Engineering Papers⌕ Search

Engineering topics

Ivanov, V V

Publications and source records attributed to Ivanov, V V.

Study of the precursor and non-precursor implosion regimes in wire array Z-pinches

Star-like and closely spaced nested wire array configurations were investigated in precursor and non-precursor implosions. Closely spaced nested cylindrical arrays have inner and outer arrays with equal wire numbers, and inner and outer wires aligned to each other. The gap between the outer and inner wires is not more than 1 mm. Calculation of magnetic fields shows that the small gap results in a reversed, outward j Multiplication-Sign B force on the inner wires. Closely spaced arrays of 6-16 wires with outer diameter of 16 mm and with gaps of {Delta}R = 0.25-1 mm were tested. 6-8-wire arrays with a gap of {Delta}R = 0.4-1 mm imploded without precursor, but precursor was present in loads with 12-16 wires and {Delta}R = 0.25-1 mm. Implosion dynamics of closely spaced arrays was similar to that of star-like arrays. Implosion time was found to decrease with decreased wire numbers. Star array configurations were designed with a numerical scheme to implode with or without precursor. The lack of precursor resulted in a marginal improvement in total x-ray yield and power, and up to 20% increase in Al K-shell yield. The Al K-shell radiated energy was found to increase with decreasing the number of arrays in closely spaced and star-like wire arrays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-driven relativistic electron beam interaction with solid dielectric

The multi-frames shadowgraphy, interferometry and polarimetry diagnostics with sub-ps time resolution were used for an investigation of ionization wave dynamics inside a glass target induced by laser-driven relativistic electron beam. Experiments were done using the 50 TW Leopard laser at the UNR. For a laser flux of {approx}2 Multiplication-Sign 10{sup 18}W/cm{sup 2} a hemispherical ionization wave propagates at c/3. The maximum of the electron density inside the glass target is {approx}2 Multiplication-Sign 10{sup 19}cm{sup -3}. Magnetic and electric fields are less than {approx}15 kG and {approx}1 MV/cm, respectively. The electron temperature has a maximum of {approx}0.5 eV. 2D interference phase shift shows the 'fountain effect' of electron beam. The very low ionization inside glass target {approx}0.1% suggests a fast recombination at the sub-ps time scale. 2D PIC-simulations demonstrate radial spreading of fast electrons by self-consistent electrostatic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fountain effect of laser-driven relativistic electrons inside a solid dielectric

Ultrafast interferometry with sub-ps resolution has been applied for the direct measurement of an electron density induced by a laser-driven relativistic electron beam inside a solid dielectric. The topology of the interference phase shift shows the signature of the ''fountain effect,'' a narrow electron beam that fans out from the propagation axis and heads back to the target surface. Two-dimensional particle-in-cell (PIC) computer simulations demonstrate radial spreading of fast electrons by self-consistent electrostatic fields. The very low ionization, {approx}0.1%, observed after the heating pulse suggests a fast recombination at the sub-ps time scale.

36 MATERIALS SCIENCE↗

Measurement of the Ionization State and Electron Temperature of Plasma during the Ablation Stage of a Wire-Array Z Pinch Using Absorption Spectroscopy

Wire-array plasmas were investigated in the nonradiative ablation stage via x-ray absorption spectroscopy. A laser-produced Sm plasma was used to backlight Al wire arrays. The Sm spectrum was simultaneously observed by two spectrometers: one recorded the unattenuated spectrum and the other the transmission spectrum with 1.45-1.55 keV K-shell absorption lines. Analysis of absorption spectra revealed electron temperature in the range of 10-30 eV and the presence of F-, O-, N- and C-like Al ions in the absorbing plasma. A comparison of this electron temperature with the postprocessed absorption spectra of a 2D MHD simulation yields results in general agreement with the data analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of transparent and nontransparent regimes of implosion in star wire arrays

