Engineering PapersSearch

Engineering topics

Jacob, D.J.

Publications and source records attributed to Jacob, D.J..

Precision Requirements for Space-based XCO2 Data

Precision requirements have been determined for the column-averaged CO2 dry air mole fraction (X(sub CO2)) data products to be delivered by the Orbiting Carbon Observatory (OCO). These requirements result from an assessment of the amplitude and spatial gradients in X(sub CO2), the relationship between X(sub CO2) precision and surface CO2 flux uncertainties calculated from inversions of the X(sub CO2) data, and the effects of X,,Z biases on CO2 flux inversions. Observing system simulation experiments and synthesis inversion modeling demonstrate that the OCO mission design and sampling strategy provide the means to achieve the X(sub CO2) precision requirements. The impact of X(sub CO2) biases on CO2 flux uncertainties depend on their spatial and temporal extent since CO2 sources and sinks are inferred from regional-scale X(sub CO2) gradients. Simulated OCO sampling of the TRACE-P CO2 fields shows the ability of X(sub CO2) data to constrain CO2 flux inversions over Asia and distinguish regional fluxes from India and China.

Miller, C. E.

Evaluation of GOME Satellite Measurements of Tropospheric NO2 and HCHO using Regional Data from Aircraft Campaigns in the Southeastern United States

We compare tropospheric measurements of nitrogen dioxide (NO2) and formaldehyde (HCHO) from the Global Ozone Monitoring Experiment (GOME) satellite instrument with in situ measurements over eastern Texas and the southeast United States. On aveiage, the GOME and in situ measurements of tropospheric NO2 and HCHO columns are consistent despite pronounced sampling differences. The geometric mean in situ to GOME ratios over the campaign are 1.08 for NO2 and 0.84 for HCHO, with corresponding geometric standard deviations of 1.27 and 1.38. The correlation of the observed column spatial variability between the two NO2 measurement sets is encouraging before (r2 = 0.54, n = 18) and after (r2 = 0.67, n = 18) correcting for a sampling bias. Mean relative vertical profiles of HCHO and NO2 calculated with a global three-dimensional model (GEOS-CHEM) and used in the GOME retrieval are highly consistent with in situ measurements; differences would affect the retrieved NO2 and HCHO columns by a few percent. GOME HCHO columns over eastern Texas include contributions from anthropogenic volatile organic compound (VOC) emissions but are dominated by biogenic VOC emissions at the regional scale in August-September when HCHO columns are within 20% of those over the southeastern United States. In situ measurements show that during summer the lowest 1500 m (the lower mixed layer) contains 75% of the tropospheric NO2 column over Houston and Nashville, and 60% of the HCHO column over Houston. Future validation of space-based measurements of tropospheric NO2 and HCHO columns over polluted regions should include coincident in situ measurements that span the entire satellite footprint, especially in the heterogeneous mixed layer.

Martin, R. V.