Aging of Palladium Tritide Foils
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Jarek, Russell L..
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In 2015, an incident released approximately 40 Ci of T 2 gas directly into the Tritium Exhaust System. Data from a bubbler system that monitored the stack effluent during the time period encompassing the accident, from 9 days prior through approximately 26 hours following the release, indicated that approximately 0.25% of the total accumulated tritium gas was in the form of tritiated water; however this value does not account for sources of tritium exhaust from other building operations and processes during the 9 days prior to this incident. Further analysis of the bubbler data around this time period considered the 9-day background contributions and shows that the actual fraction of the tritium that was released as tritiated water vapor (during and within 26 hours after the release) was likely lower than 0.1%.
Abstract not provided.
Abstract not provided.
The High Burn-Up Demonstration Project was recently initiated by the Department of Energy (DOE) to evaluate the effects of fuel drying and long term dry storage on high burn-up spent nuclear fuel. As part of the project, samples of the He backfill gas were collected 5 hours, 5 days, and 12 days after completion of drying. The samples provide information on the state of the fuel at closure, and on the environment within the cask. At Sandia National Laboratories, the samples were analyzed by gamma-ray spectroscopy to quantify fission product gases and by gas mass spectrometry to quantify bulk and trace gases; water content was measured via humidity probe. Gamma-ray spectroscopy results indicated no detectible 85 Kr, indicating no failed fuel rods were present after drying. Mass spectrometry indicated build-up of CO 2 to 930 ppmv over two weeks, attributed to oxidation of organic compounds (possibly vacuum grease or vacuum pump oil) within the cask. H 2 , generated by either radiolysis or metal corrosion, also increased up to —500 ppmv. Water contents in the cask were higher than anticipated, increasing to —17,400 ppmv ±10% after 12 days. Measuring water content proved challenging, and possible improvements to the method for future analyses are proposed.
Abstract not provided.
Abstract not provided.