Star wire arrays were used to control the imploding plasma flows and study plasma interpenetration. These arrays consisted of linear 'rays' aligned azimuthally and extending from the vertical axis. Star arrays with two close located wires ('gates') instead of a single wire on the inner cylinder were studied for transparent and nontransparent regimes of propagation of imploding plasma through the gates. Nontransparent mode of collision is typical for regular star wire arrays and it was also observed in Al stars with gate wires of regular length and with the gate width of 0.3-2 mm. The cascade process of implosion in stars and trapping of imploding plasma in 1-2 mm gates were modeled with the three-dimensional resistive magnetohydrodynamics code. The intermediate semitransparent mode of collision was observed in Al stars with long Al 'gate' wires. A transparent mode was observed in Al stars with long stainless steel or W gate wires. Applications of wire arrays with controlled plasma flows are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aerosol-Assisted Solid Debris Collection for the National Ignition Facility

The National Ignition Facility (NIF) has been completed and has made its first shots on-target. While upcoming experiments will be focused on achieving ignition, a variety of subsequent experiments are planned for the facility, including measurement of cross sections, astrophysical measurements, and investigation of hydrodynamic instability in the target capsule. In order to successfully execute several of these planned experiments, the ability to collect solid debris following a NIF capsule shot will be required. The ability to collect and analyze solid debris generated in a shot at the National Ignition Facility (NIF) will greatly expand the number of nuclear reactions studied for diagnostic purposes. Currently, reactions are limited to only those producing noble gases for cryogenic collection and counting with the Radchem Apparatus for Gas Sampling (RAGS). The radchem solid collection diagnostic has already been identified by NIF to be valuable for the determination and understanding of mix generated in the target capsule's ablation. LLNL is currently developing this solid debris collection capability at NIF, and is in the stage of testing credible designs. Some of these designs explore the use of x-ray generated aerosols to assist in collection of solid debris. However, the variety of harsh experimental conditions this solid collection device will encounter in NIF are challenging to replicate. Experiments performed by Gary Grim et al. at Sandia National Laboratory's RHEPP1 facility have shown that ablation causes a cloud of material removed from an exposed surface to move normal to and away from the surface. This ablation is certain to be a concern in the NIF target chamber from the prompt x-rays, gamma rays, etc. generated in the shot. The cloud of ablated material could interfere with the collection of the desired reaction debris by slowing down the debris so that the kinetic energy is too low to allow implantation, or by stopping the debris from reaching the collection device entirely. Our goal is to use this primary ablation wave to our advantage, by the creation of ionized alkali metal halide salt aerosols. This technique is similar to that used by many particle accelerator groups for gas-jet transport. Ideally the salt would be ablated from a substrate, encounter the reaction debris, agglomerate, and be collected for further study. We have done studies at laser and pulsed-power facilities (Titan laser at LLNL, Trident laser at LANL, Zebra z-pinch at Nevada Terawatt Facility) evaluating the hardiness of materials for placement in the NIF target chamber, as well as testing aerosol generation by the incident x-rays generated in device shots. To test this method's potential success in the NIF environment, we have tested KCl, KI, RbI, and CsI films of 1 and 2 um linear thickness on aluminum and silicon wafer substrates in these aforementioned facilities, at varied distances. These salts do ablate in the presence of sufficient x-ray fluence. Further analysis to quantify the final ablation depth as a function of x-ray fluence is ongoing. Half of each sample was masked with a thick tungsten foil for photon opacity. KCl was the most difficult salt to ablate, from comparing the tungsten-masked side of the samples to the unmasked side of the samples. This is likely due to KCl's absorbance peak being at lower wavelengths than that of KI, {approx}160 nm vs. {approx}220 nm, respectively. Samples with and without collimation were tested to identify if any condensation of these ablated salts occurred after ablation. Visual inspection of the silicon wafer witness plates placed parallel to the direction of the incident photons showed that a vapor was deposited on the wafers next to the collimators. Further analysis with EDS in the case of the collimated samples conclusively identified the vapor as CsI. We also intend to examine samples of bare substrate exposed to the same experimental conditions for post-shot change via SEM images, optical microscopy, and atomic force microscopy (AFM). Furthermore, tests with separated isotopes may be done to reduce background contamination. When sample optimization is complete, we plan to develop a 'catcher' device for these desorbed aerosols. Current ideas include biased grids to either attract the ionized particles to the grid, or repel them towards a collection device.

