Engineering PapersSearch

Engineering topics

Jain, Prashant [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)] (ORCID:0000000170552386)

Publications and source records attributed to Jain, Prashant [Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)] (ORCID:0000000170552386).

Assessing the Heat Transfer Modeling Capabilities of CFD Software for Involute-Shaped Plate Research Reactors

The ongoing efforts to convert High-Performance Research Reactors (HPRRs) using Highly Enriched Uranium (HEU) to Low-Enriched Uranium (LEU) fuel require reliable thermal–hydraulic assessments of modified core designs. The involute-shaped fuel plates used in several major HPRRs present unique modeling challenges due to their compact core geometries and high heat flux conditions. This study evaluates the capability of three commercial CFD tools, STAR-CCM+, COMSOL, and ANSYS CFX, to predict cladding-to-coolant heat transfer using Reynolds-Averaged Navier–Stokes (RANS) methods within the thermal–hydraulic regimes of involute-shaped plate reactors. Broad sensitivity analysis was conducted across a range of reactor-relevant parameters using two turbulence models (k−ϵ and k−ω SST) and different near-wall treatment strategies. The results were benchmarked against the Sieder–Tate correlation and experimental data from historic studies. The codes produced consistent results, showing good agreement with the empirical correlation of Sieder–Tate and the experimental measurements. The findings support the use of these commercial CFD codes as effective tools for assessing the thermal–hydraulic performance of involute-shaped plate HPRRs and guide future LEU core development.

CFD

Driving Economics and Reducing Risks: The Business Case for Security-by-Design in Nuclear Power

This report provides an analysis of the financial, operational, and strategic advantages of incorporating Security-by-Design (SeBD) early in the lifecycle of nuclear power plant projects. By framing security as a foundational design element rather than a late-stage add-on, owners, vendors, and operators can reduce budget overruns, strengthen regulatory compliance, and increase revenue opportunities. The report details key lifecycle phases, highlighting the strategic imperative for organizations (including project developers, investors, vendors, and regulators) to adopt SeBD. Drawing on industry estimates, real-world case studies, and comparative cost analyses, the findings underscore that even a modest upfront investment in SeBD can yield substantial long-term returns by preventing costly retrofit activities, minimizing regulatory delays, and positioning nuclear vendors for the ability to adapt in the evolving security market. By avoiding excessive retrofit expenses and positioning security as a built-in feature rather than an afterthought, nuclear projects can protect their financial performance, enhance public trust, and secure a competitive edge in an increasingly complex global energy market. The authors advocate for SeBD’s strategic implementation, supported by established quality management methodologies, thereby promoting continuous improvement and defect avoidance. Ultimately, early SeBD integration represents a strategic investment, yielding significant returns by preventing costly retrofits and positioning nuclear projects for enhanced competitiveness and public trust.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Experimental and Computational Characterization of a Modified Sioutas Cascade Impactor for Respirable Radioactive Aerosols

Oak Ridge National Laboratory is collecting and characterizing aerosols released when spent nuclear fuel (SNF) rods are fractured in bending. An aerosol collection system was designed and tested to collect respirable sized (<10 μm aerodynamic diameter [AED]) particulates inside a hot cell facility. The setup is a modified version of the commercially available Sioutas cascade impactor, to which additional stages were added to expand the aerosol collection range from 2.5 to ~15 μm AED. To accommodate the additional stages and specific test conditions, the operating flow rate for aerosol collection was reduced, and testing was conducted by using pressure drop measurements, surrogate dust collection, and particle size characterization. The fluid flow distribution within the cascade and its stages was simulated in STAR-CCM+, and the stage-wise pressure drops obtained using the computational fluid dynamics model were then compared to experimental data. Lagrangian particle simulations were also performed, and stage-wise collection statistics were obtained from the simulation for comparison with the experimental data obtained using SNF-surrogate dust particles. The results provide valuable insights into the stage-wise particle collection characteristics of the modified cascade impactor and can also be used to improve the prediction accuracy of the manufacturer-determined analytical correlations.

aerosol modeling