CT Results Using an Inverse Compton X-ray Source
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Jacob, R.
Explore the source record for details and available documents.
Purpose: Pancreas is a soft-tissue organ, implanted fiducials can change positions due to migration or tissue deformation. This study quantified positional variation of fiducials in IGRT for pancreatic cancer. Methods: 20 patients had at least 3 gold fiducials implanted in pancreas under EUS guidance. Patients had 4D-CT simulation for gated treatment. Daily gated OBI kV images (Turebeam) were used for positional alignment with fiducials for total of 25 or 28 fractions. Relative distances among 3 fiducials (d{sub 1–} {sub 2}, d{sub 1–3}, d{sub 2–3}) were measured from 4D-CT end-of-expiration phase bin; and from gated kV images in first, mid, and last fraction (n=180). Results: The median duration between implant and simulation was 11 (range 0–41) days. The median duration between simulation and first fraction was 17 (range 8–24) days. The median relative distance was 12 (range 4–78) mm for d{sub 1–2}, 24 (range 6–80) mm for d{sub 1–3}, and 19 (range 5–63) mm for d{sub 2–3}. The median deviation was 1 mm for d{sub 1–2}, d{sub 1–3}, d{sub 2–3} between simulation and first fraction, first and mid fraction, mid and last fraction (n=180). Two patients (10%) had deviation >= 5 mm (5, 11 mm) between simulation and first fraction. One patient (5%) had deviation >= 5 mm (11 mm) between first and mid fraction. No patient (0%) had deviation >= 5 mm between mid and last fraction. In all 3 cases with deviation >=5 mm, only one fiducial was significantly deviated. No clear evidence that deviation size was associated with time interval between implant and first fraction. Conclusion: Implanted gold fiducials were quite stable over time in their relative positions in pancreas. Our data suggested at least 3 fiducials are needed. In cases that one fiducial was significantly deviated in daily kV images, this fiducial should be excluded in image guidance.
Purpose Fiducial-based imaging is often used in IGRT. Traditional gold fiducial marker often has substantial reconstruction artifacts. These artifacts Result in poor image quality of DRR for online kV-to-DRR matching. This study evaluated the image quality of PEEK in DRR in static and moving phantom. Methods CT scan of the Gold and PEEK fiducial (both 1×3 mm) was acquired in a 22 cm cylindrical phantom filled with water. Image artifacts was evaluated with maximum CT value deviated from water due to artifacts; volume of artifacts in 10×10 cm in the center slice; maximum length of streak artifacts from the fiducial. DRR resolution were measured using FWHM and FWTM. 4DCT of PEEK fiducial was acquired with the phantom moving sinusoidally in superior-inferior direction. Motion artifacts were assessed for various 4D phase angles. Results The maximum CT value deviation was −174 for Gold and −24 for PEEK. The volume of artifacts in a 10x10 cm 3 mm slice was 0.369 for Gold and 0.074 cm3 for PEEK. The maximum length of streak artifact was 80mm for Gold and 7 mm for PEEK. PEEK in DRR, FWHM was close to actual (1.0 mm for Gold and 1.1 mm for PEEK). FWTM was 1.8 mm for Gold and 1.3 mm for PEEK in DRR. Barrel motion artifact of PEEK fiducial was noticeable for free-breathing scan. The apparent PEEK length due to residual motion was in close agreement with the calculated length (13 mm for 30–70 phase, 10 mm in 40–60 phase). Conclusion Streak artifacts on planning CT associated with use of gold fiducial can be significantly reduced by PEEK fiducial, while having adequate kV image contrast. DRR image resolution at FWTM was improved from 1.8 mm to 1.3 mm. Because of this improvement, we have been routinely use PEEK for liver IGRT.
Purpose: Determining the presence of mild or early disease in the lungs can be challenging and subjective. We present a rapid and objective method for evaluating lung damage in a rat model of unilateral mild emphysema based on a new approach to heterogeneity assessment. We combined octree decomposition (used in three-dimensional (3D) computer graphics) with variograms (used in geostatistics to assess spatial relationships) to evaluate 3D computed tomography (CT) lung images for disease. Methods: Male, Sprague-Dawley rats (232 ± 7 g) were intratracheally dosed with 50 U/kg of elastase dissolved in 200 μL of saline to a single lobe (n=6) or with saline only (n=5). After four weeks, 3D micro-CT images were acquired at end expiration on mechanically ventilated rats using prospective gating. Images were masked, and lungs were decomposed to homogeneous blocks of 2×2×2, 4×4×4, and 8×8×8 voxels using octree decomposition. The spatial variance – the square of the difference of signal intensity – between all pairs of the 8×8×8 blocks was calculated. Variograms – graphs of distance vs. variance - were made, and data were fit to a power law and the exponent determined. The mean HU values, coefficient of variation (CoV), and the emphysema index (EI) were calculated and compared to the variograms. Results: The variogram analysis showed that significant differences between groups existed (p<0.01), whereas the mean HU (p=0.07), CoV (p=0.24), and EI (p=0.08) did not. Calculation time for the variogram for a typical 1000 block decomposition was ∼6 seconds, and octree decomposition took ∼2 minutes. Decomposing the images prior to variogram calculation resulted in a ∼700x decrease in time as compared to other published approaches. Conclusions: Our results suggest that the approach combining octree decomposition and variogram analysis may be a rapid, non-subjective, and sensitive imaging-based biomarker for quantitative characterization of lung disease.
Abstract Not Provided