36 MATERIALS SCIENCE↗

Phonon spectroscopy of submicron ceramic materials based on Ce{sub 1-x}Gd{sub x}O{sub 2-y} solid solutions

The specific features of the kinetic characteristics of subterahertz phonons in ceramic samples based on Ce{sub 1-x} Gd{sub x}O{sub 2-y} electrolyte solid solutions have been investigated in the range of liquid-helium temperatures. It has been demonstrated that the observed anomalies of the transport characteristics of thermal phonons in this system are caused by the formation of structural defects associated with the position of vacancies in the anion sublattice with respect to impurity cations. The activation energy of the two-level system {Delta} = 8.53 K has been determined from an analysis of the experimental results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Implosion dynamics and x-ray generation in small-diameter wire-array Z pinches

It is known from experiments that the radiated x-ray energy appears to exceed the calculated implosion kinetic energy and Spitzer resistive heating [C. Deeney et al., Phys. Rev. A 44, 6762 (1991)] but possible mechanisms of the enhanced x-ray production are still being discussed. Enhanced plasma heating in small-diameter wire arrays with decreased calculated kinetic energy was investigated, and a review of experiments with cylindrical arrays of 1-16 mm in diameter on the 1 MA Zebra generator is presented in this paper. The implosion and x-ray generation in cylindrical wire arrays with different diameters were compared to find a transition from a regime where thermalization of the kinetic energy is the prevailing heating mechanism to regimes with other dominant mechanisms of plasma heating. Loads of 3-8 mm in diameter generate the highest x-ray power at the Zebra generator. The x-ray power falls in 1-2 mm loads which can be linked to the lower efficiency of plasma heating with the lack of kinetic energy. The electron temperature and density of the pinches also depend on the array diameter. In small-diameter arrays, 1-3 mm in diameter, ablating plasma accumulates in the inner volume much faster than in loads of 12-16 mm in diameter. Correlated bubblelike implosions were observed with multiframe shadowgraphy. Investigation of energy balance provides evidence for mechanisms of nonkinetic plasma heating in Z pinches. Formation and evolution of bright spots in Z pinches were studied with a time-gated pinhole camera. A comparison of x-ray images with shadowgrams shows that implosion bubbles can initiate bright spots in the pinch. Features of the implosions in small-diameter wire arrays are discussed to identify mechanisms of energy dissipation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

UV Laser Diagnostics of the 1-MA Z-pinch Plasmas

The 532 nm laser diagnostic set at the Zebra generator shows the details of the ablation and stagnation phases in cylindrical, planar, and star-like wire arrays but it cannot show the structure of the stagnated z-pinch and the implosion in small diameter loads, 1-3 mm in diameter. The absorption increment and the refraction angle of the 532 nm laser, when passing through the plasma, are too great to obtain quality images. An ultraviolet probing beam at the wavelength of 266 nm was developed to study small-diameter loads and to investigate the structure of the 1-MA z-pinch. The UV radiation has a much smaller absorption increment and refraction angles in plasmas than the 532 nm light and allows for better imaging of the z-pinch plasmas. Estimates showed that UV probing would be able to probe the high-density z-pinch plasma in experiments on the Zebra generator, and the early results of UV probing on the Zebra generator have shown promise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental study of star-like and small-diameter wire-array z-pinches on the 1-MA Zebra generator

