Engineering Papers⌕ Search

Engineering topics

Jeffery J Kolodziejczak

Publications and source records attributed to Jeffery J Kolodziejczak.

X-Ray Polarized View of the Accretion Geometry in the X-Ray Binary Circinus X-1

Cir X-1 is a neutron star X-ray binary characterized by strong variations influx during its eccentric∼16.6 day orbit. There are also strong variations in the spectral state, and it has historically shown both atoll and Z state properties. We observed the source with the Imaging X-ray Polarimetry Explorer during two orbital segments, 6days apart, for a total of 263 ks. We find an X-ray polarization degree in these segments of 1.6%±0.3% and1.4%±0.3% at polarization angles of 37°±5°and−12°±7°, respectively. Thus, we observed a rotation of the polarization angle by 49°±8°along the orbit. Because variations of accretion flow, and then of the hardness ratio, are expected during the orbit, we also studied the polarization binned in hardness ratio and found the polarization angle differing by 67°±11°between the lowest and highest values of the hardness ratio. We discuss possible interpretations of this result that could indicate a possible misalignment between the symmetry axes of the accretion disk and the Comptonizing region caused by the misalignment of the neutron star’s angular momentum with respect to the orbital one.

Sco-X-1↗

Toward Large-Area Sub-Arcsecond X-Ray Telescopes II

In order to advance significantly scientific objectives, future x-ray astronomy missions will likely call for x-ray telescopes with large aperture areas (approx. = 3 sq m) and fine angular resolution (approx. = 1"). Achieving such performance is programmatically and technologically challenging due to the mass and envelope constraints of space-borne telescopes and to the need for densely nested grazing-incidence optics. Such an x-ray telescope will require precision fabrication, alignment, mounting, and assembly of large areas (approx. = 600 sq m) of lightweight (approx. = 2 kg/sq m areal density) high-quality mirrors, at an acceptable cost (approx. = 1 M$/sq m of mirror surface area). This paper reviews relevant programmatic and technological issues, as well as possible approaches for addressing these issues-including direct fabrication of monocrystalline silicon mirrors, active (in-space adjustable) figure correction of replicated mirrors, static post-fabrication correction using ion implantation, differential erosion or deposition, and coating-stress manipulation of thin substrates.

Shi Ye↗

Kepler Instrument Performance: An In-Flight Update

The Kepler Mission is designed to detect the 80 parts per million (ppm) signal from an Earth-Sun equivalent transit. Such precision requires superb instrument stability on time scales up to 2 days and systematic error removal to better than 20 ppm. The sole scientic instrument is the Photometer, a 0.95 m aperture Schmidt telescope that feeds the 94.6 million pixel CCD detector array, which contains both Science and Fine Guidance Sensor (FGS) CCDs. Since Kepler's launch in March 2009, we have been using the commissioning and science operations data to characterize the instrument and monitor its performance. We find that the in-flight detector properties of the focal plane, including bias levels, read noise, gain, linearity, saturation, FGS to Science crosstalk,and video crosstalk between Science CCDs, are essentially unchanged from their pre-launch values. Kepler'sunprecedented sensitivity and stability in space have allowed us to measure both short- and long- term effects from cosmic rays, see interactions of previously known image artifacts with starlight, and uncover several unexpected systematics that affect photometric precision. Based on these results, we expect to attain Kepler's planned photometric precision over 90% of the field of view.

CCD↗