ultraviolet Explorer will be described. The proposal database has been implemented to take input for approved observations selected by the EUVE Peer Review Panel and output target information suitable for the scheduling system to digest. The scheduling system is a hybrid of the SPIKE program and EUVE software which checks spacecraft constraints, produces a proposed schedule and selects spacecraft orientations with optimal configurations for acquiring star trackers, etc. This system has been used to schedule the In Orbit Calibration activities that took place this summer, following the EUVE launch in early June 1992. The implemented strategy has implications for the selection of approved targets, which have impacted the Peer Review process. In addition, it will be discussed how the proposal database, founded on Sybase, controls the processing of EUVE Guest Observer data.

Christian, C.

Expected scientific performance of the three spectrometers on the extreme ultraviolet explorer

The expected in-orbit performance of the three spectrometers included on the Extreme Ultraviolet Explorer astronomical satellite is presented. Recent calibrations of the gratings, mirrors and detectors using monochromatic and continuum EUV light sources allow the calculation of the spectral resolution and throughput of the instrument. An effective area range of 0.2 to 2.8 sq cm is achieved over the wavelength range 70-600 A with a peak spectral resolution (FWHM) of 360 assuming a spacecraft pointing knowledge of 10 arc seconds (FWHM). For a 40,000 sec observation, the average 3 sigma sensitivity to a monochromatic line source is 0.003 photons/sq cm s. Simulated observations of known classes of EUV sources, such as hot white dwarfs, and cataclysmic variables are also presented.

Vallerga, J. V.

Synchrotron radiation calibration of the EUVE variable line-spaced diffraction gratings at the NBS SURF II facility

The Extreme Ultraviolet Explorer (EUVE) has a spectrometer which utilizes variable line-spaced, plane diffraction gratings in the converging beam of a Wolter-Schwarzschild type II mirror. The gratings, microchannel plate detector, and thin film filters have been calibrated with continuum radiation provided by the NBS SURF II facility. These were calibrated in a continuum beam to find edges or other sharp spectral features in the transmission of the filters, quantum efficiency of the microchannel plate detector, and efficiency of the gratings. The details of the calibration procedure and the results of the calibration are presented.

Jelinsky, P.

Calibration of photon counting imaging microchannel plate detectors for EUV astronomy

The calibration of photon counting imaging detectors for satellite based EUV astronomy is a complex process designed to ensure the validity of the data received 'in orbit'. The methods developed to accomplish calibration of microchannel plate detectors for the Extreme Ultraviolet Explorer are described and illustrated. The characterization of these detectors can be subdivided into three categories: stabilization, performance tests, and environmental tests.

Siegmund, O. H. W.

Proposed design class of grazing incidence echelle spectrometers - Critical analysis and reevaluation

The class of miltibounce grazing spectrometers proposed by Cash (1982) and by McClintock and Cash (1982) is analyzed, and performance values significantly lower than asserted by these authors are found. Ray tracing calculations used to examine the design parameters given in the above papers are reported, as is the efficiency which results from use of accepted reflectance data. Several schemes which can improve some of the performance parameters are indicated.

Hettrick, M. C.

Extreme UV measurements of a varied line-space Hitachi reflection grating - Efficiency and scattering

The first extreme UV measurements of a grating mechanically ruled with smooth variations in the grating constant are presented. The grating characteristics are summarized and a schematic of the testing apparatus is shown and described. The procedure for obtaining the absolute grating efficiency is given. The results for that efficiency as a function of wavelengths of 68, 170, 256, 304, 584, and 1216 A are reported and discussed. Efficiency measurements were also made as a function of position across the ruled width at 256 A and 87 deg incident angle, and the results are discussed. Scattering measurements performed via computer acquisition of diffracted image profiles are reported.

Edelstein, J.

Rocket observations of the diffuse ultraviolet background

The objective of the experiment reported here was to obtain additional information on the absolute intensity level and spatial variation of the diffuse ultraviolet background and thereby gain insight into the origin of this radiation. The experiment used three ultraviolet sensitive photometers placed in the focal plane of a 95-cm, f/2.8 normal incidence telescope flown on board an Aries sounding rocket. The measured intensities clearly refute the hypothesis of an isotropic background, the intensities of the high galactic latitude being definitely lower than the intensities seen at intermediate latitudes. Moreover, the count rates in all three channels along the slow scan exhibit local enhancements as well as an overall trend. In general, the spatial variations exhibited by the data correlate with the line of sight of neutral hydrogen column density as determined from 21-cm radio observations. This fact demonstrates that there is a galactic component to the diffuse ultraviolet radiation field.

Jakobsen, P.

Composite thin-foil bandpass filter for EUV astronomy Titanium-antimony-titanium

Thin metallic foils of antimony and titanium have been investigated in an attempt to develop an EUV filter with a bandpass from 350 to 550 A. A composite filter has been developed composed of antimony sandwiched between two titanium foils. The transmissions of sample composite foils and of pure titanium foils from 130 to 1216 A are presented. The absorption coefficients of anatimony and titanium and the effect of titanium oxide on the transmission are derived. The composite filter has been found to be quite stable and mechanically rugged. Among other uses, the filter shows substantial promise for EUV astronomy.

Jelinsky, P.

Development of a 1m-normal-incidence-EUV-Telescope

A brief description is given of the 1m-EUV-Telescope and its focal plane instrumentation, namely an EUV spectrometer and six EUV/FUV photometers. The telescope is scheduled for launch on an Aries rocket on June 17, 1982. The principal goals are the white dwarf HZ43 and a photometric scan across the sky in an area of the sky where 21 cm line observations reveal a steep density gradient. The optical bench of the telescope is a cylinder made of a graphite epoxy compound. Despite its low specific weight, the bench shows an excellent mechanical performance, with an elasticity modulus of approximately 70,000 N/cu mm. It is pointed out that by carefully combining layers with different winding angles of the carbon fiber, the thermal expansion along the cylinder axis is almost negligible, even under severe thermal loads

Grewing, M.

Wedge-and-strip anodes for centroid-finding position-sensitive photon and particle detectors

The paper examines geometries employing position-dependent charge partitioning to obtain a two-dimensional position signal from each detected photon or particle. Requiring three or four anode electrodes and signal paths, images have little distortion and resolution is not limited by thermal noise. An analysis of the geometrical image nonlinearity between event centroid location and the charge partition ratios is presented. In addition, fabrication and testing of two wedge-and-strip anode systems are discussed. Images obtained with EUV radiation and microchannel plates verify the predicted performance, with further resolution improvements achieved by adopting low noise signal circuitry. Also discussed are the designs of practical X-ray, EUV, and charged particle image systems.

Martin, C.

Filter development for the extreme ultraviolet explorer

Thin film filters with extreme ultraviolet bandpasses unattainable with previously available filter materials were developed. Titanium and antimomy were identified as the most promising materials for providing the scientifically important 350-500 A bandpass heretofore unattainable with thin film filters. Titanium foils and titanium-antimony sandwich foils of the required uniformity and durability were fabricated. Transmission measurements and optimization studies indicate that the titanium-antimony combination provides an ideal bandpass for scientifically valuable, high-sensitivity observations with EUVE. Environmental testing of the mechanical strength, moisture sensitivity and aging characteristics of the newly developed filter materials demonstrate flightworthy performance.

Kimble, R.