Star-like wire arrays and small-diameter (1-3 mm in diameter) cylindrical loads were tested in the 1-MA Zebra generator. Mitigation of plasma inhomogeneity was observed in the implosions of star-like loads, which consisted of multiple nested, cylindrical arrays aligned azimuthally such that the wires appear as linear array 'rays' extending from the axis of symmetry. The implosion in these loads is directed along the 'rays' of the star and cascades from wire to wire to the center to form moving plasma columns with smooth leading edges. Despite the low azimuthal symmetry, a star-like wire array produces a stable x-ray pulse with a high peak power and a short duration of 8-12-ns. This can be linked to the stabilization of instabilities due to the multiple nesting. X-ray generation and implosion dynamics in wire arrays 1-16 mm in diameter were investigated to find a transition between the regime with prevailing kinetic energy and 'non-kinetic' plasma heating. Loads 3-8 mm in diameter generate the highest x-ray power at the Zebra generator. The fall of x-ray power in 1-2-mm loads can be linked to the lack of kinetic energy. Laser probing diagnostics show the formation of 'necks' on the pinch during the bubble-like implosion. The energy balance provides the evidence of the enhanced plasma heating in z-pinches. Features of the implosions in small-diameter wire-arrays can help to identify the mechanisms of energy dissipation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neodymium-doped laser yttrium oxide ceramics

We studied mechanical, optical, and lasing parameters of neodymium-doped yttrium oxide ceramics synthesised by using a new technology involving the laser synthesis of nanopowders and their magnetic pulsed compaction. The fracture toughness of ceramics to cracks and its microhardness were measured to be K{sub IC} = 0.9-1.4 MPa m{sup 1/2} and H{sub {nu}} = 11.8 GPa, respectively. Ceramic samples sintered in the temperature range from 1550 to 2050{sup 0}C have the porosity (1-150)x10{sup -4}% and the optical loss coefficient {alpha}{sub 1.07} = 0.03-2.1 cm{sup -1} at a wavelength of 1.07 {mu}m. It is shown that such porosity does not affect the optical loss coefficient of light. Lasing at {approx}1.079 {mu}m with a slope efficiency of 15% was obtained in a 1.1-mm-thick sample pumped by laser diodes. (active media. lasers)

36 MATERIALS SCIENCE↗

Compact wire array sources: power scaling and implosion physics.

A series of ten shots were performed on the Saturn generator in short pulse mode in order to study planar and small-diameter cylindrical tungsten wire arrays at {approx}5 MA current levels and 50-60 ns implosion times as candidates for compact z-pinch radiation sources. A new vacuum hohlraum configuration has been proposed in which multiple z pinches are driven in parallel by a pulsed power generator. Each pinch resides in a separate return current cage, serving also as a primary hohlraum. A collection of such radiation sources surround a compact secondary hohlraum, which may potentially provide an attractive Planckian radiation source or house an inertial confinement fusion fuel capsule. Prior to studying this concept experimentally or numerically, advanced compact wire array loads must be developed and their scaling behavior understood. The 2008 Saturn planar array experiments extend the data set presented in Ref. [1], which studied planar arrays at {approx}3 MA, 100 ns in Saturn long pulse mode. Planar wire array power and yield scaling studies now include current levels directly applicable to multi-pinch experiments that could be performed on the 25 MA Z machine. A maximum total x-ray power of 15 TW (250 kJ in the main pulse, 330 kJ total yield) was observed with a 12-mm-wide planar array at 5.3 MA, 52 ns. The full data set indicates power scaling that is sub-quadratic with load current, while total and main pulse yields are closer to quadratic; these trends are similar to observations of compact cylindrical tungsten arrays on Z. We continue the investigation of energy coupling in these short pulse Saturn experiments using zero-dimensional-type implosion modeling and pinhole imaging, indicating 16 cm/?s implosion velocity in a 12-mm-wide array. The same phenomena of significant trailing mass and evidence for resistive heating are observed at 5 MA as at 3 MA. 17 kJ of Al K-shell radiation was obtained in one Al planar array fielded at 5.5 MA, 57 ns and we compare this to cylindrical array results in the context of a K-shell yield scaling model. We have also performed an initial study of compact 3 mm diameter cylindrical wire arrays, which are alternate candidates for a multi-pinch vacuum hohlraum concept. These massive 3.4 and 6 mg/cm loads may have been impacted by opacity, producing a maximum x-ray power of 7 TW at 4.5 MA, 45 ns. Future research directions in compact x-ray sources are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